background image

3

EVO128CYC

GENERAL INFORMATION

Shipments and claims

The goods are sold “ex works” and always travel at the risk and danger of the distributor. Eventual dam-

age will have to be claimed to the freight forwarder. Any claim for broken packs will have to be forwarded 

within 8 days from the reception of the goods.

Warranty and returns

The guarantee covers the fixture in compliance with existing regulations. You can find the full version of 

the “General Guarantee Conditions” on our web site www.musiclights.it. Please remember to register the 

piece of equipment soon after you purchase it, logging on www.musiclights.it. The product can be also 

registered filling in and sending the form available on your guarantee certificate. For all purposes, the va-

lidity of the guarantee is endorsed solely on presentation of the guarantee certificate. Music & Lights will 

verify the validity of the claim through examination of the defect in relation to proper use and the actual 

validity of the guarantee. Music & Lights will eventually provide replacement or repair of the products de-

clining, however, any obligation of compensation for direct or indirect damage resulting from faultiness.

Содержание EVO128CYC

Страница 1: ...EN IT Manuale Utente User Manual EVO128CYC STAGE THEATRE LED...

Страница 2: ...arziale per propri scopi commerciali vietata Al fine di migliorare la qualit dei prodotti la Music Lights S r l si riserva la facolt di modificare in qualunque momento e senza preavviso le specifiche...

Страница 3: ...mento in modalit automatica 3 5 Modalit Master Slave 3 6 Collegamento 3 7 Configurazione canali DMX 3 8 Modalit DMX 3 9 Impostazione dell indirizzo di start 3 10 Collegamenti della linea DMX 3 11 Cost...

Страница 4: ...urti in luoghi a temperatura superiore ai 45 C oppure a 20 C Evitare che nell unit penetrino liquidi infiammabili acqua o oggetti metallici Non smontare e non apportare modifiche all unit Tutti gli in...

Страница 5: ...elle Condizioni Generali di Garanzia Si prega dopo l acquisto di procedere alla registrazione del prodotto sul sito www musiclights it In alternativa il prodotto pu essere registrato compilando e invi...

Страница 6: ...ns 7200 Lux 1793 2m Diodi LED ad alta efficienza con colori pi vividi e minore assorbimento energetico delle lampade tradizionali Sistema di sintesi colore miscelazione RGBWA 16 milioni di colori per...

Страница 7: ...wercon XLR 3p 5p Cavi di alimentazione shuko e segnale xlr 3p inclusi Doppia staffa per il fissaggio in sospensione e per il posizionamento del proiettore da terra Alimentazione 100 240V 50 60Hz Condi...

Страница 8: ...IN connettore di potenza Neutrik per il collegamento ad una presa di rete 100 240V 50 60Hz tramite il cavo rete in dotazione 1 2 6 3 7 8 5 4 Vista posteriore 5 ALLOGGIAMENTO FUSIBILE in caso di rottur...

Страница 9: ...rotazione in senso orario fino all arresto L area di collocazione deve avere una stabilit sufficiente e supportare almeno 10 volte il peso dell unit Inoltre assicurarsi di rispettare tutte le avverte...

Страница 10: ...un interruttore 3 2 IMPOSTAZIONE BASE Il proiettore EVO128CYC dispone di un LED display e 4 pulsanti per accesso alle funzioni del pannello di controllo fig 5 Fig 5 MENU ENTER UP DOWN Per scorrere il...

Страница 11: ...WH 01 WH 11 R 000 255 G 000 255 B 000 255 W 000 255 A 000 255 CAL2 RGBw R 000 255 G 000 255 b 000 255 CALR OK 3 4 FUNZIONAMENTO IN MODALIT AUTOMATICA Se alla presa DMX non presente alcun segnale di c...

Страница 12: ...selezionare la configurazione dei canali DMX che si desidera TOUR TR16 ARC 1 AR1 d ARC 2 ARC3 AR3 D AR3 S HSV PIX1 PIX3 Le tabelle a pagina 15 indicano le modalit di funzionamento e i relativi valori...

Страница 13: ...n deve mai essere collegata alla terra dell impianto ci comporte rebbe malfunzionamenti delle unit e dei controller Per passaggi lunghi pu essere necessario l inserimento di un amplificatore DMX In ta...

Страница 14: ...esso indietro lungo il cavo provocando in certe condizioni e lunghezze la sua sovrapposizione al segnale originale e la sua cancellazione La terminazione deve essere effettuata sull ultima unit della...

Страница 15: ...210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 8 SPECIAL STROBE No strobe Strobe slow to fast No strobe Lightning strobe slow to fast No strobe Random strobe slow to fast...

Страница 16: ...11 AMBER 000 255 12 AMBER FINE 000 255 13 COLOR MACRO WHITE BALANCE No function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green Down Blue 100 Red Up Green 0 Blue1...

Страница 17: ...TROBE 0Hz 1Hz 2Hz 3Hz 4Hz 5Hz 6Hz 7Hz 8Hz 9Hz 10Hz 11Hz 12Hz 13Hz 14Hz 15Hz 16Hz 17Hz 18Hz 19Hz 20Hz 000 009 010 099 100 109 110 179 180 189 190 255 000 009 010 019 020 029 030 039 040 049 050 059 060...

Страница 18: ...000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 4 WHITE 0 100 000 255 ARC2 CH Function in ARC3 Value 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 4 WHITE 0 100 000 255 5 AMBER 0...

Страница 19: ...P DOWN 3 15 FUNZIONI SPECIALI Premere il tasto MENU e selezionare la voce SET per confermare premere il tasto ENTER possibile accedere alle seguenti funzioni NOTA Le impostazioni di fabbrica relative...

Страница 20: ...e o disabilitare la password Quando l unit impostata su ON bisogner immettere la password per accedere al menu impo stazioni STRB Il proiettore EVO128CYC dispone di due differenti impostazioni della s...

Страница 21: ...0 255 attraverso i tasto UP DOWN Quando la nuova impostazione attivata l unit di controllo DMX sceglier RGB 255 255 255 il colore bianco verr fatto dagli attuali valori RGB nella modalit CAL2 3 17 ATT...

Страница 22: ...e rimuovere il portafusibile dalla sua sede e il fusibile bruciato dal suo supporto sostituire il fusibile con uno identico per tipologia e valore 3 Inserire il portafusibile al suo posto e ricollegar...

Страница 23: ...TA ESPLOSA No ITEM 1 Lamp head 2 Base 3 Electrical source box 4 Reflective cup coverplate 5 Lens 6 10 degree grinding slice 7 Reflective cup 8 LED board 9 Lamp body heat dissipation profiles 10 End ca...

Страница 24: ...by any means for any commercial use In order to improve the quality of products Music Lights S r l reserves the right to modify the characteristics stated in this instruction manual at any time and w...

Страница 25: ...enu structure 3 4 Operation in automatic mode 3 5 Master Slave mode 3 6 Linking 3 7 DMX configuration 3 8 DMX mode 3 9 DMX addressing 3 10 Connection of the DMX line 3 11 Construction of the DMX termi...

Страница 26: ...mable liquids water or metal objects enter the fixture Do not dismantle or modify the fixture All work must always be carried out by qualified technical personnel Contact the nearest sales point for a...

Страница 27: ...e www musiclights it Please remember to register the piece of equipment soon after you purchase it logging on www musiclights it The product can be also registered filling in and sending the form avai...

Страница 28: ...f traditional lamps Colour synthesis RGBWA colour mixing 16 million colours for a limitless colour range and advanced control of white color temperature White color temperature preset 3200K 10000K Bea...

Страница 29: ...and for floor positioning Power supply 100 240V 50 60Hz Working conditions 20 45 Power output for daisy chain connection of more units up to 5 projectors at 230V Max output consumption 240W Weight 14...

Страница 30: ...4 N C 5 N C 3 DMX IN 3 pole XLR 1 ground 2 DMX 3 DMX 4 POWER IN Neutrik connector for connection to a socket 100 240V 50 60Hz via the supplied mains cable 1 2 6 3 7 8 5 4 5 MAIN FUSE HOLDER replace a...

Страница 31: ...tor is locked with a clockwise rotation until it stops When carrying out any installation always comply scrupulously with all the regulations particularly re garding safety currently in force in the c...

Страница 32: ...nction 3 FUNCTIONS AND SETTINGS 3 1 OPERATION Connect the supplied main cable to a socket 100 240 VAC 50 60 Hz Then the unit is ready for operation and can be operated via a DMX controller or it indep...

Страница 33: ...programmed and can be edited in EDIT mode In automatic mode the unit will be set as Master STAT RED R 000 255 GREN G 000 255 BLUE b 000 255 WHIT W 000 255 AMBE A 000 255 STRB S 0 20 AUTO AT 01 AT 10...

Страница 34: ...ENTER to confirm Select the desired DMX configuration TOUR TR16 ARC 1 AR1 d ARC 2 ARC3 AR3 D AR3 S HSV PIX1 PIX3 through the buttons UP DOWN The tables on page 13 indicate the operating mode and DMX v...

Страница 35: ...rts of the cable sleeve must never be connected to the system s earth as this would cause faulty fixture and controller operation Over long runs can be necessary to insert a DMX level matching amplifi...

Страница 36: ...ong the cable when they reach es the end of the line under certain conditions and with certain cable lengths this could cause them to cancel the original signals The termination is prepared by solderi...

Страница 37: ...171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 8 SPECIAL STROBE No strobe Strobe slow to fast No strobe Lightning strobe slow to fast No strobe Random...

Страница 38: ...11 AMBER 000 255 12 AMBER FINE 000 255 13 COLOR MACRO WHITE BALANCE No function Red 100 Green Up Blue 0 Red Down Green 100 Blue 0 Red 0 Green 100 Blue Up Red 0 Green Down Blue 100 Red Up Green 0 Blue1...

Страница 39: ...TROBE 0Hz 1Hz 2Hz 3Hz 4Hz 5Hz 6Hz 7Hz 8Hz 9Hz 10Hz 11Hz 12Hz 13Hz 14Hz 15Hz 16Hz 17Hz 18Hz 19Hz 20Hz 000 009 010 099 100 109 110 179 180 189 190 255 000 009 010 019 020 029 030 039 040 049 050 059 060...

Страница 40: ...000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 4 WHITE 0 100 000 255 ARC2 CH Function in ARC3 Value 1 RED 0 100 000 255 2 GREEN 0 100 000 255 3 BLUE 0 100 000 255 4 WHITE 0 100 000 255 5 AMBER 0...

Страница 41: ...select through the directional buttons the SETTINGS mode and press the but ton ENTER to confirm NOTE The factory access password is UP DOWN UP DOWN Press ENTER to confirm the access It is possible to...

Страница 42: ...two different strobe personality settings CLAS strobe or SPEC strobe The STRB settings are only valid in the DMX personalities TOUR AR2 S and TR16 3 16 CALIBRATION FUNCTION Press the button MENU to en...

Страница 43: ...activated the DMX controller choose RGB 255 255 255 the write color will be made by actual RGB values on the CAL2 3 17 ACTIVATE THE PASSWORD Enter the KEY mode to select whether the access password i...

Страница 44: ...etrate the unit and cause damage to it 4 2 FUSE REPLACEMENT 1 Remove the safety cap by a screwdriver 2 Replace the blown fuse with a fuse of the exact same type and rating 3 Install the safety cap and...

Страница 45: ...ODED VIEW No ITEM 1 Lamp head 2 Base 3 Electrical source box 4 Reflective cup coverplate 5 Lens 6 10 degree grinding slice 7 Reflective cup 8 LED board 9 Lamp body heat dissipation profiles 10 End cap...

Страница 46: ......

Страница 47: ...conseguenti sono a carico del possessore dell apparecchio A tutti gli effetti la validit della garanzia avallata unicamente dalla presentazione del certificato di garanzia The guarantee covers the un...

Страница 48: ...ate Data acquisto FORM TO BE FILLED IN AND MAILED CEDOLA DA COMPILARE E SPEDIRE FORM TO BE FILLED IN AND KEPT CEDOLA DA COMPILARE E CONSERVARE PROV ZIP CODE C A P MODEL MODELLO SERIAL N SERIE N Purcha...

Страница 49: ......

Страница 50: ......

Страница 51: ......

Страница 52: ...39 0771 721955 www musiclights it info musiclights it Music Lights S r l entertainment technologies ISO 9001 2008 Certified Company 2013 Music Lights S r l PROLIGHTS un brand di propriet della Music L...

Отзывы: