Procom RD-C Скачать руководство пользователя страница 20

 

20 

PARTS LIST 
RD-C 

 
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed 
under Replacement Parts on 18 of this manual. 

 

KEY NO 

PART NUMBER 

DESCRIPTION 

QUANTITY 

W20DT402-1 

LEFT/RIGHT DECORATIVE PANEL 

W20DT120 

FRONT PANEL ASSEMBLY 

W20DT003 

THERMAL INSULATION PANEL 1 

W20DT004 

UPPER GLASS RETAINER 

W20DT014 

LOWER GLASS RETAINER 

W20DT006 

FLAT GLASS 

W20DT140 

REFLECTOR ASSEMBLY 

W20DT200 

BURNER ASSEMBLY 

W20DT005 

TOP PANEL 

10 

W20DT009 

BOTTOM PANEL 

11 

W20DT100 

CABINET TOP 

12 

W20DT180 

CABINET 

13 

W20DT007 

WALL MOUNTING BRACKET 

14 

AL091-01 

IGNITOR 

15 

W20DT002 

VALVE COVER 

16 

W20DT401-01 

TOP DECORATIVE PANEL 

17 

W20DT403-01 

BOTTOM DECORATIVE PANEL 

18 

W20DT012 

WARNING PLATE 

19 

W20DT015 

THERMAL INSULATION PANEL 2 

20 

W20DT016 

THERMAL INSULATION PANEL 3 

 

 

Содержание RD-C

Страница 1: ...use with other gases Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not...

Страница 2: ...ly before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS ITEM NO RD C Input Rating 20000 BTU Hr 20000...

Страница 3: ...nge to this fireplace or its controls can be dangerous WARNING Do not allow fans or any other drafts that alter burner flame to blow directly into the heater They create drafts that alter burner flame...

Страница 4: ...iar with all precautions required and that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sen...

Страница 5: ...tructions to insure proper fresh air for this and other fuel burning appliances in your home PRODUCING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANSI Z 223 1...

Страница 6: ...u ft 51 2 or 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free heater ______________Btu Hr Gas water heater ______________Btu Hr Gas fu...

Страница 7: ...r use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your primary heat source If you have a central heating system you may run system s circu...

Страница 8: ...talled INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge conn...

Страница 9: ...into gas piping and or fittings NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas CAUTION Two gas line installation at the same time is forbidden You are not allowed to o...

Страница 10: ...ap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening gas supply tank valve 4 Check all joints of gas supp...

Страница 11: ...Check all joints from gas meter to equipment shutoff valve see Figure 11 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks immediately FASTENING HEA...

Страница 12: ...firmly fastened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall are as between studs or solid walls concrete or masonry 1 Drill holes at marked locat...

Страница 13: ...attery with the anode pointing out Replace cap 3 Make sure equipment shutoff valve is fully open 4 Turn control knob clockwise to the OFF position See Figure 17 5 Wait five 5 minutes to clear out any...

Страница 14: ...m may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any comfort level bet...

Страница 15: ...ir though the ports slots and holes in the burner Also clean the pilot assembly A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole abou...

Страница 16: ...rol knob for 30 seconds to remove air Repeat igniting operation until air is removed 4 Clean ODS pilot see Cleaning and Maintenance page 15 or replace ODS pilot assembly 5 Check inlet gas pressure or...

Страница 17: ...rs of operation Heater produces a whistling noise when burner is lit 1 Turning control knob to HIGH 5 position when burner is cold 2 Air in gas line 3 Air passageways on heater are blocked 4 Dirty or...

Страница 18: ...r Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we w...

Страница 19: ...T NUMBER DESCRIPTION QUANTITY 1 RV83F1 L S REGULATOR 1 4 W20DT023 ODS OUTLET TUBE 1 1 5 HHY 00 SELECTION VALVE 1 6 W20DT020 OUTLET TUBE 1 7 W20DT022 ODS OUTLET TUBE 2 1 8 W20DT021 ODS INLET TUBE 1 9 W...

Страница 20: ...1 4 W20DT004 UPPER GLASS RETAINER 1 5 W20DT014 LOWER GLASS RETAINER 1 6 W20DT006 FLAT GLASS 1 7 W20DT140 REFLECTOR ASSEMBLY 1 8 W20DT200 BURNER ASSEMBLY 1 9 W20DT005 TOP PANEL 1 10 W20DT009 BOTTOM PA...

Отзывы: