background image

5

  SOLAR CONTROLLER SPECIFICATIONS

 

Electrical Parameters

 

1-1-1  Rated solar panel amps – SPM80K 

8  

Max.  

AMP

 

1-1-2  Rated solar panel amps – SPM120K 

12  

Max.  

AMP

 

1-2   Normal input Solar cell array voltage  

15–22  

 

VDC

 

1-3   Max. solar cell array voltage (output has no load)  

25  

Max.  

VDC

 

1-4   The controller lowest operating voltage (at solar or battery side) 

8V  

Min  

VDC

 

1-5   Standby current consumption at night  

5  

Max  

mA

 

1-6   Maximum voltage drop-Solar panel to battery  

0.25  

Max.  

VDC

 

2  

Charging characteristics

 

2-1   Minimum battery start charging voltage  

3  

Min  

VDC

 

2-2   Soft start charging voltage  

3-10  

+/-0.2  

VDC

 

2-3   Soft start charging current (50% PWM duty)  

 

 

 

2-4   Bulk charge voltage 10-14.0 +/-0.2 VDC

 

2-5   Absorption charging voltage at 25

o

 

• Gel type battery  

14.1  

+/-0.2  

VDC 

 

• AGM type battery (default setting)  

14.4  

+/-0.2  

VDC 

 

• WET type battery  

14.7  

+/-0.2  

VDC 

 

• Calcium type battery  

14.9  

+/-0.2  

VDC

 

2-6   Absorption transits to Equalizing or Float condition: 
 

• Charging current drops to : 

 

  – SPM80K 

0.5  

+/-0.1 

AMP 

 

  – SPM120K 

0.75 

+/-0.1 

AMP 

 

• or Absorption charging timer timed out  

4  

 

Hour

 

2-7   Equalization charging active 
 

• Only for WET or Calcium battery 

 

• Battery voltage discharged to less than  

10  

+/-0.2  

VDC 

 

• Automatic equalizing charging periodical  

28  

 

Day

 

2-8   Equalization charging voltage  

15.5  

+/-0.2  

VDC

 

2-9   Equalization charging timer timed out  

2  

 

Hour

 

2-10   Float charging voltage  

13.6  

+/-0.2  

VDC

 

2-11   Voltage control accuracy  

+/- 1%

 3  Protection

 

3-1   Against reverse polarity or short circuit at panel side

 

3-2   Against reverse polarity or short circuit at battery side

 

3-3   No reverse current from battery to solar at night

 

3-4   Over temperature protection during charging  

65  

 

o

C

 

3-5   Transient over voltage protection with TVS or varistor

 

4  

Electrical parts

 

4-1   Input output terminal  

 

M4 terminals

 

4-2   Temperature sensor port (Press and Release type)  

 

DA 250-350 2P

 

5  

Physical Parameters

 

5-1   Controller material  

  Plastic, Standard ABS

 

5-2   Power terminal maximum stranded wire size  

 #12 AWG stranded-3 mm

2

 

5-3   Mounting  

  Vertical wall mounting

 

5-4   IP grade  

 

IP22

 

5-5   Net weight Approx.  

 

250g

 

6  

Environmental characteristics

 

6-1   Operating temperature  

 

-25 ~ 50

o

C

 

6-2   Storage temperature  

 

-40 ~ 85

o

C

 

6-3   Operating Humidity range  

 100% no condensation

Содержание SPM80K

Страница 1: ...fied person if the unit requires repairing FEATURE OVERVIEW SOLAR PANEL Compact and Powerful Monocrystalline solar panels are manufactured from a solar cell that is cast from silicon These cells are m...

Страница 2: ...ill stop charging when the battery is full and will automatically start charging the battery as required This process will also reduce water loss and help prevent the battery from drying out Discharge...

Страница 3: ...f the solar charge controller this Dip switch is used for presetting your battery type Please refer to Figure 1 1 to make DIP switch setting for the proper battery chemical the factory default setting...

Страница 4: ...he loss of capacity Gel and AGM battery do not run Equalization charge Float Charge Level 5 Battery is fully charged and maintained at a safe level A fully charged battery has a voltage of more than 1...

Страница 5: ...or Absorption charging timer timed out 4 Hour 2 7 Equalization charging active Only for WET or Calcium battery Battery voltage discharged to less than 10 0 2 VDC Automatic equalizing charging periodi...

Страница 6: ...D Indication page 4 for further details of charging status STEP 3 Secure the solar panel to the ground Secure by pushing the legs into the ground For greater set up stability secure the panel to the g...

Страница 7: ...e my flat battery how long will it take A The SPM80K will charge a flat battery above 9V 250 900CCA Automotive with a charge time of 7 35Hrs The SPM120K will charge a flat battery above 9V 250 1200CCA...

Страница 8: ...purchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair...

Отзывы: