English 5

4 English

7. Security tipS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

  Pumping inflammable, as well as all other aggressive 

liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

  Never pull the pump on the electrical cable or pressure 

hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size 

 

l

  During longer unused times, clean the pump, wash it out 

with clear water, dry and store it at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

  The pump is to be secured through a RCD circuit  breaker 

with a release current of 30 mA.

 

l

  The electrical connections are always to be carried out by an 

authorised professional.

 

l

  The pump may be used by children aged 8 years and 

above as well as persons with reduced physical, sensory 

or mental abilities or those who lack skills, experience and 

knowledge only if they are supervised. These aforementi-

oned persons should only use the appliance while adhering 

to safe instructions and resulting dangers.

 

l

  Cleaning and maintenance must not be carried out by child-

ren without supervision.

 

l

  The pump must not be used or operated under any circum-

stances when there are people in the same water.

 

l

  Under certain cirumstances, it is possible that that contami-

nation of water is caused by leakage.

the manufacturer explainS:

l

  To take over no responsibility in the case of accidents or damages 

on the basis of carelessness or disregard to the instructions in this 

book.

l

  To reject every responsibility for the damages which originate 

from the improper use of the pump.

8. recogniSing and repairing of miStakeS

problem

possible cause

Solution

Pump runs, no water is being 

pumped

Air in the system (cannot escape)

Air in the system must be let out

Impeller wheel is blocked

Impeller wheel must be cleaned

Pump does not start or switches 

itself off

Engine guard has switched the pump off 

Pump needs to be cooled

No electricity

Check electrical connections

Pump runs, Pump capacity slows 

down or  stops

Pump is inserted to deep

Insert pump not so deep

Hose connections systems have a leak

Check hose connection systems

Impeller wheel is worn down

Change impeller wheel

Filter has become dirty

Clean filter

When you turn on the pump the

FI switch triggered

Pump leaks

examine pump moisture damage

Condensation in the electrical connection / 

terminal box

Disconnect from mains plug / 

Information to supplier

9. noteS on product liability 

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no 

changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original 

spare parts and accessories were used.

10. noteS on diSpoSal

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to 

be disposed in your household garbage. We are registered at the German registration department EAR 

under the 

Weee-no. de25523173.

 This symbol means, that you’re not allowed to treat this product as  

a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. 

This is the best way to save and protect our earth.

thank you for your Support! 

11. eu declaration of conformity

The products listed overleaf accordance with the marketed in accordance with the relevant provisions listed below, the 

relevant EU directives and harmonized with EU standards for safety. This declaration is valid insofar on the product, 

no changes are made.
Authorized person to keep the technical documents:

1A-Profi-Handels GmbH · Unterriethstraße 37 · D-65187 Wiesbaden

low Voltage directive (2006/95/ec)

ec electromagnetic compatibility directive (2004/108/ec)

EN ISO12100:2010, EN 60204-1:206+A1:2009, EN809:1998+A1:2009

EN60335-1:2002+A1:2004+A2:2006+A12:2006+A13:2008+A14:2010+A15:2011

EN60335-2-41:2003+A1:2004+2:2010, EN55014-1:2006+1:2009, EN61000-3-3:2008

EN55014-2:1997+A1:2001+A2:2008, EN61000-3-2:2006-A1:2009+A2:2009
Wiesbaden, 1st October 2017

ppa. Peter Neumüller

 

Содержание BRUNNEN-STAR 750-8

Страница 1: ...cts can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de operating inStructionS bedienungSanleitung de 3 Tiefbrunnenpumpe SCREW STAR 1100 7 BP01131 4 Tiefbrunnenpumpe SCREW STAR 1100 7 BP01133 3 Tiefbrunnenpumpe BRUNNEN STAR 750 8 Impellerpumpe BP01132 ...

Страница 2: ...e that a 30mA RCD circuit breaker secured outlet is installated Then install the pump cable in the thermal protective switch box Lead the cable through the screw connection opening from the outside into the box The wires are marked with numbers Secure the cables in the electrical clamp strip according to the numberings See fig right Tighten the screw connection of the cable realisation and screw t...

Страница 3: ...p off Pump needs to be cooled No electricity Check electrical connections Pump runs Pump capacity slows down or stops Pump is inserted to deep Insert pump not so deep Hose connections systems have a leak Check hose connection systems Impeller wheel is worn down Change impeller wheel Filter has become dirty Clean filter When you turn on the pump the FI switch triggered Pump leaks examine pump moist...

Страница 4: ...er Schutz schalter Box Führen Sie das Kabel durch die dafür vorgesehene Verschraubung von außen in die Box Die Drähte sind mit Zahlen markiert Schließen Sie diese an die elektr Klemmleiste entsprechend der Nummerierung an Siehe Abb rechts Ziehen Sie die Verschraubung der Kabeldurchführung fest und verschrauben Sie den Deckel Achten Sie dabei auf den ordentlichen Sitz der Deckelgummidichtung Flexib...

Страница 5: ...Person zur Aufbewahrung der technischen Dokumente 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Richtlinie Niederspannung 2006 95 EG Richtlinie Elektromagnetische Verträglichkeit 2004 108 EG Folgende harmonisierte Normen EN ISO12100 2010 EN 60204 1 206 A1 2009 EN809 1998 A1 2009 EN60335 1 2002 A1 2004 A2 2006 A12 2006 A13 2008 A14 2010 A15 2011 EN60335 2 41 2003 A1 2004 2 2010 EN5501...

Страница 6: ...artikelgröße 0 2 mm 0 2 mm 0 2 mm Protection grade Schutzklasse IPX8 IPX8 IPX8 Electrical tension Spannung 230V 50 Hz 230V 50 Hz 230V 50 Hz Connection pressure side IT Anschluss Druckseite IG 1 IG 1 IG 1 IG Diameter Durchmesser 32 mm 98 5 mm 78 mm Height Höhe tba folgt tba folgt 53 cm Weight Gewicht 13 kg 16 kg 12 kg Cable length Kabellänge 15 m 15 m 15 m Thermal protector switch box only applicab...

Отзывы: