INSTALLATION

CONNECTING TO GAS SUPPLY

       WARNING:  A  qualified
service  person  must  connect
heater  to  gas  supply. Follow  all
local  codes.

           WARNING:  This  appliance
requires  a  3/8

"

  NPT  (National

Pipe  Thread)  inlet  connection
to  the  pressure  regulator.

          WARNING:  Never  connect
heater  to  private (non-utility)  gas
well. This  gas  is  commonly
known as  well-head  gas.

IMPORTANT:  Check  your  gas  line
pressure  before  connecting  heater
to  gas  line. Gas  line  pressure  must
be no greater than 14  inches of
water.  If  gas  line pressure  is  higher,
heater  regulator  damage  could
occur.

       CAUTION:  Use  only  new,
b l a c k   i r o n     o r   s t e e l     p i p e .
Internally-tinned  copper  tubing
may  be  used  in  certain  areas.
Check   your  local  codes.  Use pipe
of  large  enough   diameter to
allow  proper  gas  volume  to heater.
I f       p i p e       i s       t o o       s m a l l ,
undue  loss  of pressure  will
occur.  

Typical  Inlet  Pipe  Diameters
MN300HGA/MN300TGA  1/2”  or
greater

Installation   must   include  an
equipment   shutoff   valve,   union,
and  plugged  1/8

"

 NPT  tap.  Locate

NPT tap within  reach  for  test  gauge
hook   up.   NPT  tap  must  be up
stream  from  heater  (see  Figure
13).

*A  CSA/AGA  design-certified  equipment  shutoff  valve  with  1/8

"

  NPT  tap  is

an  acceptable  alternative  to  test  gauge  connection.  Purchase the  optional
C S A / A G A    d e s i g n - c e r t i f i e d     e q u i p m e n t     s h u t o f f     v a l v e     f r o m
your  dealer.  See  Accessories,  page 17.

IMPORTANT:  Install  an  equipment
shutoff  valve  in  an  accessible
location. The  equipment  shutoff
valve   is  for  turning  on  or  shutting
off  the  gas  to  the  appliance.

Apply  pipe  joint  sealant  lightly  to
male  threads.  This  will  prevent
excess  sealant  from  going  into
pipe.  Excess  sealant  in  pipe  could
result  in  clogged  heater  valves.

Install  sediment  trap  in  supply  line
as  shown  in  Figure 13.  Locate
sediment  trap  where  it  is  within
r e a c h       f o r     c l e a n i n g .     L o c a t e
sediment    trap   where   trapped
matter  is  not  likely  to  freeze.  A
sediment   trap  traps  moisture  and
contaminants.  This   keeps  them
from  going  into  heater  controls.  If
sediment  trap  is  not  installed    or  is
i n s t a l l e d     w r o n g ,     h e a t e r     m a y
not  run  properly.

IMPORTANT:    Hold   pressure
r e g u l a t o r     w i t h     w r e n c h     w h e n
connecting it to gas piping and/or
fittings.

           CAUTION:   Use   pipe   joint
sealant  that  is  resistant  to
natural  gas.

Figure 13 -Gas  Connection

www.PartsFor.com   1-800-446-1446

For replacement parts contact:

1-866-607-2787

Содержание MN300HGA

Страница 1: ...y a qualified installer service agency or gas supplier Important Safety Information 2 Fresh Air for Combustion and Ventilation 4 Installation 8 Operating Your Heater 11 Cleaning Maintenance 13 Trouble...

Страница 2: ...ner or similar products If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 9 Do not use heater if any part has been under wa...

Страница 3: ...otective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater Figure1 Vent Free Natural Gas Heater Model...

Страница 4: ...s described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for com...

Страница 5: ...free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Dir...

Страница 6: ...sediment trap tee joint pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design cer...

Страница 7: ...Remove two screws near bottom corners of lower front panel 2 Pull bottom of lower front panel forward then down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each e...

Страница 8: ...anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater on Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 11 2 Place heater onto m...

Страница 9: ...p stream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certif...

Страница 10: ...Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heate...

Страница 11: ...o desired heating Level The main burner should light Set control knob to any heat level between HI and LO THERMOSTAT CONTROL OPERATION This increases or decreases the burner flame height At times the...

Страница 12: ...s Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you don t smell gas g o t o t h e n e x t s t e p 5 Push in and turn con...

Страница 13: ...me comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 24 Pilot...

Страница 14: ...rmocouple connection is loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of...

Страница 15: ...ooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orific...

Страница 16: ...ors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogg...

Страница 17: ...your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Warranty Card Usually we will ask you to return th...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN MN300TGA ODS Pilot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 19: ...S AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Middle Panel Grill Guard Assembly Self Tapping Screw Thermostat Valve Assembly Screws The...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN MN300HGA ODS Pllot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 21: ...Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Grill Guard Assembly Middle Panel Ignitor Assembly Self Tapping Screw Control Valve Ignitor Line Control Knob Control Valv...

Отзывы: