Procom RD-C Скачать руководство пользователя страница 14

 

14 

OPERATING  

Continued 

 

Note:

 If pilot goes out, repeat steps 3 through 8. This heater has a safety interlock system. Wait one (1) minute before 

lighting pilot again. 

8.  Turn control knob counterclockwise 

 to desired heating level. The main burner should light. Set control knob to 

any heat level between 1 and 5. 

 

 

CAUTION:  

Do not try to adjust heating levels by using the equipment shutoff valve. 

 

THERMOSTATIC CONTROL OPERATION 

The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the 
burner on and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the 
set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set 
temperature. The control knob can be set to any comfort level.  

Note: 

The thermostat sensing bulb measures the temperature (depending on housing construction,  

The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the 
burner on and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the 
set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set 
temperature. The control knob can be set to any comfort level between HIGH (5) and LOW (1). 
 

 TO TURN OFF GAS APPLIANCE 

 

Shutting Off Heater 

1.  Turn control knob clockwise 

 to the OFF position.

 

 

INSPECTING BURNER  

Check pilot flame pattern and burner flame pattern 

 

PILOT FLAME PATTERN 

 

1. 

Turn

 

control knob to pilot position 

2. 

Inspect pilot flame and refer to Figure 19 and 20.  

·

 

Figure 19 shows a correct pilot flame pattern.  

·

 

Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame 
is not touching the thermocouple. This will cause the thermocouple to cool. 
When the thermocouple cools, the heater will shut down. 

·

 

If the pilot flame is incorrect, as shown in Figure 20.   
Turn heater off (see 

To Turn Off Gas to Appliance,

 page 14) 

See 

Troubleshooting

, page 15 through 17. 

 

BURNER FLAME PATTERN  

Figure 21 shows a correct burner flame pattern. Figure 22 shows an incorrect burner flame pattern. If pilot flame pattern is 
incorrect, as shown in Figure 22:  

·

 

turn heater off (see 

To Turn Off Gas to Appliance,

 page 14).  

·

 

see 

Troubleshooting

, pages 15 through 17. 

 

 

 

 

 

Figure 20 

 Incorrect Pilot Flame Pattern 

Figure 22 

 Incorrect Burner Flame Pattern 

Figure 19 

 Correct Pilot Flame Pattern 

Figure 21 

 Correct Burner Flame Pattern 

Содержание RD-C

Страница 1: ...use with other gases Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not...

Страница 2: ...ly before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS ITEM NO RD C Input Rating 20000 BTU Hr 20000...

Страница 3: ...nge to this fireplace or its controls can be dangerous WARNING Do not allow fans or any other drafts that alter burner flame to blow directly into the heater They create drafts that alter burner flame...

Страница 4: ...iar with all precautions required and that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sen...

Страница 5: ...tructions to insure proper fresh air for this and other fuel burning appliances in your home PRODUCING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANSI Z 223 1...

Страница 6: ...u ft 51 2 or 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater ______________Btu Hr Gas water heater ______________Btu Hr Gas fu...

Страница 7: ...r use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your primary heat source If you have a central heating system you may run system s circu...

Страница 8: ...talled INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge conn...

Страница 9: ...into gas piping and or fittings NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas CAUTION Two gas line installation at the same time is forbidden You are not allowed to o...

Страница 10: ...ap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening gas supply tank valve 4 Check all joints of gas supp...

Страница 11: ...Check all joints from gas meter to equipment shutoff valve see Figure 11 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks immediately FASTENING HEA...

Страница 12: ...firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall are as between studs or solid walls concrete or masonry 1 Drill holes at marked locat...

Страница 13: ...attery with the anode pointing out Replace cap 3 Make sure equipment shutoff valve is fully open 4 Turn control knob clockwise to the OFF position See Figure 17 5 Wait five 5 minutes to clear out any...

Страница 14: ...m may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any comfort level bet...

Страница 15: ...ir though the ports slots and holes in the burner Also clean the pilot assembly A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole abou...

Страница 16: ...rol knob for 30 seconds to remove air Repeat igniting operation until air is removed 4 Clean ODS pilot see Cleaning and Maintenance page 15 or replace ODS pilot assembly 5 Check inlet gas pressure or...

Страница 17: ...rs of operation Heater produces a whistling noise when burner is lit 1 Turning control knob to HIGH 5 position when burner is cold 2 Air in gas line 3 Air passageways on heater are blocked 4 Dirty or...

Страница 18: ...r Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we w...

Страница 19: ...T NUMBER DESCRIPTION QUANTITY 1 RV83F1 L S REGULATOR 1 4 W20DT023 ODS OUTLET TUBE 1 1 5 HHY 00 SELECTION VALVE 1 6 W20DT020 OUTLET TUBE 1 7 W20DT022 ODS OUTLET TUBE 2 1 8 W20DT021 ODS INLET TUBE 1 9 W...

Страница 20: ...1 4 W20DT004 UPPER GLASS RETAINER 1 5 W20DT014 LOWER GLASS RETAINER 1 6 W20DT006 FLAT GLASS 1 7 W20DT140 REFLECTOR ASSEMBLY 1 8 W20DT200 BURNER ASSEMBLY 1 9 W20DT005 TOP PANEL 1 10 W20DT009 BOTTOM PA...

Отзывы: