background image

Pro-B4 1000 Air

4

www.profoto.com

SAfeTy PrecAUTionS!

Do not operate the equipment before studying the instruction manual and the accompanying safety.  
Make sure that Profoto Safety Instructions is always accompanied the equipment! Profoto products are 
intended for professional use! Do not place or use the equipment where it can be exposed to moisture, 
extreme electromagnetic fields or in areas with flammable gases or dust! Do not expose the equipment to 
dripping or splashing. Do not place any objects filled with liquids, such as vases, on or near the equipment. 
Do not expose the equipment to hasty temperature changes in humid conditions as this could lead to 
condensation water in the unit. Do not connect this equipment to flash equipment from other brands. 
Do not use flash heads without supplied protective glass covers or protective grids. Glass covers shall 
be changed if it has become visibly damaged to such an extent that their effectiveness is impaired, 
for example by cracks or deep scratches. Lamps shall be changed if they are damaged or thermally 
deformed. When placing a lamp into the holder ensure not to touch the bulb with bare hands. Equipment 
must only be serviced, modified or repaired by authorized and competent service personnel!  Warning - 
The terminals marked with the flash symbol are hazardous live.

WArninG – electrical Shock – High Voltage!

Mains powered generator shall always be connected to a mains socket outlet with a protective earthing 
connection!  Only use Profoto extension cables! Do not open or disassemble generator or lamp head! 
Equipment operates with high voltage. Generator capacitors are electrically charged for a considerable 
time after being turned off. Do not touch modeling lamp or flash tube when mounting umbrella metal 
shaft in its reflector hole. Disconnect lamp head cable between generator and lamp head when changing 
modeling lamp or flash tube! The mains plug or appliance coupler is used as disconnect device. The 
disconnect device shall remain readily operable. Batteries (battery pack or batteries installed) shall not 
be exposed to excessive heat such as sunshine, fire or the like.

caution – Burn Hazard – Hot Parts!

Do not touch hot parts with bare fingers! Modeling lamps, flash tubes and certain metal parts emit 
strong heat when used! Do not point modeling lamps or flash tubes too close to persons. All lamps may 
on rare occasions explode and throw out hot particles! Make sure that rated voltage for modeling lamp 
corresponds with technical data of user guide regarding power supply!

noTice – equipment overheating risk

Remove transport cap from lamp head before use! Do not obstruct ventilation by placing filters, diffusing 
materials, etc. over inlets and outlets of the equipment ventilation or directly over glass cover, modeling 
lamp or flash tube!

note about rf!

This equipment makes use of the radio spectrum and emits radio frequency energy. Proper care should 
be taken when the device is integrated in systems. Make sure that all specifications within this document 
are followed, especially those concerning operating temperature and supply voltage range. Make sure the 
device is operated according to local regulations. The frequency spectrum this device is using is shared 
with other users. Interference cannot be ruled out.

final Disposal

Equipment contains electrical and electronic components that could be harmful to the environment. 
Equipment may be returned to Profoto distributors free of charge for recycling according to WEEE. Follow 
local legal requirements for separate disposal of waste, for instance WEEE directive for electrical and 
electronic equipment on the European market, when product life has ended!

General safety instructions

711rent.com

Содержание Pro-B4 1000 Air

Страница 1: ...this user guide was downloaded from 711rent com the manual itself is copywrited by the manufacturer of the equipment all additional user information is copywrited by 711rent...

Страница 2: ...Pro B41000Air User s Guide 711rent com...

Страница 3: ...Pro B4 1000 Air 2 www profoto com 711rent com...

Страница 4: ...safety For this reason our equipment is widely used in rentalstudiosandrentalhousesworldwide fromParis London Milan NewYorkandTokyotoCapeTown Some photographers can tell just from seeing a picture if...

Страница 5: ...en mounting umbrella metal shaftinitsreflectorhole Disconnectlampheadcablebetweengeneratorandlampheadwhenchanging modeling lamp or flash tube The mains plug or appliance coupler is used as disconnect...

Страница 6: ...ange 9 Flash duration Mode control 10 Modeling light control 11 Synchronization Control through Profoto Air 11 Synchronization through cable or IR slave 12 Visible and audible signals 13 Flash before...

Страница 7: ...tton 6 DisplayButton 7 IndicatorDisplay 8 LampHeadOutletB 9 USBport 10 SyncControl 11 ModelControl 12 ReadyControl 13 ModeControl 14 DisplayA 15 DisplayB 16 ControlA 17 ControlB 18 ModelButtons 19 Rea...

Страница 8: ...eratorisready Changelightoutputandsettings 1 UsetheControlA 16 andControlB 17 tosetthelightoutputonoutletAandB 2 TheModeControl 13 shouldnormallybesettoNORMAL Forshortflashduration set the control to...

Страница 9: ...blebyturningthebayonetconnectorplug 2 The red LED on the Pro B4 Battery Charger indicates that charging is in progress ThegreenLEDindicatesthatchargingiscompleted The battery has no memory effect and...

Страница 10: ...stopincrementsandcounter clockwisetodecrease The Displays A 14 and B 15 show the selected energy or OFF when the lamp head is turnedoff The lamp heads can be turned off by pressing and holding the res...

Страница 11: ...urationcanbedisplayedintheDisplaysA 14 andB 15 bypushingtheDisplay Button 6 Whenflashdurationisselected 1 sisshownintheIndicatorDisplay 7 The flash duration varies with the energy level setting see se...

Страница 12: ...theonewithhighestenergylevel Themodellinglightonone lamp head will get maximum intensity and the other will correspond proportionally A consequenceisthatthemodelinglightmaychangeonalampheadwhichisnot...

Страница 13: ...evenly spreadovertheentirefrequencyband tooptimizereliablefunctionality Thelargenumberofradiochannelsmakesit possibletoselectachannelthatisnotinterferedbyotherphotographersusingProfotoAir orbyWLANand...

Страница 14: ...nd fully to the set value The incorrect exposure of the image may be so small that it makes no significant difference and the image may stillbeusableifthecatchofthemomentwasperfect Testfunction TheTes...

Страница 15: ...nergylevelfor bothchannelschange atthesametime TheModeControl 13 issettoMASTER SettheModeControl 13 toNORMAL Themodelinglightsare notlit Themodelinglights maynotbeturnedon Thelampsocketmay bedeactivat...

Страница 16: ...ormal Rechargethebattery PresstheOn Off Button 5 toturnonthe generator Recyclingissloworhas stoppedcompletely Thegeneratoror batteryisoverheated Thebattery temperatureistoolow Ensurebetterventilation...

Страница 17: ...800 Koverentireenergyrange 150 Kflash to flash Energystability Normalmode 1 100f stopflash to flash Freezemode 1 20f stopflashtoflash Numberoflampheadsockets 2 Modelinglight Maximum500Wintotal contin...

Страница 18: ...oStudioviaProfotoAir Size 25 5x18 5x25cm 10x7 3x9 8in Weight 9 8kg 22lbs includingbattery Flashdurationondifferentenergysettings InNORMALmode InFREEZEmode Flashduration t0 5 Energy Lightoutput Flashdu...

Страница 19: ...s 8 0 1 5500s 7 9 1 5500s 7 8 1 5500s 7 7 1 5500s 7 6 1 5500s 7 5 1 5500s 7 4 1 5000s 7 3 1 5000s 7 2 1 5000s 7 1 1 5000s 7 0 1 5000s 6 9 1 5000s 6 8 1 4500s 6 7 1 4500s 6 6 1 4500s 6 5 1 4500s 6 4 1...

Страница 20: ...1 25000s 4 7 1 3500s 4 6 1 25000s 4 6 1 3500s 4 5 1 25000s 4 5 1 3000s 4 4 1 23000s 4 4 1 3000s 4 3 1 23000s 4 3 1 3000s 4 2 1 23000s 4 2 1 3000s 4 1 1 21000s 4 1 1 2500s 4 1 21000s 4 1 2500s 3 9 1 2...

Страница 21: ...2 5 1 2000s 2 4 1 16500s 2 4 1 2000s 2 3 1 16500s 2 3 1 2000s 2 2 1 16000s 2 2 1 2000s 2 1 1 16000s 2 1 1 2000s 2 0 1 15000s 2 1 15000s 1 9 1 15000s 1 8 1 15000s 1 7 1 15000s 1 6 1 15000s 1 5 1 15000s...

Страница 22: ...rmationonaccessories Warranty AllProfotogeneratorsandheadsareindividuallytestedbeforetheyleavethecompanyand guaranteedforaperiodoftwoyears localdeviationsmayapply withtheexceptionofflash tubes glass c...

Страница 23: ...fications not expressly approved by the party responsible for compliance could void the user s authoritytooperatetheequipment Ce dispositif est conforme aux normes RSS 210 d Industrie Canada L utilisa...

Страница 24: ...assificationofspecifiedradioequipment Article2 Clause1 Item19 2 4GHzWideBandLowPowerDataCommunication 38 24 1 Thisistocertifythattheabove mentionedcertificationbytypehasbeengrantedin accordancewiththe...

Страница 25: ...ProfotoAB SWEDEN Phone 4684475300 info profoto com www profoto com 344034 A1 Printed in Sweden Technical data and product information are subject to change without notice 711rent com...

Отзывы: