Procom MN300HGA Скачать руководство пользователя страница 1

   1

B L U E   F L A M E   V E N T - F R E E

NATURAL   G A S   G A R A G E

HEATER

OWNER

S OPERATION AND INSTALLATION MANUAL

MN300HGA

MN300TGA

NON-THERMOSTAT  AND

THERMOSTAT  MODEL

        WA R N I N G :     I m p r o p e r       i n s t a l l a t i o n ,
adjustment, alteration, service  or  maintenance
can  cause  injury  or  property  damage. Refer  to
this  manual  for  correct  installation  and
operational  procedures.  For  assistance  or
additional  information  consult  a  qualified
installer,  service  agency,  or  gas  supplier.

This  appliance  may  be  installed  in  an  aftermar-
ket*  permanently  located, manufactured
(mobile) home, where  not  prohibited  by  local
codes.
This appliance  is  only  for  use  with  the  type  of
gas  indicated  on  the  rating  plate. This
appliance  is  not  convertible  for  use  with  other
gases.

Do  not  store,  or  use  gasoline  or  other  flammable
vapors  and  liquids  in  the  vicinity  of  this  or  any
other  appliance.
WHAT  TO  DO  IF  YOU  SMELL  GAS

 

Do  not  try  to  light  any  appliance.

 

Do   not    touch   any   electrical   switch;  do  not

       use  any  phone  in   your  building.

 

Immediately   call   your  gas  supplier  from  a

       neighbor’s   phone.   Follow   the   gas   supplier’s
       instructions.

 

If   you   cannot  reach  your  gas  supplier, call

       the  fire  department.
Installation  and  service  must  be  performed  by  a
q u a l i f i e d     i n s t a l l e r ,   s e r v i c e     a g e n c y    o r      g a s
supplier.

Important Safety Information..................................... 2

Fresh Air for Combustion and Ventilation ............... 4

Installation..................................................................... 8

Operating Your Heater............................................... 11

Cleaning&Maintenance.............................................13

Trouble Shooting.........................................................14

Specifications..............................................................17

Illustrate Parts Breakdown MN300TGA  .................18

Parts List MN300TGA .................................................19

Illustrate Parts Breakdown MN300HGA  .................20

Parts List MN300HGA .................................................21

Table of Contents

    WARNING: 

 If  the  information  in this

manual  is  not  followed  exactly, a     f i r e     o r
e x p l o s i o n     m a y     r e s u l t  causing  property
damage,  personal injury,  or  loss  of  life.

    WARNING:   

This  is  an  unvented gas-fired

heater.  It  uses  air  (oxygen) f r o m     t h e     r o o m
i n     w h i c h     i t     i s  installed.  Provisions  for
adequate combustion  and  ventilation  air  must
b e     p r o v i d e d .     R e f e r     t o     A i r     F o r  Combustion
and  Ventilation section on  page  4  of  this
manual.

*Aftermarket: Completion  of  sale, not  for  purpose  of
resale,  from  the  manufacturer.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vaporis a by-product of gas combustion.An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU’s (.3KW’s)
of gas input per hour. Refer to page 3.

Installer: Please leave these instructions with
the consumer.

Consumer: Please retain these instructions for
future use.

5 Musick

Irvine

CA 92618

4600 Highlands  parkway S.E

SUITE # D/E

Smyrna, GA 30080

www.PartsFor.com   1-800-446-1446

For replacement parts contact:

1-866-607-2787

Содержание MN300HGA

Страница 1: ...y a qualified installer service agency or gas supplier Important Safety Information 2 Fresh Air for Combustion and Ventilation 4 Installation 8 Operating Your Heater 11 Cleaning Maintenance 13 Trouble...

Страница 2: ...ner or similar products If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 9 Do not use heater if any part has been under wa...

Страница 3: ...otective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater Figure1 Vent Free Natural Gas Heater Model...

Страница 4: ...s described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for com...

Страница 5: ...free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Dir...

Страница 6: ...sediment trap tee joint pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design cer...

Страница 7: ...Remove two screws near bottom corners of lower front panel 2 Pull bottom of lower front panel forward then down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each e...

Страница 8: ...anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater on Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 11 2 Place heater onto m...

Страница 9: ...p stream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certif...

Страница 10: ...Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heate...

Страница 11: ...o desired heating Level The main burner should light Set control knob to any heat level between HI and LO THERMOSTAT CONTROL OPERATION This increases or decreases the burner flame height At times the...

Страница 12: ...s Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you don t smell gas g o t o t h e n e x t s t e p 5 Push in and turn con...

Страница 13: ...me comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 24 Pilot...

Страница 14: ...rmocouple connection is loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of...

Страница 15: ...ooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orific...

Страница 16: ...ors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogg...

Страница 17: ...your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Warranty Card Usually we will ask you to return th...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN MN300TGA ODS Pilot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 19: ...S AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Middle Panel Grill Guard Assembly Self Tapping Screw Thermostat Valve Assembly Screws The...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN MN300HGA ODS Pllot Assembly www PartsFor com 1 800 446 1446 For replacement parts contact 1 866 607 2787...

Страница 21: ...Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Grill Guard Assembly Middle Panel Ignitor Assembly Self Tapping Screw Control Valve Ignitor Line Control Knob Control Valv...

Отзывы: