background image

 

 

 

8

 

8

 

OPERATION 

After connecting batteries, AC input cables, and loads, the inverter is now ready to work. 

 
Power on/off 

Once the inverter has been properly installed, press the power switch to turn on the unit. The unit will work automatically in line mode or inverter 
mode according to input utility power’s status. When press the power switch again, the unit will be turned off. 
 

LED Indicators 

The operation mode of the inverter can be easily understood by LED indicators. Please see the table below for details. 
 

LED indicators 

Information 

 

GREEN 

Line mode 1 
(Battery is empty) 

Green flashing every 2 seconds 

Line mode 1 
(Battery is full) 

Green solid lighting 

Off-charge mode with AC 

Green flashing as cycle: 
0.5s On

0.5s Off

0.5s On

3.5s Off 

 

YELLOW 

Battery mode 
Bat low 

Yellow solid lighting 
Flashing every 2 second 

 

BLUE 

PV mode 

Blue solid lighting 

Off-charge mode with PV 

Blue flashing as cycle: 
0.5s On

0.5s Off

0.5s On

3.5s Off 

 

RED 

Overload 

Red flashing every 0.5 second 

Fault 

Red lighting 

 

Function Keys 

Function key 

Description 

ESC 

To exit setting mode 

UP 

To go to previous selection 

DOWN 

To go to next selection 

ENTER 

To confirm the selection in setting mode or enter setting mode 

 

LCD Display 
 

LCD displays the power flow and input/output readings in a visualized graphic design which allows the user to understand the operation status easily. 
The backlight of LCD remains on whenever the inverter is working (including Standby Charging Mode and Fault Mode). 
 

 

Содержание IPS Series

Страница 1: ...OFF GRID SOLAR INVERTER User Manual IPS SERIES TOWER DESKTOP WALL MOUNT IPS3003 P M IPS5003 P M 3KVA 5KVA Version 1 00 English ...

Страница 2: ...1 Table of Contents SAFETY INSTRUCTIONS 2 PRODUCT OVERVIEW 3 PRODUCT OUTLOOK 3 INSTALLATION 5 OPERATION 8 TROUBLE SHOOTING 16 SPECIFICATION 17 DIPOSAL 18 ...

Страница 3: ... not expose the product to direct sunlight rainfall or snow Before performing any maintenance on the product please disconnect all power sources AC mains batteries solar panel to avoid the risk of electrical shock Do not attempt to disassemble or repair the product Only authorized personal are allowed to perform repair While performing maintenance or cleaning especially on the batteries where haza...

Страница 4: ...nt The battery can be charged by both AC mains and PV solar string with intelligent charging control Key features Automatic line to battery switchover Built in enhanced AC charger Built in solar charger controller up to 60A Selectable input voltage ranges charging priority setting AC or solar power priority setting High efficiency DC to AC conversion with minimized energy loss Rack design wall mou...

Страница 5: ...8 4 Rear Panel 1 DC input terminals 2 AC input terminals 3 AC output terminals 4 PV input terminals 5 AC input breaker 6 Power on off button 7 RS 232 communication port ...

Страница 6: ...elow so that the inverter can be hung on the screws recommended screw size is M4 50 65mm After mounting the inverter make sure it s firmly mounted and won t easily fall off in the event of unexpected earthquake or vibration Batteries Determine the size of battery The inverter is designed with pre set charging current and voltage Given a fixed charging current under sized batteries may shorten the ...

Страница 7: ...four 12V batteries in series to make up 48V for 5000VA model PV solar string Selection of PV Panel PV string is a connection of PV panels whose output voltage and current vary under different illumination And just like battery the PV panel can be connected in either series or parallel as per needed Please consult the supplier or PV panel so that the operational voltage and current fall within the ...

Страница 8: ... off AC input voltage range selector NARROW setting Configure LCD to NARROW when connected with loads which are more sensitive on voltage range With this setting the inverter is more sensitive to the voltage disturbance on the AC input and input voltage range is set at 170 280VAC while output voltage follows input voltage WIDE setting Configure LCD to WIDE when connected with loads which are less ...

Страница 9: ...ll Green solid lighting Off charge mode with AC Green flashing as cycle 0 5s On 0 5s Off 0 5s On 3 5s Off YELLOW Battery mode Bat low Yellow solid lighting Flashing every 2 second BLUE PV mode Blue solid lighting Off charge mode with PV Blue flashing as cycle 0 5s On 0 5s Off 0 5s On 3 5s Off RED Overload Red flashing every 0 5 second Fault Red lighting Function Keys Function key Description ESC T...

Страница 10: ...Indicates input output PV and battery information Battery Level Indicates battery level in battery mode and charging status Load level Indicates the load level LCD Setting When the power switch is turned on pressing and holding ENTER button immediately for 3 seconds the unit will into the setting mode Press UP or DOWN button to select setting programs And then press ENTER button to confirm the sel...

Страница 11: ...wer is not available default If setting SOL priority solar energy will provide power to loads as first priority If solar energy is not sufficient to power all connected loads battery energy will supply power to the loads at the same time Utility provides power to the loads only when any one condition happens Solar energy is not available Battery voltage drops to the low level warning voltage or th...

Страница 12: ...able options in 5000VA model 44 0 45 46 47 48 49 50 51V ESC 23V for 3000VA 46V for 5000VA Unit works in PV mode if solar power is not sufficient to supply loads the battery will power loads at the same time When battery voltage drops to the setting voltage point unit will transfer to utility mode Setting voltage point back to battery mode when selecting SBU or SOLAR FIRST Note This setting voltage...

Страница 13: ...ESC Any Utility power come back after inverter shut down at battery low condition the inverter will auto restart if battery voltage is charging up to setting point Battery shutdown voltage setting Available options in 3000VA model 20 0 20 4 20 8 21 2 21 6 22 0V ESC Available options in 5000VA model 40 0 40 8 41 6 42 4 43 2 44 0V ESC 21 2V for 3000VA 42 4V for 5000VA Setting range is from 20 0V to ...

Страница 14: ...isplay Standby charging mode Battery can be charged without switching on the unit Utility input bypass to output and charge the battery Battery is charging by PV energy only no AC output Utility input bypass to output and charging by both utility and PV ...

Страница 15: ...e charged when switching on the unit Utility input bypass to output and battery can be charged by both utility and PV when switching on the unit Battery mode The backup power to load comes only from battery The backup power to load comes from battery and PV energy ...

Страница 16: ...y second A88 PV Voltage High Beep every second A89 PV Current High Beep every second A91 PV Charger NTC Disconnect Beep every second E07 Output Voltage High Constant tone E09 Output Short Constant tone E14 Overload Fault Constant tone E18 Fan Fail Constant tone E13 Over Charge Constant tone E25 Output Voltage Unbalance Constant tone ...

Страница 17: ... Check the connection of AC input Backup time is short Overloading Disconnect non critical loads Battery voltage is too low Re charge battery for at least 8 hours Battery is bad Replace good quality batteries Alarm buzzer beeps continuously Inverter entered into fault mode Refer to the fault code to identify the fault and report to service representative for further assistance Solar are normal but...

Страница 18: ... charging AC CHARGE CURRENT 10 20 30 40A selectable FLOATING CHARGING VOLTAGE 27V 54V OVER CHARGING VOLTAGE 32V 64V MPPT SOLAR CHARGER Solar power to support load 1600W 3200W CHARGING CURRENT 60A Max NOMINAL BATTERY VOLTAGE 24V 48V MPPT operating voltage range 30 80V 60 150V Max PV Array Open Circuit Voltage 80V 150V MAX PV INPUT CURRENT 50A PWM SOLAR CHARGER Solar power to support load 1350W 2700...

Страница 19: ...ervice life please contact the local dealer for disposal instructions The product must not be disposed of with the household waste Disposal of the product at the end of its service life shall be done in accordance with applicable regulations for electronic waste ...

Страница 20: ...TERS INDONESIA Office PT PROLiNK INTIDATA NUSANTARA Walk In Jl Cideng Barat No 79 Jakarta Pusat 10150 Indonesia Email Support support id prolink2u com MALAYSIA Office FIDA SYSTEMS M SDN BHD Walk In 29 Jalan USJ 1 31 47600 Subang Jaya Selangor Darul Ehsan Malaysia Email Support support my prolink2u com SINGAPORE Office FIDA INTERNATIONAL S PTE LTD Walk In Block 16 Kallang Place 06 02 Kallang Basin ...

Отзывы: