Visible and audible signals

The Ready Lamp [19] is illuminated when the generator is fully charged and ready to flash. 
When the energy level is changed, the Ready Lamp [19] and the modeling lights turn off, 
indicating that dumping or charging of energy is in progress.

The Ready Control [12] is used to select ready signaling:

•  BEEP: A short audible signal indicates that the recycling of the generator is completed. 
•  BUZZ: An audible signal with several “beeps” indicates that recycling is in progress.
•  OFF:  Ready signaling deactivated. 

If a flash is triggered before recycling or auto dumping, there will be a long “beep”. See also 

section 

Flash before ready function

Before the generator automatically turns of (after 30 minutes of inactivity), there will a 

number of short “beeps”.

flash before ready function

The Flash before ready function makes it possible to flash before the recycling or auto 
dumping of the generator is fully completed. When a flash is released before the generator 

is 100% ready, there will be a long “beep”, indicating an incorrectly exposed image. 

Naturally the flash light may not correspond fully to the set value. The incorrect exposure 
of the image may be so small that it makes no significant difference and the image may 
still be usable if the catch of the moment was perfect.

Test function

The Test Button [19] is used to test that all light settings are correct and that the functionality 
is as expected. When the Test Button [19] is pressed, the generator will flash and the Ready 
Lamp [19] will be turned off. When the recycling of the generator is completed, the Ready 
Lamp [19] will be turned on again.

USB port

The USB port [9] is intended for firmware upgrade of the generator. The port cannot be used 
to connect the Pro-B4 to your PC or Mac via an USB cable.

Safety and protection functions

The Pro-B4 generator is equipped with integrated fans and the casing is made of cast aluminum 
to effectively dissipate heat. The fans will automatically start running when the generator is 
operating at higher energy levels or when the generator is used in hot environments. If there is a 
risk for overheating, the recycling of the generator will slow down or stop. If the generator or the 

battery is overheated “ot” will be indicated I the displays. After a while, when the temperature 

has decreased sufficiently, the generator will start working as normal again.

The generator automatically shuts down if the battery level is too low, to protect it from 
deep battery discharge.

711rent.com

Содержание Pro-B4 1000 Air

Страница 1: ...this user guide was downloaded from 711rent com the manual itself is copywrited by the manufacturer of the equipment all additional user information is copywrited by 711rent...

Страница 2: ...Pro B41000Air User s Guide 711rent com...

Страница 3: ...Pro B4 1000 Air 2 www profoto com 711rent com...

Страница 4: ...safety For this reason our equipment is widely used in rentalstudiosandrentalhousesworldwide fromParis London Milan NewYorkandTokyotoCapeTown Some photographers can tell just from seeing a picture if...

Страница 5: ...en mounting umbrella metal shaftinitsreflectorhole Disconnectlampheadcablebetweengeneratorandlampheadwhenchanging modeling lamp or flash tube The mains plug or appliance coupler is used as disconnect...

Страница 6: ...ange 9 Flash duration Mode control 10 Modeling light control 11 Synchronization Control through Profoto Air 11 Synchronization through cable or IR slave 12 Visible and audible signals 13 Flash before...

Страница 7: ...tton 6 DisplayButton 7 IndicatorDisplay 8 LampHeadOutletB 9 USBport 10 SyncControl 11 ModelControl 12 ReadyControl 13 ModeControl 14 DisplayA 15 DisplayB 16 ControlA 17 ControlB 18 ModelButtons 19 Rea...

Страница 8: ...eratorisready Changelightoutputandsettings 1 UsetheControlA 16 andControlB 17 tosetthelightoutputonoutletAandB 2 TheModeControl 13 shouldnormallybesettoNORMAL Forshortflashduration set the control to...

Страница 9: ...blebyturningthebayonetconnectorplug 2 The red LED on the Pro B4 Battery Charger indicates that charging is in progress ThegreenLEDindicatesthatchargingiscompleted The battery has no memory effect and...

Страница 10: ...stopincrementsandcounter clockwisetodecrease The Displays A 14 and B 15 show the selected energy or OFF when the lamp head is turnedoff The lamp heads can be turned off by pressing and holding the res...

Страница 11: ...urationcanbedisplayedintheDisplaysA 14 andB 15 bypushingtheDisplay Button 6 Whenflashdurationisselected 1 sisshownintheIndicatorDisplay 7 The flash duration varies with the energy level setting see se...

Страница 12: ...theonewithhighestenergylevel Themodellinglightonone lamp head will get maximum intensity and the other will correspond proportionally A consequenceisthatthemodelinglightmaychangeonalampheadwhichisnot...

Страница 13: ...evenly spreadovertheentirefrequencyband tooptimizereliablefunctionality Thelargenumberofradiochannelsmakesit possibletoselectachannelthatisnotinterferedbyotherphotographersusingProfotoAir orbyWLANand...

Страница 14: ...nd fully to the set value The incorrect exposure of the image may be so small that it makes no significant difference and the image may stillbeusableifthecatchofthemomentwasperfect Testfunction TheTes...

Страница 15: ...nergylevelfor bothchannelschange atthesametime TheModeControl 13 issettoMASTER SettheModeControl 13 toNORMAL Themodelinglightsare notlit Themodelinglights maynotbeturnedon Thelampsocketmay bedeactivat...

Страница 16: ...ormal Rechargethebattery PresstheOn Off Button 5 toturnonthe generator Recyclingissloworhas stoppedcompletely Thegeneratoror batteryisoverheated Thebattery temperatureistoolow Ensurebetterventilation...

Страница 17: ...800 Koverentireenergyrange 150 Kflash to flash Energystability Normalmode 1 100f stopflash to flash Freezemode 1 20f stopflashtoflash Numberoflampheadsockets 2 Modelinglight Maximum500Wintotal contin...

Страница 18: ...oStudioviaProfotoAir Size 25 5x18 5x25cm 10x7 3x9 8in Weight 9 8kg 22lbs includingbattery Flashdurationondifferentenergysettings InNORMALmode InFREEZEmode Flashduration t0 5 Energy Lightoutput Flashdu...

Страница 19: ...s 8 0 1 5500s 7 9 1 5500s 7 8 1 5500s 7 7 1 5500s 7 6 1 5500s 7 5 1 5500s 7 4 1 5000s 7 3 1 5000s 7 2 1 5000s 7 1 1 5000s 7 0 1 5000s 6 9 1 5000s 6 8 1 4500s 6 7 1 4500s 6 6 1 4500s 6 5 1 4500s 6 4 1...

Страница 20: ...1 25000s 4 7 1 3500s 4 6 1 25000s 4 6 1 3500s 4 5 1 25000s 4 5 1 3000s 4 4 1 23000s 4 4 1 3000s 4 3 1 23000s 4 3 1 3000s 4 2 1 23000s 4 2 1 3000s 4 1 1 21000s 4 1 1 2500s 4 1 21000s 4 1 2500s 3 9 1 2...

Страница 21: ...2 5 1 2000s 2 4 1 16500s 2 4 1 2000s 2 3 1 16500s 2 3 1 2000s 2 2 1 16000s 2 2 1 2000s 2 1 1 16000s 2 1 1 2000s 2 0 1 15000s 2 1 15000s 1 9 1 15000s 1 8 1 15000s 1 7 1 15000s 1 6 1 15000s 1 5 1 15000s...

Страница 22: ...rmationonaccessories Warranty AllProfotogeneratorsandheadsareindividuallytestedbeforetheyleavethecompanyand guaranteedforaperiodoftwoyears localdeviationsmayapply withtheexceptionofflash tubes glass c...

Страница 23: ...fications not expressly approved by the party responsible for compliance could void the user s authoritytooperatetheequipment Ce dispositif est conforme aux normes RSS 210 d Industrie Canada L utilisa...

Страница 24: ...assificationofspecifiedradioequipment Article2 Clause1 Item19 2 4GHzWideBandLowPowerDataCommunication 38 24 1 Thisistocertifythattheabove mentionedcertificationbytypehasbeengrantedin accordancewiththe...

Страница 25: ...ProfotoAB SWEDEN Phone 4684475300 info profoto com www profoto com 344034 A1 Printed in Sweden Technical data and product information are subject to change without notice 711rent com...

Отзывы: