9
PHYRO1000D
2.8 DMX MODE
The PHYRO1000D is equipped with a DMX512 system. For connecting a DMX controller, 3-pin male-fe-
male XLR connections are provided at the back of each machine. The machines use one control channel
for adjusting the output volume.
2.9 DMX ADDRESSING
The PHYRO1000D has 1 DMX configuration with 1 channel. The table indicates the mode of operation and
its DMX values . As a DMX interface, the unit has contacts XLR 3-pin.
For to control the unit with a light control unit, set the DMX start address with the first free DMX channel. If,
for example, on the control unit is provided for the address 33 for controlling the function of the first DMX
channel, you must set on the PHYRO1000D the start address 33. The other functions of the panel will be
automatically assigned to successive addresses. Follows an example with the start address 33:
MODE
FUNCTION
DMX
Value
1 Ch
1
SMOKE OUTPUT
Off (no output)
Volume Output (1 - 100 % output)
000 - 001
002 - 255
Number of
DMX channels
Start address
(example)
DMX Address
occupied
Next possible start
address for unit No. 1
Next possible start
address for unit No. 2
Next possible start
address for unit No. 3
1
33
33
34
35
36
2.7 MENU STRUCTURE
MENU
1
Addr
ð
d1- d512
2
Ht
ð
H (160° - 200°)