QUICK-MANUAL for multiGuard Technic RF 

 

 
 

 

www.profort.com  

p. 

1

 

Mounting 

1.

 

Prepare a SIM card so that the PIN code is 1234 or deactivated. Mount the card in the unit. The unit 
now has 1234 as password or runs without a password. The card is turned the way shown below.  

2.

 

Connect inputs, outputs and power cable (12-24 VAC/DC).  

3.

 

Connect power. The unit first gives one short beep and then a red diode is lit. After approximately 20 
sec. the diode flashes every 2 sec. and the unit is ready. 

4.

 

Connect a rechargeable 3,6 V Li-ion battery. 

 

The multiGuard unit interior 

 
  

DIP-switch for analogue input 2 (AN 2) 

 

 

1 ON: 

 0-10 VDC 

2 ON: 

 0/4-20 mA 

3 ON: 

 PT-100 

4 ON: 

 Profort, PTC- probe 

All OFF:  

 digital input 

Voltage on in- and outputs 

  

Output:  

AC max 230 VAC, 6A 

 

DC max 30 VDC, 6A 

Inputs, digital: 

max 12 VDC 

 

max power 2 mA 

Input, analogue 2:  max 0-10 VDC 

 

Press only voltage when DIP- 

 

switch 1 is on and 2-4 are off 

Input, analogue 1: Profort, PTC probe 

Содержание multiGuard Technic RF

Страница 1: ...ne short beep and then a red diode is lit After approximately 20 sec the diode flashes every 2 sec and the unit is ready 4 Connect a rechargeable 3 6 V Li ion battery The multiGuard unit interior DIP...

Страница 2: ...choose a unique USERNAME You need the username to log on www profort com and or to activate the Internet access of the unit 3 Send following text messages to the unit Notice 1234 password Space counts...

Страница 3: ...on input x by opening closing x 0 1 or 2 1234 Lx TEXT TEXT on input x by opening closing x 0 1 or 2 Delete 1234 Ax Deletes TEXT for input x by opening closing x 0 1 or 2 1234 Lx Deletes TEXT for input...

Страница 4: ...rm on an input Outputs follow condition on inputs 1234 GA Indicates that the output follows the corresponding input if text is created Notice input signal has higher priority than command S0 S zero an...

Страница 5: ...ower in percent 25 is lowest acceptable value yy battery status 1234 V1 R Downloads measurements on the analogue input Connection to the Internet 1234 EH USERNAME GPRS traffic starts 1234 EH GPRS traf...

Страница 6: ...s in the same macro are divided by semicolon without space Example 1234 SHORT PULSE S0 B0 Play macro TEMP Plays the macro with the name TEMP Delete macro no 1 1234 M1 Deletes macro 1 M0 M9 For further...

Страница 7: ...0V DC 0 4 20mA PT 100 Profort temperature sensor Profort no 007995 Pulse and minute counter Max 10Hz Max one mio pulse or minutes Dimension Design box black 130x85x24 mm weight 125 g Temperature 20 C...

Страница 8: ...12 24 V power supply 9 V rechargeable back up battery acquisition Modbus interface IP 65 box Touch display for set up and programming multiGuard Remote IO 1 relay output 2 senders of infrared codes f...

Отзывы: