Procom FBNSD400RT-ZC Series Скачать руководство пользователя страница 5

www.usaprocom.com

5

200346-01A

SPECIFICATIONS

FBNSD400RT-ZC

Gas Type

Natural

Propane/LP

Maximum Input Rating 32,000 BTU/Hr 32,000 BTU/Hr

Minimum Input Rating

N/A

N/A

Regulator Pressure Setting

4" W.C.

9" W.C.

Inlet Gas Pressure*

 

(inches of water)

Max. 9.5" W.C.

Max. 14" W.C.

Min. 5" W.C.

Min. 11" W.C.

Ignition

Electronic Piezo Ignitor

Heater Dimensions (H x W x D)

29.5" x 29.1" x 15.6"

Carton Dimensions (H x W x D)

31.1" x 31.5" x 18.1"

Fireplace Weight

69.5 lbs.

Shipping Weight

79.5 lbs.

                      * For purposes of input adjustment.

QUALIFIED INSTALLING AGENCY

Only  a  qualified  agency  should  install  and 

replace gas piping, gas utilization equipment 

or accessories, and repair and equipment ser-

vicing. The term “qualified agency” means any 

individual, firm, corporation, or company that 

either in person or through a representative 

is engaged in and is responsible for:

  a) Installing, testing, or replacing gas piping 

or

  b) Connecting, installing, testing, repairing, 

or servicing equipment; that is experienced 

in such work; that is familiar with all precau-

tions required; and that has complied with 

all the requirement of the authority having 

jurisdiction.

PRODUCT FEATURES

SAFETY PILOT

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The 

ODS/pilot shuts off the heater if there is not 

enough fresh air.

PIEZO IGNITION SYSTEM

This  heater  is  equipped  with  an  electronic 

piezo  control  system. This  system  requires 

AAA batteries (provided).

THERMOSTAT HEAT CONTROL

The control automatically cycles the burner 

on and off to maintain a desired room tem-

perature.

2 GAS OPTIONS AVAILABLE

Your heater is equipped to operate on either 

Propane/LP  or  Natural  gas.  The  heater  is 

shipped from the factory ready for connect-

ing to Propane/LP. The heater can easily be 

changed to Natural gas by having your quali-

fied installer follow the instructions on page 

10 and the markings on the heater.

Содержание FBNSD400RT-ZC Series

Страница 1: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qu...

Страница 2: ...tion adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional informatio...

Страница 3: ...or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning Failure to follow these instructions will...

Страница 4: ...has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water SAFETY 10 T...

Страница 5: ...Installing testing or replacing gas piping or b Connecting installing testing repairing or servicing equipment that is experienced in such work that is familiar with all precau tions required and that...

Страница 6: ...alth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachuset...

Страница 7: ...erfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce...

Страница 8: ...n grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These...

Страница 9: ...or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the h...

Страница 10: ...bited CAUTION To avoid gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheins...

Страница 11: ...s the fitting is installed Make sure the type of gas being used is correct Check to make sure the connection fitting is in the correct inlet on the regula tor Refer to Connecting to Gas Supply page 14...

Страница 12: ...should not be less than 12 see Figure 5 B Clearance from the top of the fireplace to the ceiling must not be less than 48 BUILT IN FIREPLACE INSTALLATION WARNING Do not allow any combustiblematerialst...

Страница 13: ...Use dimensions shown in Figure 7 for the rough opening If installing in a corner use dimensions shown in Figure 9 for the rough opening The height is 23 1 4 which is the same as the wall opening above...

Страница 14: ...ptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater to gas supp...

Страница 15: ...Down External Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge...

Страница 16: ...aleak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control valve and equipment shu...

Страница 17: ...logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 Install pins on log 1 into the two slots in the bracket attached to rear wall see Figure 16 2...

Страница 18: ...eiver when it is not in use For long periods of non operation remove batteries from all components for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control AAA 2 or 3 Remote Receiver AA 4...

Страница 19: ...SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof ne...

Страница 20: ...ox to the OFF position then back to the ON position Note Please wait one minute after shut ting off heater to allow the control valve to reset before starting again 13 Make sure heater screen is in pl...

Страница 21: ...aged the slide switch on the receiver can be used to operate the heater Note When batteries are replaced the learning process above must be repeated LEARN REMOTE OFF ON Figure 23 Receiver Slide Switch...

Страница 22: ...he LCD screen will display the set temperature for 3 sec onds then flash the set temperature for 3 seconds then LCD screen will default to display the room temperature To Change The Set Temperature 1...

Страница 23: ...ping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame App...

Страница 24: ...irt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Rep...

Страница 25: ...re Wipe the cabinet to remove dust CARE AND MAINTENANCE Figure 33 Pilot Inlet Air Hole LOGS If you remove logs for cleaning refer to Installing Logs page 17 to properly replace logs Replace log s if b...

Страница 26: ...ass pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified ins...

Страница 27: ...ully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 24 or rep...

Страница 28: ...gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top of page 26 1 Contact a qualified servi...

Страница 29: ...resh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local gas supplier 3 Clean ODS pilot see Care and Maintenance page 24 Ga...

Страница 30: ...www usaprocom com 200346 01A 30 PARTS MODEL FBNSD400RT ZC 9 8 10 12 11 13 15 18 14 6 1 2 3 4 16 7 5 17 PILOT OFF ON RE MO TE OF F ON LEA RN TEMP 19...

Страница 31: ...AAA Battery 1 3 161333 01 AA Battery 4 Not a field replaceable part REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warrant...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...

Отзывы: