Procom MN300HGA Скачать руководство пользователя страница 11

      1 1

Figure 16 - Control  Knob  in  The
OFF  Position

Figure 17 - Pilot

THERMOSTAT  MODEL
MN300TGA

LIGHTING

INSTRUCTIONS

1.  STOP!   Read    the   safety
    information  on  the  side of
       heater.
2.    Check    that     gas    supply    to
       heater  is  on.
3.  Push  in  gas  control  knob
       slightly  and  turn  clockwise
       to  the  OFF  position.
NOTE:   knob  cannot  be  turned from
“PILOT”  to  “OFF”  unless knob  is
p u s h e d     i n     s l i g h t l y .   D o     n o t
force.
4.   Wait five (5) minutes  to  clear
      out   any   air. Then   smell  for
       gas,  including  near  the  floor.
        If      you      smell     gas,    STOP!
       Follow   “B”     in     the     safety
        information  on  the  side of  the
       heater.  If   you   do   not   smell
       gas,  go  to  the  next  step.
5.    Push     in    gas   control   knob
      slightly   and    turn   

  counter-

       clockwise      to    the   “PILOT/IGN”
    position  and  depress  for
        five(5) seconds
NOTE:   The  first  time  that  the
h e a t e r       i s     o p e r a t e d     a f t e r
connecting  the  gas  supply ,  the
control  knob  should  be  depressed
for  about  thirty (30) seconds.  This
will   allow  air  to  bleed   from  the  gas
system.
 6.    With  control  knob  pressed  in,
       push  down  and   release   the
     ignitor button. This  will  light
        pilot.  If   needed,  keep   pressing
       ignitor   button  until  pilot  lights.
NOTE:  If   pilot   does   not   stay   lit,
refer  to  Troubleshooting,  pages  14
through 16.  Also  contact  a  qualified
service person  or  gas  supplier   for
repairs. Until  repairs are  made,  light
pilot   with   match. To  light  pilot  with
match,   see   Manual    Lighting
Procedure.

7.   Keep  control  knob  pressed  in
     for  thirty  (30)  seconds  after
       lighting       pilot.         After       30
       seconds,  release  control  knob.

 

If   control   knob  does   not   pop

     up  when  released,  contact  a
      qualified     service    person    or
       gas  supplier  for  repairs.
NOTE:   If  pilot  goes  out,  repeat
steps 3 through 7. Wait one (1)
minute  before  lighting  pilot  again
8.   Turn             control            knob
     counterclockwise                 to
      desired    heating    Level.   The
      main  burner  should  light.  Set
      control  knob  to  any  heat  level
       between  HI  and  LO.

THERMOSTAT

CONTROL

OPERATION

This  increases  or  decreases   the
burner  flame height.  At  times  the  room
may exceed  the  set  temperature.  If
so, the  burner  will  shut  off.  The  burner
will  cycle  back  on  when room  tem-
perature  drops   below  the set
temperature. The   control knob  can  be
set  to  any  heat  level between  HI and
LO. Selecting  the HI  setting  will  cause
the  burner  to remain  fully  on  without
modulating   down   in  most cases.
NOTE:    the   thermostat sensing
bulb  measures  the  temperature
of air  near  the  heater  cabinet.
This may  not  always   agree   with
r o o m     t e m p e r a t u r e   ( d e p e n d i n g
o n     h o u s i n g     c o n s t r u c t i o n .
installation  location,  room  size,
o p e n     a i r     t e m p e r a t u r e s ,   e t c . ) .
frequent  use  of  your  heater  will
let  you  determine  your  own
comfort  levels.

TO TURN OFF

GAS TO APPLIANCE

Shutting  Off  Heater
1.   Turn  control  knob  clockwise

         

  to  the  OFF  position.

2.     Turn  off  all   electric   power   to
       the  appliance  if  service  is  to
        be  performed.

SHUTTING OFF BURNER ONLY
(PILOT STAYS LIT)

Turn   control   knob   clockwise  

   to

the  PILOT/IGN  position

MANUAL LIGHTING

PROCEDURE

1.     Remove  lower  front  panel (see
        Figure 7 page 7).
2.   Follow   steps   1   through  5
        under Lighting Instructions.
3.     With   control   knob   pressed  in,
        strike    match.    Hold   match    to
        pilot until pilot lights.
4.    Keep  control  knob  pressed  in
      for 30  seconds  after lighting
        pilot.  After  30  seconds, release
      control   knob.  Follow   step  8
        under  Lighting  Instructions.
5.     Replace   lower  front   panel.

OPERATING  YOUR  HEATER

The  thermostatic  control  used  on
these  models  differs from  standard
thermostats.  Standard   thermostats
simply  turn  on  and  off  the  burner.The
thermostat  used  on  this  heater
senses  the  room   temperature.  The
thermostat     adjusts     the    amount
of    gas    flow     to     the       burner.

www.PartsFor.com   1-800-446-1446

For replacement parts contact:

1-866-607-2787

Содержание MN300HGA

Страница 1: ...y a qualified installer service agency or gas supplier Important Safety Information 2 Fresh Air for Combustion and Ventilation 4 Installation 8 Operating Your Heater 11 Cleaning Maintenance 13 Trouble...

Страница 2: ...ner or similar products If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 9 Do not use heater if any part has been under wa...

Страница 3: ...otective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater Figure1 Vent Free Natural Gas Heater Model...

Страница 4: ...s described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for com...

Страница 5: ...free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Dir...

Страница 6: ...sediment trap tee joint pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design cer...

Страница 7: ...Remove two screws near bottom corners of lower front panel 2 Pull bottom of lower front panel forward then down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each e...

Страница 8: ...anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater on Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 11 2 Place heater onto m...

Страница 9: ...p stream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certif...

Страница 10: ...Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heate...

Страница 11: ...o desired heating Level The main burner should light Set control knob to any heat level between HI and LO THERMOSTAT CONTROL OPERATION This increases or decreases the burner flame height At times the...

Страница 12: ...s Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you don t smell gas g o t o t h e n e x t s t e p 5 Push in and turn con...

Страница 13: ...me comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 24 Pilot...

Страница 14: ...rmocouple connection is loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of...

Страница 15: ...ooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orific...

Страница 16: ...ors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogg...

Страница 17: ...your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Warranty Card Usually we will ask you to return th...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN MN300TGA ODS Pilot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 19: ...S AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Middle Panel Grill Guard Assembly Self Tapping Screw Thermostat Valve Assembly Screws The...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN MN300HGA ODS Pllot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 21: ...Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Grill Guard Assembly Middle Panel Ignitor Assembly Self Tapping Screw Control Valve Ignitor Line Control Knob Control Valv...

Отзывы: