background image

1. 

To reduce the risk of electric shock, insure electricity has 

been turned off at the circuit breaker or fuse box before 

beginning.

2. 

All wiring must be in accordance with the National 

Electrical Code ANSI/NFPA 70-1999 and local electrical codes. 

Electrical installation should be performed by a qualified 

licensed electrician.

3. 

CAUTION: To reduce the risk of personal injury, use only 

the screws provided with the electrical box. 

4. 

The outlet box and support structure must be securely 

mounted and capable of reliably supporting 50 lbs. (22.68 

kg). Use only UL Listed outlet boxes marked “Acceptable 

for Fan Support of 50 lbs. ((22.68 kg) or less.”

5. 

CAUTION: The fan must be mounted with a minimum of 

7 feet clearance from the trailing edge of the blades to the 

floor.

6. 

Do not wait for the fan to stop before pressing the reverse 

button. The fan will not reverse direction if the fan is not 

moving.

7. 

Avoid placing objects in path of the blades.

8. 

To avoid personal injury or damage to the fan and other 

items, be cautious when working around or 

cleaning the fan.

9. 

Do not use water or detergents when cleaning the fan or fan 

blades. A dry dust cloth or lightly dampened cloth will be 

suitable for most cleaning. 

10. 

After making electrical connections, spliced conductors 

should be turned upward and pushed carefully up into 

electrical box. The wires should be spread apart with the 

grounded conductor and the equipment-grounding 

conductor on one side of the electrical box and ungrounded 

conductor on the other side of the electrical box.

11. 

Electrical diagrams are for reference only. Light kits that 

are not packed with the fan must be UL Listed and marked 

suitable for use with the model fan you are installing. 

Switches must be UL General Use Switches. Refer to the 

instructions packaged with the light kits and switches for 

proper assembly.

12. 

All set screws must be checked and retightened where 

necessary before installation.

13. 

WARNING: To reduce the risk of fire or electric shock, do 

not use this fan with any solid-state speed control device.

14. 

This fan should only be used with fan speed control part 

no. UC7067RYE, manufactured by Rhine Electronic Co., 

Ltd..

 1. Safety Rules

READ AND SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT TO OUTLET BOX MARKED “ACCEPTABLE FOR FAN 

SUPPORT OF 50 LBS. (22.68 KG) OR LESS”, AND USE SCREWS PRO-

VIDED WITH THE OUTLET BOX.

TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE 

BLADE BRACKETS (ALSO REFERRED TO AS (“FLANGES”) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN 

THE PATH OF THE BLADES.

TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED 

WITH AN ISOLATION CONTROL/SWITCH.

Содержание 785247221752

Страница 1: ...P2560 93089915_BB...

Страница 2: ...After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discretion and shall be purchaser s...

Страница 3: ...lling Your Fan Setting the Codes on Remote Control and Receiver Making the Electrical Connections Finishing the Fan Installation Operating Your Fan Care of Your Fan Troubleshooting Specifications Tabl...

Страница 4: ...ections spliced conductors should be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one...

Страница 5: ...ssembly 6 Switch Cup Adaptor 7 Switch Cup 8 Blade 5 9 Transmitter and Receiver 1 Mounting Bracket inside canopy 2 8 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy R...

Страница 6: ...l box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 20 If the canopy touches downrod remove the decorat...

Страница 7: ...s are on top Route the wires through the canopy and then through the ball downrod assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not rem...

Страница 8: ...he two screws provided with the outlet box If necessary use leveling washers not included between the mounting bracket and the outlet box Note that the flat side of the mounting bracket is toward the...

Страница 9: ...rtment in the back side of the transmitter B Slide code switches to your choice of up or down position factory setting is up C Replace the battery cover on the battery compartment of the transmitter 2...

Страница 10: ...Remote control model UC7067RYE 7 Making the Electrical Connections IF OTHER FAN OR SUPPLY WIRES ARE DIFFERENT PLEASE HAVE THIS UNIT INSTALLED BY A LICENSED ELECTRICIAN Follow the steps below to conne...

Страница 11: ...D CEILING MOUNTING 1 Align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two...

Страница 12: ...g in the switch cup with the molded adaptor plug of the fan motor assembly Figure 15 4 Attach the switch cup to the fan by aligning the three screws holes on switch cup with the screw holes on the swi...

Страница 13: ...ling effect as shown in Figure 18 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward air flow moves warm air off the ceiling...

Страница 14: ...TION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the swi...

Страница 15: ...uarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipme...

Страница 16: ......

Страница 17: ...P2560 93089915_B Manual de instalaci n del ventilador de techo B...

Страница 18: ...ra Pasados 30 d as el comprador original TIENE que contactar a Progress Lighting llamando al 864 678 1000 para reparaci n o reposici n seg n determine Progress Lighting a su entera discreci n y este s...

Страница 19: ...or C mo configurar los c digos del control remoto y el receptor C mo hacer las conexiones el ctricas C mo finalizar la instalaci n del ventilador C mo usar el ventilador Cuidado del ventilador Soluci...

Страница 20: ...s hacia arriba y empujarlos con cuidado hacia dentro de la caja de distribuci n Los cables deben estar separados con el cable y el conductor a tierra del equipo hacia uno de los lados de la caja el ct...

Страница 21: ...nterruptor 8 Aspas 5 9 Transmisor y receptor 1 Soporte de montaje dentro de la cubierta 2 Conjunto de tubo bajante bola de 8 20 3 cm pasadores de soporte y de cierre prefijados 3 Cubierta con aro de c...

Страница 22: ...stalar el ventilador en un techo inclinado El ngulo m ximo permitido es 20 Si la cubierta toca el tubo bajante retira la cubierta inferior decorativa y gira la cubierta 180 antes de fijarla a la placa...

Страница 23: ...Remove Loosen but Do Not Remove Figura 5 Figura 6 5 Afloja sin quitarlos los tornillos de fijaci n en el collar n de la parte superior de la carcasa de motor 6 Alinea los orificios en la parte inferi...

Страница 24: ...o Aseg rate de que la pesta a en el soporte de montaje est bien asentada dentro de la ranura de la bola de soporte Figura 9 Figura 8 Electrical Box Figura 9 Caja el ctrica aprobada por UL Soporte de m...

Страница 25: ...r del transmisor B Desliza los interruptores de c digo como desees hacia arriba o hacia abajo la configuraci n de f brica es hacia arriba C Coloca de nuevo la cubierta sobre el compartimento de las ba...

Страница 26: ...ptor usando una tuerca de cable Figura 11 5 Conecta el cable NEGRO del receptor al cable NEGRO de suministro de energ a positivo usando una tuerca de cable Figura 11 6 Conecta el cable BLANCO del rece...

Страница 27: ...s Touching Ceiling MONTAJE EST NDAR EN TECHO 1 Alinea las ranuras de cierre de la cubierta de techo con los dos tornillos de la placa de montaje Empuja hacia arriba para enganchar las ranuras y gira d...

Страница 28: ...do del conjunto motor ventilador Figura 15 4 Fija la caja del interruptor alineando los tres orificios de tornillos en ella con los orificios correspondientes en el adaptador Inserta los tres tornillo...

Страница 29: ...la Figura 18 Esto permite fijar tu aire acondicionado en configuraci n m s alta sin afectar tu comodidad Clima fr o Reversa Un flujo de aire hacia arriba desplaza el aire c lido lejos del techo como m...

Страница 30: ...lectricidad est apagada 3 Verifica las bater as en el transmisor Se enciende la luz LED roja Est s lo suficientemente cerca del ventilador El rango normal es de 10 20 pies 3 a 6 metros Coinciden las c...

Страница 31: ...a a comunicaciones radiales Sin embargo no hay garant a de que no ocurrir interferencia en una instalaci n particular Si este equipo causa interferencia perjudicial a la recepci n de radio o televisi...

Страница 32: ......

Отзывы: