Procom FBNSD400RT-ZC Series Скачать руководство пользователя страница 18

www.usaprocom.com

200346-01A

18

INSTALLATION

Figure 18 - Installing Log #4

Figure 19 - Installing Log #5 and #6

Pin for Log #5

Log #5

Hole for Log #6

Log #6

Log #4

AA

AA

AA

AAA

AAA

AA

REMOTE

OFF

ON

LEARN

INSTALLING BATTERIES

 CAUTION: Do not mix old and 

new batteries. Do not mix alka-

line, standard (carbon - zinc), or 

rechargeable (nickel - cadmium) 

batteries.  Do  not  dispose  of 

batteries  in  fire,  batteries  may 

explode or leak.

•  Batteries are included.
•  Remove batteries when depleted.
•  Install/replace the batteries according to the 

type and quantity stated in table below.

•  Do not mix old and new batteries. New bat-

teries should be the same brand for best 

results.

•  Be  sure  to  observe  proper  polarity  (+/-) 

when installing or replacing the batteries. 

Damage due to improper battery installa-

tion may void the warranty on the product.

•  For remote control systems, maximize bat-

tery life by turning off the receiver when it 

is not in use.

•  For long periods of non-operation, remove 

batteries from all components for safety.

Component

Type of Battery

Qty.

Ignitor

AAA

1

Remote Control

AAA

2 or 3*

Remote Receiver

AA

4

*

Note: Quantity depends on model of remote 

control.

Ignitor

Unscrew ignitor cap and install a AAA battery 

with the + pointing out. Replace cap.

Figure 21 - Installing Batteries in Remote 

Control and Receiver

Receiver

Remote Control (Transmitter)

Figure 20 - Installing Battery in Ignitor

AAA

Battery

Positive

UP

Receiver and Remote Control

Batteries  are  required  in  both  the  Remote 

Control  (Transmitter)  (2 AAA  size)  and  Re-

ceiver (4 AA size) (see Figure 21).

Note: Be sure batteries are placed correctly. 

Reversing the batteries can cause damage to 

the receiver and remote. Replace all batteries 

on a yearly basis or sooner.

Position the slide switch on the front of the 

receiver box in the ON position before install-

ing batteries. Once the batteries are installed 

you will hear a single beep which indicates 

the batteries are charged. If you do not hear 

a beep, replace with new batteries.

Содержание FBNSD400RT-ZC Series

Страница 1: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qu...

Страница 2: ...tion adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For assistance or additional informatio...

Страница 3: ...or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning Failure to follow these instructions will...

Страница 4: ...has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water SAFETY 10 T...

Страница 5: ...Installing testing or replacing gas piping or b Connecting installing testing repairing or servicing equipment that is experienced in such work that is familiar with all precau tions required and that...

Страница 6: ...alth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachuset...

Страница 7: ...erfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce...

Страница 8: ...n grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These...

Страница 9: ...or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the h...

Страница 10: ...bited CAUTION To avoid gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheins...

Страница 11: ...s the fitting is installed Make sure the type of gas being used is correct Check to make sure the connection fitting is in the correct inlet on the regula tor Refer to Connecting to Gas Supply page 14...

Страница 12: ...should not be less than 12 see Figure 5 B Clearance from the top of the fireplace to the ceiling must not be less than 48 BUILT IN FIREPLACE INSTALLATION WARNING Do not allow any combustiblematerialst...

Страница 13: ...Use dimensions shown in Figure 7 for the rough opening If installing in a corner use dimensions shown in Figure 9 for the rough opening The height is 23 1 4 which is the same as the wall opening above...

Страница 14: ...ptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice technician must connect heater to gas supp...

Страница 15: ...Down External Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge...

Страница 16: ...aleak Correctallleaksatonce PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect heater with its appliance main gas valve control valve and equipment shu...

Страница 17: ...logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 Install pins on log 1 into the two slots in the bracket attached to rear wall see Figure 16 2...

Страница 18: ...eiver when it is not in use For long periods of non operation remove batteries from all components for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control AAA 2 or 3 Remote Receiver AA 4...

Страница 19: ...SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof ne...

Страница 20: ...ox to the OFF position then back to the ON position Note Please wait one minute after shut ting off heater to allow the control valve to reset before starting again 13 Make sure heater screen is in pl...

Страница 21: ...aged the slide switch on the receiver can be used to operate the heater Note When batteries are replaced the learning process above must be repeated LEARN REMOTE OFF ON Figure 23 Receiver Slide Switch...

Страница 22: ...he LCD screen will display the set temperature for 3 sec onds then flash the set temperature for 3 seconds then LCD screen will default to display the room temperature To Change The Set Temperature 1...

Страница 23: ...ping follow instructions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame App...

Страница 24: ...irt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner Rep...

Страница 25: ...re Wipe the cabinet to remove dust CARE AND MAINTENANCE Figure 33 Pilot Inlet Air Hole LOGS If you remove logs for cleaning refer to Installing Logs page 17 to properly replace logs Replace log s if b...

Страница 26: ...ass pressure switch See instructions below The entire gas delivery piping including con nections inside the heater should be leak tested by the qualified installer After leak testing the qualified ins...

Страница 27: ...ully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 24 or rep...

Страница 28: ...gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top of page 26 1 Contact a qualified servi...

Страница 29: ...resh air is avail able 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local gas supplier 3 Clean ODS pilot see Care and Maintenance page 24 Ga...

Страница 30: ...www usaprocom com 200346 01A 30 PARTS MODEL FBNSD400RT ZC 9 8 10 12 11 13 15 18 14 6 1 2 3 4 16 7 5 17 PILOT OFF ON RE MO TE OF F ON LEA RN TEMP 19...

Страница 31: ...AAA Battery 1 3 161333 01 AA Battery 4 Not a field replaceable part REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warrant...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...

Отзывы: