background image

contents

  1.  Introduction  ........................................................................................................................................................... 2

  2.  In general  .............................................................................................................................................................. 2

  3.  Ranges of application  ........................................................................................................................................... 2

  4.  Operation  .............................................................................................................................................................. 2

  5.  Servicing  ............................................................................................................................................................... 3

  6.  Guarantee regulations  .......................................................................................................................................... 3

  7.  Security tips ........................................................................................................................................................... 4

  8.  Recognising and repairing of mistakes  .................................................................................................................  5

  9.  Notes on Product Liability  .....................................................................................................................................  5

10.  Notes on Disposal  ................................................................................................................................................. 5

11.  EU Declaration of Conformity  ...............................................................................................................................  5

12.  Technical Data  .................................................................................................................................................... 10

English 3

2 English

1. introduction

We would like to congratulate you  on the purchase of our pump. We appreciate your trust. That‘s why funtional 

security and operational safety stands by us on fi rst place.

 

 to prevent damage to persons or property, you should read this user manual carefully. please 

observe all safety precautions and instructions for proper use of the pump. failure to follow the 

instructions and safety precautions can result in injury or property damage.

   please keep this manual with the instructions and safety instructions carefully in order to at any 

time you can restore them.

2. in general

The pumps are developed according to the newest stand of technology, manufactured with much care and go under 

strict intensive controls. These pumps were optimised by us in particular for the special demands in dirty water 

areras. Make sure after unpacking the pump that the data given on the type label match with the included operating 

instructions. In case of doubt the pump is not to be used.

Transport damages are immediately to be reported to the package distributor and to us in written form.

3. rangeS of application

These pumps are made for pumping clear water (free of mud and sand and aggressive chemical substances (see 

technical data). The water may have to be pre-fi ltered to 0.2 mm particle size

The pumps are made for the following ranges of application:

l

 domestic water use from wells with diameter from 3-inch diameter

l

 circulation of large accumulations of water from containers

l

 Other plain water pumping

important!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in 

case of improper use. They are not suitable for pumping fl ammable liquids or for use in places where there is a risk 

of explosion. The pumps are designed for home use in the house and garden. 

These pumps are designed for continuous use provided (max. 20 interruptions per hour). Never run more than 

2-3 minutes against a closed valve pump. (Install dry running protection) pump adequately secured against dry running.

The pump must not be used in swimming pools.

Not suitable for use with solar photovoltaic panels.

Please read the user manual before using

the pump

Warning sign

Pull power plug

Warning of electrical voltage

Safety inStruction and WarningS

Mount the THERMAL PROTECTOR SWITCH BOX 

(only included With the brunnen-Star 750-4)

 at a place 

suitable according to the protective class. Assure that a 30mA RCD circuit breaker secured outlet is installated. Then install  the 

pump cable in the thermal protective switch box. Lead the cable through the screw connection opening from the outside into the 

box. The wires are marked with numbers. 

Secure the cables in the electrical clamp strip according to the numberings (See fi g. right). Tighten the screw connection of the 

cable realisation and screw the lid together. Pay attention that the rubber sealing ring sits tight.

   

Flexible hose

Panzerschlauch

Towing rope

Zugseil

Thermal protector 

switch box

Motor Schutz-

schalter-Box

6. guarantee regulationS

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement 

or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the 

warranty on our service platform http://www.profi -pumpe.de/service.php. We will inform you how to proceed with 

case-related. Returns please suffi cient postage. Unfortunately not prepaid returns can not be accepted because they 

are fi ltered out before delivery. Our service we provide in Germany.

The warranty does not cover:

l

 Improper installation (self-installation, unauthorized persons)

l

 Material wear (sealing rings, impeller wheels, impeller chambers)

l

 Unjustifi ed interventions or changes in the pump

l

 Damages by selffault

l

 Improper servicing and improper use

l

 DRY RUNNIG (Also partially!) of the pump

moreover, we give no damage compensation for secondary damages!

4. operation

 

The installation must be performed by a qualifi ed professional.

 

 Please, check each time before using, the electrical connections and the cables are not damaged. Check 

before the installation whether the electrical connections are earthed according to the statutory regulations 

and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA.

Also, it is NOT recommended to perform, for example, a cable extension. It is not certain whether this modi-

fi cation is technically correct, so this warranty is void. It must be ensured that the pump is suffi ciently cooled 

during prolonged operation.

5. SerVicing

 

 Under normal pumping conditions the pump requires no servicing. From an operating period (with clear 

water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, 

sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in the chamber 

should also be changed, if necessary (only with oil-dipped engine types!). Please, only fi ll it up to 80% and 

check the sealing rings always for density.

 

With abrasive materials like sand the servicing duration can become shorter.

 

The following controls should be carried out regularly:

 

l

 Intactness of the electric cable

 

l

 That the connection hoses are not bent or broken

 

l

 Cleanness of the pump medium 

 

Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.

Содержание BRUNNEN-STAR 750-8

Страница 1: ...cts can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de operating inStructionS bedienungSanleitung de 3 Tiefbrunnenpumpe SCREW STAR 1100 7 BP01131 4 Tiefbrunnenpumpe SCREW STAR 1100 7 BP01133 3 Tiefbrunnenpumpe BRUNNEN STAR 750 8 Impellerpumpe BP01132 ...

Страница 2: ...e that a 30mA RCD circuit breaker secured outlet is installated Then install the pump cable in the thermal protective switch box Lead the cable through the screw connection opening from the outside into the box The wires are marked with numbers Secure the cables in the electrical clamp strip according to the numberings See fig right Tighten the screw connection of the cable realisation and screw t...

Страница 3: ...p off Pump needs to be cooled No electricity Check electrical connections Pump runs Pump capacity slows down or stops Pump is inserted to deep Insert pump not so deep Hose connections systems have a leak Check hose connection systems Impeller wheel is worn down Change impeller wheel Filter has become dirty Clean filter When you turn on the pump the FI switch triggered Pump leaks examine pump moist...

Страница 4: ...er Schutz schalter Box Führen Sie das Kabel durch die dafür vorgesehene Verschraubung von außen in die Box Die Drähte sind mit Zahlen markiert Schließen Sie diese an die elektr Klemmleiste entsprechend der Nummerierung an Siehe Abb rechts Ziehen Sie die Verschraubung der Kabeldurchführung fest und verschrauben Sie den Deckel Achten Sie dabei auf den ordentlichen Sitz der Deckelgummidichtung Flexib...

Страница 5: ...Person zur Aufbewahrung der technischen Dokumente 1A Profi Handels GmbH Unterriethstraße 37 D 65187 Wiesbaden Richtlinie Niederspannung 2006 95 EG Richtlinie Elektromagnetische Verträglichkeit 2004 108 EG Folgende harmonisierte Normen EN ISO12100 2010 EN 60204 1 206 A1 2009 EN809 1998 A1 2009 EN60335 1 2002 A1 2004 A2 2006 A12 2006 A13 2008 A14 2010 A15 2011 EN60335 2 41 2003 A1 2004 2 2010 EN5501...

Страница 6: ...artikelgröße 0 2 mm 0 2 mm 0 2 mm Protection grade Schutzklasse IPX8 IPX8 IPX8 Electrical tension Spannung 230V 50 Hz 230V 50 Hz 230V 50 Hz Connection pressure side IT Anschluss Druckseite IG 1 IG 1 IG 1 IG Diameter Durchmesser 32 mm 98 5 mm 78 mm Height Höhe tba folgt tba folgt 53 cm Weight Gewicht 13 kg 16 kg 12 kg Cable length Kabellänge 15 m 15 m 15 m Thermal protector switch box only applicab...

Отзывы: