COMMISSIONING
Page 8
ELECTRICAL
1.
Connect the appliances power cord to the transformers
output.
2.
Plug the transformer into an electrical outlet.
PRESSURIZING
1.
Put the bypass system in 'bypass' position.
2.
Make sure the electronic controller of the appliance is in
service mode.
3.
Open the mains water supply.
4.
Open a cold treated water faucet nearby the appliance
and let the water run for a few minutes until all air is
purged and all foreign material that may have resulted
from the installation is washed out; close the tap.
5.
Gently pressurize the appliance, by putting it into service:
close the 'BYPASS' valve;
open the 'OUT' valve;
slowly open the 'IN' valve.
6.
After 2-3 minutes, open a cold treated water faucet
nearby the appliance and let the water run for a few
minutes until all air is purged from the installation and the
filter media is rinsed (it is normal for the rinse water to
show some discoloration!); close the tap.
7.
Check the appliance and all hydraulic connections for
leaks.
ELECTRONIC CONTROL PANEL
1.
Program the electronic controller.
INITIATE A REGENERATION
1.
Manually initiate a regeneration, by pressing the scroll
button; the display will show:
2.
Leave the appliance in this position; the count-down
timer will count down to 0 sec and start a regeneration;
to save time you may skip, or terminate prematurely, the
second cycle of the regeneration by pressing the scroll
button once, as soon as the display indicates that the
system is in the second regeneration position.
Regen in 10 sec
Содержание PF-BTA
Страница 15: ...Page 15...
Страница 21: ...E Page 21...
Страница 22: ...EXPLODED VIEW PF MMX SYSTEM Page 22...
Страница 24: ...EXPLODED VIEW PF MMX TIMER ASSEMBLY Page 24...
Страница 26: ...EXPLODED VIEW PF MMX VALVE BODY Page 26...
Страница 31: ...Page 31...
Страница 32: ...erie water treatment a division of Aquion Inc www eriewatertreatment com...