EN
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space hea-
ters only (select one)
Nominal heat
output
P
nom
2.0
kW
Manual heat charge control, with integrated
thermostat
no
Minimum heat
output (indicative)
P
min
1.0
kW
Manual heat charge control with room and/or
outdoor temperature feedback
no
Maximum conti-
nuous heat output
P
max,c
2.0
kW
Electronic heat charge control with room and/or
outdoor temperature feedback
no
Auxiliary electricity consumption
Fan assisted heat output
no
At nominal heat
output
el
max
N.A.
kW
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
N.A.
kW
Single stage heat output and no room tempera-
ture control
no
In standby mode
el
SB
0
kW
Two or more manual stages, no room temperatu-
re control
no
With mechanic thermostat room temperature
control
yes
With electronic room temperature control
no
Electronic room temperature control plus day
timer
no
Electronic room temperature control plus week
timer
no
Other control options (multiple selections possible)
Room temperature control, with presence
detection
no
Room temperature control, with open window
detection
no
With distance control option
no
With adaptive start control
no
With working time limitation
no
With black bulb sensor
no
Contact details
ELTRA NV
Pachtgoedstraat 2 - Ind.zone C TTS, 9140 TEMSE
INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS