Part Number 560361-020 Issue 1.0 November 2012.
5 of 13
The Liftwatch 5 Rated Capacity Indicator can be configured during installation to operate in one of two ways.
Automatic
If the auto-on link has been fitted to the display PCB, Liftwatch 5 will automatically power up when the machine ignition is switched on.
Manual
If the LCD display remains blank after the machine ignition is switched on, press the ON/OFF button once (circled in red below).
1
Power up
Once powered, Liftwatch 5 will perform an initialising process and system self test. If these processes are successful, normal operation
will commence. If a problem is detected, the system will fail to safe and all machine hydraulics will be disabled. The following page
describes possible failure states.