6.  This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety 

shutoff system. The ODS shuts down the heater if not enough fresh air is available. See 

Air for Combustion and 

Ventilation

, pages 5 through 7. If heater keeps shutting off, see 

Troubleshooting

, pages 15 through 17. 

7.   Do not run heater: 

·

 

Where flammable liquids or vapors are used or stored. 

·

 

Under dusty conditions. 

8.   Do not use this heater to cook food or burn paper or other objects. 

9.  Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the 

heater and replace any part of the control system and any gas control which has been under water. 

10.  Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. 

11.  Operating heater above elevations of 4,500 feet could cause pilot outage. 

12.  To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 

QUALIFIED INSTALLING AGENCY 

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment 
shall be performed only by a qualified agency. The term 

qualified agency

 means any individual, firm, corporation, or 

company that either in person or through a representative is engaged in and is responsible for:  

a)  The installation, testing, or replacements of gas piping or

 

b)  The connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is 

familiar with all precautions required; and that has complied with all the requirement of the authority having 
jurisdiction.  

 

PRODUCT FEATURES 
 
SAFETY PILOT 

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. 
The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off 
the heater if there is not enough fresh air.  

 
DUAL FUEL CAPABLE 

Your Fireplace is equipped to operate on either Propane or Natural gas. The fireplace is 
shipped from the factory ready for connecting to Propane. The fireplace can easily be 
changed to Natural gas by having your qualified installer follow the instructions on page 
9 & 10 and the markings on the fireplace.

 

 

LOCAL CODES 

 

Install and use heater with care. Follow all codes. In the absence of local codes, use the 
latest edition of 

The National Fuel Gas Code

,  ANSI Z 223.1, also known as NFPA 54*.  

*Available from:  
 

American National Standards lnstitute, lnc. 

 

1430 Broadway 

 

New York, NY 10018  

 

 

 

National Fire Protection Association, lnc. 

 

1 Batterymarch Park 

 

Quincy, MA 02269 

This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.  

State of Massachusetts:

 The 

installation must be made by 
a licensed plumber or gas 
fitter in the Commonwealth of 
Massachusetts. Sellers of 
unvented propane or natural 
gas-fired supplemental room 
heaters shall provide to each 
purchaser a copy of 527 CMR 
30 upon sale of the unit. 
 
In the State of Massachusetts, 
unvented propane or natural 
gas-fired space heaters shall 
be prohibited in bedrooms 
and bathrooms. 

 

In the State of 
Massachusetts the gas 
cock must be a T-handle 
type. The State of 
Massachusetts requires 
that a flexible appliance 
connector cannot 
exceed three feet in 
length.

 

Содержание RD-C

Страница 1: ...use with other gases Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not...

Страница 2: ...ly before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS ITEM NO RD C Input Rating 20000 BTU Hr 20000...

Страница 3: ...nge to this fireplace or its controls can be dangerous WARNING Do not allow fans or any other drafts that alter burner flame to blow directly into the heater They create drafts that alter burner flame...

Страница 4: ...iar with all precautions required and that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sen...

Страница 5: ...tructions to insure proper fresh air for this and other fuel burning appliances in your home PRODUCING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANSI Z 223 1...

Страница 6: ...u ft 51 2 or 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater ______________Btu Hr Gas water heater ______________Btu Hr Gas fu...

Страница 7: ...r use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your primary heat source If you have a central heating system you may run system s circu...

Страница 8: ...talled INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge conn...

Страница 9: ...into gas piping and or fittings NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas CAUTION Two gas line installation at the same time is forbidden You are not allowed to o...

Страница 10: ...ap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening gas supply tank valve 4 Check all joints of gas supp...

Страница 11: ...Check all joints from gas meter to equipment shutoff valve see Figure 11 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks immediately FASTENING HEA...

Страница 12: ...firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall are as between studs or solid walls concrete or masonry 1 Drill holes at marked locat...

Страница 13: ...attery with the anode pointing out Replace cap 3 Make sure equipment shutoff valve is fully open 4 Turn control knob clockwise to the OFF position See Figure 17 5 Wait five 5 minutes to clear out any...

Страница 14: ...m may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any comfort level bet...

Страница 15: ...ir though the ports slots and holes in the burner Also clean the pilot assembly A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole abou...

Страница 16: ...rol knob for 30 seconds to remove air Repeat igniting operation until air is removed 4 Clean ODS pilot see Cleaning and Maintenance page 15 or replace ODS pilot assembly 5 Check inlet gas pressure or...

Страница 17: ...rs of operation Heater produces a whistling noise when burner is lit 1 Turning control knob to HIGH 5 position when burner is cold 2 Air in gas line 3 Air passageways on heater are blocked 4 Dirty or...

Страница 18: ...r Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we w...

Страница 19: ...T NUMBER DESCRIPTION QUANTITY 1 RV83F1 L S REGULATOR 1 4 W20DT023 ODS OUTLET TUBE 1 1 5 HHY 00 SELECTION VALVE 1 6 W20DT020 OUTLET TUBE 1 7 W20DT022 ODS OUTLET TUBE 2 1 8 W20DT021 ODS INLET TUBE 1 9 W...

Страница 20: ...1 4 W20DT004 UPPER GLASS RETAINER 1 5 W20DT014 LOWER GLASS RETAINER 1 6 W20DT006 FLAT GLASS 1 7 W20DT140 REFLECTOR ASSEMBLY 1 8 W20DT200 BURNER ASSEMBLY 1 9 W20DT005 TOP PANEL 1 10 W20DT009 BOTTOM PA...

Отзывы: