Procom MN300HGA Скачать руководство пользователя страница 10

    1 0

Figure 14 -Equipment  Shutoff  Valve

INSTALLATION

CHECKING GAS
CONNECTIONS

            WARNING:    Test  all  gas
piping   and  connections  for  leaks after
installing  or  servicing.   Correct   all
leaks   at   once.

           WARNING:   Never  use  an  open
flame   to   check   for  a   leak. Apply   a
mixture   of   liquid   soap and   water
to   all   joints.  Bubbles forming
show  a leak.  Correct  all   leaks  at
once.

Pressure  Testing  Gas  Supply
Piping  System
Test  Pressures  In  Excess  Of
1/2  PSIG  (3.5 K Pa)

1.   Disconnect   appliance   with   its
       appliance       main        gas     valve
     (control valve)   and   equipment
      shutoff    valve   from   gas   supply
     piping  system.  Pressures  in
       excess  of   1/2  psig  will  damage
      heater  regulator.
2.    Cap   off  open   end   of   gas  pipe

where  equipment  shutoff  valve

       was   connected.
3.     Pressurize             supply           piping

s y s t e m     b y     e i t h e r   u s i n g
compressed   air   or    opening

      main  gas  valve  located  on  or

near  gas  meter.

4.   Check  all  joints  of  gas  supply

piping  system.  Apply  mixture  of
liquid  soap  and  water  to  gas
joints. Bubbles  forming  show

      a  leak.
5.   Correct  all  leaks  at  once.
6.   Reconnect heater and equipment
       shutoff  valve  to  gas supply.  Check

reconnected   fittings  for  leaks.

Test  Pressures  Equal  To or
Less  Than  1/2  PSIG  (3.5 K Pa)

1.   Close equipment  shutoff  valve
       (see Figure 14).
2.   Pressurize  supply  piping  system
      by  either  using  compressed  air
      or    opening    main    gas   valve
      located  on  or  near  gas  meter.
3.   Check  all  joints  from  gas  meter to
    equipment  shutoff  valve  (see
    Figure 15).  Apply mixture  of
     liquid  soap and  water  to  gas
     joints.  Bubbles  forming show
      a leak.
4.   Correct  all  leaks  at  once.

Pressure  Testing  Heater  Gas
Connections

1.  Open  equipment  shutoff  valve
      (see  Figure  14).
2.   Open   main  gas  valve  located  on
      or  near  gas  meter.
3.   Make    sure    control    knob    of
      heater  is  in  the  OFF position.
4.   Check  all  joints  from  equipment
      shutoff   valve   to   control   valve
      (see Figure 15 ).  Apply  mixture  of
        liquid   soap    and    water  to   gas
     joints. Bubbles  forming  show
      a  leak.
5.   Correct all leaks at once.
6.   Light    heater    (see   Operating

Heater,  pages  11  for  thermostat
m o d e l     o r       p a g e     1 2       f o r

      non-thermostat model). Check

the  rest  of  the internal  joints  for

      leaks.
7.   Turn  off  heater (see  To  Turn  Off

Gas  To  Appliance,  page 11  for
thermostat  model  or  page  12

       for  non-thermostat  model).
8.    Replace  lower  front  panel.

    THERMOSTAT  MODEL
                MN300TGA

FOR YOUR SAFETY

READ BEFORE LIGHTING

            WARNING:   If  you  do  not
f o l l o w       t h e s e       i n s t r u c t i o n s
exactly, a  fire  or  explosion  may
r e s u l t       c a u s i n g       p r o p e r t y
damage,   personal   injury    or
loss  of  life.

A.    This   appliance  has  a  pilot  which
     must    be   lighted   by   hand.
     When  lighting  the  pilot,  follow
      these  instructions  exactly.
B.  BEFORE  LIGHTING  smell  all
     around   the  appliance  area  for
     gas.  Be  sure  to  smell  next  to
      the  floor  because  some  gas  is
     heavier  than  air  and  will  settle
      on the  floor .

WHAT TO DO IF YOU SMELL GAS

 

Do  not  try  to  light any  appliance.

 

Do not touch any electric switch;

    do not use any phone in your
       building.

 

Immediately       call      your     gas

    supplier from  a  neighbor’s
       phone.     Follow        the        gas
       supplier’s   instructions.

 

If     you     cannot    reach     your

    gas  supplier,  call   the  fire
      department.

C.  Use  only  your  hand  to  push  in
     or  turn  the   gas   control  knob.
     Never   use   tools.  If   the   knob
    will  not  push  in  or  turn  by
      hand, don’t  try  to  repair  it, call
     a qualified service technician or
      gas supplier. Force or attempted
    repair may result in  a fire or
      explosion.
D.  Do not use this appliance if any
      p a r t   h a s   b e e n   u n d e r   w a t e r .
    Immediately  call  a  qualified
     service  technician   to   inspect
      the  appliance   and   to   replace
      any  part  of  the  control  system
     and any gas control which has
      been  under  water.

Figure 15 -Checking  Gas  Joints

OPERATING YOUR HEATER

www.PartsFor.com   1-800-446-1446

For replacement parts contact:

1-866-607-2787

Содержание MN300HGA

Страница 1: ...y a qualified installer service agency or gas supplier Important Safety Information 2 Fresh Air for Combustion and Ventilation 4 Installation 8 Operating Your Heater 11 Cleaning Maintenance 13 Trouble...

Страница 2: ...ner or similar products If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 9 Do not use heater if any part has been under wa...

Страница 3: ...otective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater Figure1 Vent Free Natural Gas Heater Model...

Страница 4: ...s described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for com...

Страница 5: ...free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Dir...

Страница 6: ...sediment trap tee joint pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design cer...

Страница 7: ...Remove two screws near bottom corners of lower front panel 2 Pull bottom of lower front panel forward then down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each e...

Страница 8: ...anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater on Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 11 2 Place heater onto m...

Страница 9: ...p stream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certif...

Страница 10: ...Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heate...

Страница 11: ...o desired heating Level The main burner should light Set control knob to any heat level between HI and LO THERMOSTAT CONTROL OPERATION This increases or decreases the burner flame height At times the...

Страница 12: ...s Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you don t smell gas g o t o t h e n e x t s t e p 5 Push in and turn con...

Страница 13: ...me comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 24 Pilot...

Страница 14: ...rmocouple connection is loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of...

Страница 15: ...ooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orific...

Страница 16: ...ors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogg...

Страница 17: ...your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Warranty Card Usually we will ask you to return th...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN MN300TGA ODS Pilot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 19: ...S AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Middle Panel Grill Guard Assembly Self Tapping Screw Thermostat Valve Assembly Screws The...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN MN300HGA ODS Pllot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 21: ...Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Grill Guard Assembly Middle Panel Ignitor Assembly Self Tapping Screw Control Valve Ignitor Line Control Knob Control Valv...

Отзывы: