background image

Beta Draft Confidential

Installing and Wiring the Thermostat

Proliphix Thermostat Installation Guide, Release 1.0

 7

Part No. 600-01000-100

Figure 2

 shows an example of a heat pump HVAC system, with reverse activate for 

heat, connecting to a Proliphix base plate.

Figure 2 Heat Pump HVAC Connections

Configuring Remote Sensors for the NT20, NT120, NT125, and 
NT150

The Proliphix thermostat provides two remote (external) sensor ports. This release 
supports Analog and Thermistor sensors (go to Proliphix.com for a complete list of 
supported sensors). 

Analog

 sensors convert temperature measurements as Fahrenheit degrees to a voltage 

which can be sensed by the thermostat. Analog sensors are active devices which 
require power from the thermostat. The Analog sensor is polarized and must be 
connected as shown in 

Table 3

Thermistor

 sensors are passive devices which represent thermal measurements as 

electrical resistance. Thermistors do not require power from the thermostat. The 
Thermistor sensor is not polarized; either lead can be connected as shown in 

Table 3

Proliphix Base Plate

Sq

uare

 Ho

le

Wire

HVAC System

Y1

W1

RH

C

1

Compressor

Auxiliary 
Heat

Reverse for
Heat

Fan 
Control

Cool & 
Heat 
Power

1.

 

Applies to “h” models only

Note: A heat pump is either a reverse for heat or reverse for cool model. Y2 (not shown in 

Figure 2

is used for reverse cool. 

W2

G

Содержание NT100e

Страница 1: ...Proliphix Thermostat Installation Guide Release 1 0 Part No 600 01000 100 April 2006...

Страница 2: ...equipment Proliphix is not liable for any claim made by a third party or made by a purchaser for a third party Proliphix shall at its option repair or replace any product found defective without charg...

Страница 3: ...nd carrier In the event that repairs are found to be non warranty return shipping charges will be paid by the purchaser FCC Model NT10e NT20e NT100e h NT120e h NT125e h NT150e h Made in the USA This d...

Страница 4: ...Beta Draft Confidential iv Proliphix Thermostat Installation Guide Release 1 0 Part No 600 01000 100...

Страница 5: ...20 60 NT20e only Two remote thermal sensors either Analog or Thermistor Single stage HVAC 1h 1c Heat pump HVAC with auxiliary heat 2h 1c NT100e h NT120e h NT125e h and NT150e h Professional Series Pow...

Страница 6: ...airwell door or window in a corner or alcove or behind an open door Install the unit after all construction work and painting is complete Install the unit in an unobstructed location where there are n...

Страница 7: ...s from the HVAC installer 4 Remove the existing thermostat from the wall Installing and Wiring the Thermostat This section describes a two step installation process in which you install or mount the t...

Страница 8: ...nal label and the corresponding Proliphix label required to support the single stage and dual stage application Table 1 Fuel Burner Terminal Conversion Chart Standard Terminal Proliphix Terminal NT10e...

Страница 9: ...into the wall 3 Using Figure 1 as a guide connect the labeled wires to the terminal post with the corresponding letter on the Proliphix base plate For example connect the wire labeled W1 to the W1 ter...

Страница 10: ...your heat pump See the user manual for your heat pump for more information Table 2 Heat Pump Terminal Conversion Chart Standard Terminal Proliphix Terminal NT10e NT20e NT100e h NT120e h NT125e h and N...

Страница 11: ...ture measurements as Fahrenheit degrees to a voltage which can be sensed by the thermostat Analog sensors are active devices which require power from the thermostat The Analog sensor is polarized and...

Страница 12: ...to the Proliphix base plate number for CAT5 CAT5E 6 color coding Table 3 Remote Sensor Port Connections Proliphix Terminal Analog Sensor Thermistor Sensora a Do not connect either lead to the S1 S2 or...

Страница 13: ...ut assignments for the T568A and T568B wiring standards Table 4 T568A and T568B Pinout Assignments Pin Number T568A Wire Color T568B Wire Color 1 Green White Orange White 2 Green Orange 3 Orange White...

Страница 14: ...an device that complies with the 802 3af Power over Ethernet standard Proliphix Ethernet Power Adapters EPA are multi port power injectors capable of supplying power to either two EPA 20 or six EPA 60...

Страница 15: ...e plate 2 Snap the bottom of the thermostat securely into the base plate Verifying the Thermostat s Operating Status This section describes the procedures you can use to verify that the heat cool and...

Страница 16: ...of the panel to select Cool 4 Press Select 5 Press Back 6 Continuously press the Down arrow until the cool set point is lower than the temperature reading The cool and fan relays should click and the...

Страница 17: ...ng is securely attached to terminal screws If using an h model thermostat Verify that the Common from the primary transformer source either RH or RC is connected to the C terminal Either RH or RC 24v...

Страница 18: ...Beta Draft Confidential 14 Proliphix Thermostat Installation Guide Release 1 0 Part No 600 01000 100 Installing and Wiring the Thermostat...

Отзывы: