background image

Estimating Cartridge Life

Estimating Cartridge Life

Estimating how long a cartridge will last and the number of days between services 

is critical to performing an installation that can be serviced efficiently. This includes 

determining the number of Air/Q™ 565s needed for a space. Please refer to Pro-

litec’s ‘Sizing and Consumption Tool’ which is available from Prolitec in an electronic 

file. The chart below can be used as a rough guideline for sizing.

Room-Size Table

Output  

Level Range

Room Volume 

Range in CFT

Room Volume 

Range in m

3

1 thru 5

400 – 1,600

11 – 45

6 thru 10

2,000 – 3,400

57 – 96

11 thru 15

3,800 – 5,600

108 – 159

16 thru 20

6,000 – 7,900

170 – 224

21 thru 25

8,550 – 10,700

241 – 303

26 thru 30

11,200 – 13,700

317 – 388

31 thru 35

14,400 – 17,100

408 – 484

36 thru 40

17,900 – 21,000

507 – 595

41 thru 45

21,800 – 25,200

617 – 714

46 thru 50

26,100 – 30,000

730 – 850

These settings are suggested as a starting point. Start on the lower end of the 

range and adjust after 15-30 minutes. Fragrance type, room size, number of fresh 

air changes per hour, temperature, humidity and user preference will determine the 

final setting. Best practice is to use Prolitec’s ‘Sizing and Consumption Tool’ avail-

able from Prolitec as an electronic file. 

5

Содержание Air/Q 565

Страница 1: ...Air Q 565 User Guide Updated 15 Jan 2013 Original Instructions...

Страница 2: ...ctrical power before hardwiring an Air Q Sharp edges may cause serious injury from cuts Use care when cutting openings and handling ductwork CAUTION Do not set scent level to maximum setting or higher...

Страница 3: ...king 6 Installation 8 Starting Up 18 Features and Controls 18 Installing the Cartridge 19 Programming the Appliance 20 Setting Scent Intensity 22 Maintenance 22 Cartridge Change 22 General Care 24 Pre...

Страница 4: ...sily adjusted by the user The Air Q 565 can be installed with complete confidence in reliability and safety The patented delivery system has been proven over several years in demanding commercial envi...

Страница 5: ...blend into your heating ventilation and air conditioning system The Air Q 565 operates with air concentrations of less than 1 part per mil lion ppm This means that for every 1 000 000 molecules there...

Страница 6: ...sectors Aromatherapy and Performance Scenting It is well known that scent has a powerful impact on human emotion and behavior The use of scent to influence human emotion is just like Ambient Scenting...

Страница 7: ...CFT Room Volume Range in m3 1 thru 5 400 1 600 11 45 6 thru 10 2 000 3 400 57 96 11 thru 15 3 800 5 600 108 159 16 thru 20 6 000 7 900 170 224 21 thru 25 8 550 10 700 241 303 26 thru 30 11 200 13 700...

Страница 8: ...Switch cable 6 Two 2 Airflow Switch mounting screws 7 Mounting kit containing a mounting bracket 4 dry wall anchors 2 long mounting screws 2 short mounting screws 8 Cartridge Removal Tool 9 Two 2 spar...

Страница 9: ...Unpacking 7 1 Air Q 565 Appliance Not Pictured 2 14 13 12 11 10 9 8 7 6 5 4 3...

Страница 10: ...on the side of the air duct at a convenient location and downstream from the furnace Caution Do not mount airflow switch on return side The air flow switch and the female connector on the lower right...

Страница 11: ...Installation AIRFLOW Injector Tube Pointing with flow Sensor Tube Pointing against flow Airflow Switch Silicone Air Sensor Hose Silicone Injector Hose Air Q 565 Appliance Airflow Switch Cable 9...

Страница 12: ...te to drywall and 4 sheet metal screws suitable for attaching the mounting plate to ductwork 2 short flat head screws to attach the bracket to the wall and 2 long round head screws to secure the machi...

Страница 13: ...Installing the Top Anchors or Screws Set the mounting bracket aside Use an electric drill to make a 1 8 pilot hole at the exact location you marked This will serve as a guide for the anchors or sheet...

Страница 14: ...two bottom holes Unscrew the top screws and set the bracket aside Step 5 Installing the Bottom Anchors or Screws Drill a 1 8 pilot hole at the exact spot you marked For drywall mounting gently hammer...

Страница 15: ...e so that the big holes in the top of the back cover fit over the rounded locking posts In doing this make sure the appliance is flush with the wall and the posts are in the holes of the appliance Sli...

Страница 16: ...0 Removing the Yellow Tab Now take the appliance and pull out the yellow tab at the bottom Step 11 Installing the Airflow Switch 1 Mark locations for the screw holes using the switch as a template The...

Страница 17: ...the Injection Tube 1 Position the location of the injection tube less than 1 foot above the appliance 2 Drill a 5 8 hole in the air duct using a step drill less than 1foot above or downstream from the...

Страница 18: ...tube into free end of silicone hose Step 13 Installing the Sensor Tube 1 Position the location of the sensor tube less than 1 foot away from the airflow switch Do not install sensor tube downstream f...

Страница 19: ...4 Insert and direct metal sensor tube against air flow 5 Attach end of second silicone hose to metal sensor tube 6 Attach the other end of silicone hose to airflow switch AIRFLOW 7 Connect airflow sw...

Страница 20: ...Starting Up Air Q 565 Features and Controls Output Port Lock Air Stem Fragrance Cartridge Programming Panel 18...

Страница 21: ...Prepare cartridge by removing the top and rear plugs Do not remove front plug Rear Plug Top Output Plug Front Output Plug leave as is 2 Place the cartridge onto the white air stem 3 Close door and ins...

Страница 22: ...of the control panel AM or PM is indicated on the lower right side of the time digits 4 24 7 Mode If you want Air Q 550 to run continuously 7 days a week 24 hours a day turn the dial to Run 24 7 If n...

Страница 23: ...e minute Press the Set button to advance The rate digit now changes to E to indicate you are setting the end time Use the buttons to set the end time Press the Set button to advance to the next progra...

Страница 24: ...ent Feel free to adjust to taste Do not set scent level to maximum setting or higher than recommended in the table on page 5 but start from recommend ed lowest level and increase progressively for opt...

Страница 25: ...on the air stem for break age deterioration or swelling Replace as needed 6 If there is any leakage of fragrance during the cartridge installation clean it carefully with a paper towel and some ethano...

Страница 26: ...approved and included power supply ALWAYS mount the appliance on a wall or duct The Air Q 565 is not de signed for use on tabletops or shelves NEVER put your nose to the output of the Air Q 565 or wit...

Страница 27: ...with baking soda and allow it to set for 3 minutes before vacuuming Repeat this process up to two more times if needed If the smell of perfume persists professional cleaning may be required Spills on...

Страница 28: ...e Air Q 565 can handle spaces up to 40 000 cubic feet a 4 000 square foot space with 10 foot ceilings if oper ated 12 hours a day With 24 7 operation the Air Q 565 and a monthly cartridge change will...

Страница 29: ...65 differ from aerosol room fresheners The more expensive aerosols can produce a very pleasant scent but only for a few minutes and in very high concentrations just in the area they were sprayed Air Q...

Страница 30: ...o the fragrance doesn t drip evaporate or change while out of the Air Q 565 IMPORTANT Always keep the plugs on cartridges when not in use If you have mis placed the plugs from the cartridge being remo...

Страница 31: ...en press button to level 50 Verify that the pump inside Air Q 565 is running light appliance vibrations Check pluming after disconnecting the injector hose from the cartridge If not visible point a fl...

Страница 32: ...ting against the direction of the airflow Disconnect and join the 2 spade connectors on the air switch cable to confirm integrity of airflow switch cable This will be confirmed by the pump inside Air...

Страница 33: ...Power Supply Input 100 240V AC at 0 6A Frequency 50 60 Hz Protection Switching power supply Internal Power 12V DC at 1 5 A Battery Lithium 3V CR2032 Approvals FCC part 15 CE RoHS Compliant UL Power S...

Страница 34: ...Prolitec Incorporated 1235 W Canal Street Milwaukee WI 53223 1 866 387 4333 www airq com...

Отзывы: