3
System test
If there is a suspected fault with the
Liftwatch 5 system, basic diagnostics are
available via the TEST button. The test
function can be accessed at any time
other than when in an overload condition.
Press TEST to access this feature. Press
TEST again to scroll through the available
displays. Press MODE at any time to exit
back to normal operation.
A brief description of each display is given
on the right.
Software version number (1.08). This number
should be quoted in any communication with Prolec
or their appointed agents.
Programmed boom length. This is the boom pivot
pin to arm pivot pin straight line distance in metres.
Equipment lengths can only be altered by Prolec or
their appointed agents.
Programmed arm length. This is the arm pivot pin to
lifting tool pin straight line distance in metres.
Equipment lengths can only be altered by Prolec or
their appointed agents.
When this display is shown the cab roof mounted
rotating beacon should operate (if fitted).
When this display is shown the external alarm
should operate.
When this display is shown the internal alarm should
operate.
When this display is shown the display amber LED
should operate.