Procom FBNSD400RT-ZC Series Скачать руководство пользователя страница 17

www.usaprocom.com

17

200346-01A

INSTALLATION

INSTALLING LOGS

 WARNING: Failure to posi-

tion  the  parts  in  accordance 

with  these  diagrams  or  failure 

to  use  only  parts  specifically 

approved with this heater may 

result  in  property  damage  or 

personal injury.

 CAUTION: After installation 

and  periodically  thereafter, 

check to ensure that no yellow 

flame comes in contact with any 

log. With the heater set to High, 

check  to  see  if  yellow  flames 

contact  any  log.  If  so,  reposi-

tion  logs  according  to  the  log 

installation instructions in this 

manual. Yellow flames contact-

ing logs will create soot.

It is very important to install the 

logs  exactly  as  instructed.  Do 

not modify logs. Use only logs 

supplied with heater. Each log 

is marked with a number. This 

number will help you to identify 

the  logs  when  installing. After 

installing  logs,  add  decorative 

cinders around the grate base, 

do  not  place  any  decorative 

cinders on logs or burner.

1.  Install pins on log #1 into the two slots 

in the bracket attached to rear wall (see 

Figure 16).

2.  Install pins on log #2 into the two slots in 

left side of the middle bracket (see Figure 

16 and Figure 17).

3.  Install pins on log #3 into the two slots 

in  right  side  of  the  middle  bracket  (see 

Figure 16 and Figure 17).

4.  Install pins on log #4 onto the two slots 

in  the  front  bracket (see  Figure  17  and 

Figure 18, page 18).

5.  Insert the recessed hole on the bottom of 

log #5 onto the pin on log #2 (see Figures 

18 and 19, page 18).

Figure 16 - Installing Log #1

Figure 17 - Installing Logs #2 and #3

6.  Insert the pin on log #6 into the hole on 

log #3 (see Figures 18 and 19, page 18).

IMPORTANT: 

Make sure logs do not cover 

any burner ports. It is very important to install 

the logs exactly as instructed. Do not modify 

logs. Use only logs supplied with heater.

Slots in Rear Plate

Log #1

Log #2

Log #3

Slots for Log #2

Slots for Log #4

Slots for Log #3

Содержание FBNSD400RT-ZC Series

Страница 1: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qu...

Страница 2: ...tion adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional informatio...

Страница 3: ...or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning Failure to follow these instructions will...

Страница 4: ...has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water SAFETY 10 T...

Страница 5: ...Installing testing or replacing gas piping or b Connecting installing testing repairing or servicing equipment that is experienced in such work that is familiar with all precau tions required and that...

Страница 6: ...alth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachuset...

Страница 7: ...erfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce...

Страница 8: ...n grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These...

Страница 9: ...or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the h...

Страница 10: ...bited CAUTION To avoid gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheins...

Страница 11: ...s the fitting is installed Make sure the type of gas being used is correct Check to make sure the connection fitting is in the correct inlet on the regula tor Refer to Connecting to Gas Supply page 14...

Страница 12: ...should not be less than 12 see Figure 5 B Clearance from the top of the fireplace to the ceiling must not be less than 48 BUILT IN FIREPLACE INSTALLATION WARNING Do not allow any combustiblematerialst...

Страница 13: ...Use dimensions shown in Figure 7 for the rough opening If installing in a corner use dimensions shown in Figure 9 for the rough opening The height is 23 1 4 which is the same as the wall opening above...

Страница 14: ...ptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater to gas supp...

Страница 15: ...Down External Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge...

Страница 16: ...aleak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control valve and equipment shu...

Страница 17: ...logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 Install pins on log 1 into the two slots in the bracket attached to rear wall see Figure 16 2...

Страница 18: ...eiver when it is not in use For long periods of non operation remove batteries from all components for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control AAA 2 or 3 Remote Receiver AA 4...

Страница 19: ...SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof ne...

Страница 20: ...ox to the OFF position then back to the ON position Note Please wait one minute after shut ting off heater to allow the control valve to reset before starting again 13 Make sure heater screen is in pl...

Страница 21: ...aged the slide switch on the receiver can be used to operate the heater Note When batteries are replaced the learning process above must be repeated LEARN REMOTE OFF ON Figure 23 Receiver Slide Switch...

Страница 22: ...he LCD screen will display the set temperature for 3 sec onds then flash the set temperature for 3 seconds then LCD screen will default to display the room temperature To Change The Set Temperature 1...

Страница 23: ...ping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame App...

Страница 24: ...irt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Rep...

Страница 25: ...re Wipe the cabinet to remove dust CARE AND MAINTENANCE Figure 33 Pilot Inlet Air Hole LOGS If you remove logs for cleaning refer to Installing Logs page 17 to properly replace logs Replace log s if b...

Страница 26: ...ass pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified ins...

Страница 27: ...ully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 24 or rep...

Страница 28: ...gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top of page 26 1 Contact a qualified servi...

Страница 29: ...resh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local gas supplier 3 Clean ODS pilot see Care and Maintenance page 24 Ga...

Страница 30: ...www usaprocom com 200346 01A 30 PARTS MODEL FBNSD400RT ZC 9 8 10 12 11 13 15 18 14 6 1 2 3 4 16 7 5 17 PILOT OFF ON RE MO TE OF F ON LEA RN TEMP 19...

Страница 31: ...AAA Battery 1 3 161333 01 AA Battery 4 Not a field replaceable part REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warrant...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...