![ProfiTap C1P-1G Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/profitap/c1p-1g/c1p-1g_product-manual_1611200006.webp)
3
1.6 Power Failure
When the TAP becomes unpowered, it activates its bypass circuits, connecting network
ports A and B together. Monitor ports are disabled when the TAP is unpowered.
1.6.1 Fast Failover (C1P-1G, C1R-1G, C1R-1G-48V)
When a power transition event occurs, the network devices renegotiate the link. This
operation can take up to 5 seconds depending on network configuration and can cause
a network topology reconfiguration. The Fast Failover feature helps to reduce this time by
trying to keep the link up without renegotiation during the power change event.
With Fast Failover, the network path unavailability lasts between 30 and 300 ms.
1.6.2 Battery Failover (C1R-1G-BAT)
When a power transition event occurs, the battery enables the network link to stay up
without interruption, preventing any risk of topology reconfiguration, and avoiding any loss
of packets.
1.7 Battery (C1R-1G-BAT)
BATT LED states:
Steady Green: Battery Charging (1.7.1)
Steady Orange: Battery Checking / Charging (1.7.1)
Blink Green: Battery Discharging (1.7.2)
Blink Orange: Battery Discharging (1.7.2)
or Maintenance (1.7.3)
Steady Red: Battery life suboptimal. Replace the battery for optimal performance. (1.7.4.2)
Off: No Battery (1.7.4.1)