background image

                                  3

8.   This heater is designed to be
       smokeless. If logs ever appear to
       smoke, turn off  heater and call a
       qualified service person.
       Note: During initial operation, slight
       smoking could occur due to log
       curing and heater burning manufac
       turing residues.
9.   To prevent the creation of soot,
       follow the instructions in 

Cleaning

       and Maintenance(page 12).

10. Before using furniture polish, wax,
       carpet cleaner, or similar products,
       turn heater off. If heated, the vapors
       from these products may create a
       white powder residue within burner
       box or on adjacent walls or furniture.
11. This heater needs fresh air ventila-
       tion to run properly. This heater has
      an Oxygen Depletion Sensing
      (ODS) safety shutoff system.
      The ODS shuts down the heater if not
       enough fresh air is available. See 

Air for

       Combustion and Ventilation,

 pages 5

       through 6. If heater keeps shutting off,
       see 

Troubleshooting

,  pages 14

       through  15.
12. Do not run heater:

    l 

Where flammable liquids or

                 vapors  are used or stored.

   l 

Under  dusty  conditions.

       13. Do not use this heater to cook

       food or burn paper or other objects.
14. Do not use this heater if any part

              has been under water. lmmedia-
              tely call a qualified service techni-
              cian to  inspect the room heater.

SAFETY  INFORMATION

Continued

QUALIFIED INSTALLING AGENCY

Installation and  replacement  of  gas
piping, gas utilization equipment or ac-
cessories and repair and servicing of
equipment shall be performed only by
a qualified agency. The term 

qualified

agency

  means any  individual,  firm,

corporation, or company that either in
person or through a representative is
engaged in and is responsible for (a)
the installation,testing,or replacement
of  gas  piping  or(b)the  connection,
installation,testing,repair,or servicing
of equipment; that is experienced in
such work; that is familiar with all pre-
cautions required,and that has com-
plied with all the requirement of  the
authorty having jurisdiction.

15.  Turn off and unplug heater and
        let cool before servicing. Only a

qualified service person should
service and repair heater.

16.  Operating heater above
        elevations.

18.  To prevent performance
        problems, do not use propane/
        LP fuel tank of less than 100 lbs.
        capacity.

PRODUCT  FEATURES

SAFETY  PILOT

This heater has a pilot with an
Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot
is a required feature for vent-free
room heaters. The ODS/pilot shuts
off the heater if  there is not enough
fresh air.

MANUAL OVERRIDE CONTROL SYS-
TEM   (FBN(L)400RHA Series)

This  heater  has  two  operation
functions: Remote Control and Manual
Override Control. The Remote Control
has a transmitter, which requires three

AAA

  batteries and electric power

outlet to operate. If no electric power
is available, then you can operate the
heater by manual override.
The ignitor require one 

AAA

  battery.

State of Massachusetts:

 The instal-

lation  must  be made by a licensed
plumber or gas fitter in the Common-
wealth of Massachusetts.
Sellers of unvented propane or natu-
ral gas-fired supplemental room heat-
ers shall provide to each purchaser a
copy of 527 CMR 30 upon sale of the
unit.
In   th e  state  of  Massachusetts,
unvented propane or natural gas-fired
space heaters shall be prohibited in
bedrooms and bathrooms.

In the State of Massachusetts the
gas cock must be a 

T

 handle type.

The  State  of  Massachusetts re-
quires that a flexible appliance con-
nector cannot exceed three feet in
length.

17.  Do not operate heater if any log
        is broken. Do not operate heater
        if any log is chipped (dime-sized
        or larger).of 4,500 feet could
        cause pilot outage.

3

Содержание FBL400RHA Series

Страница 1: ...ting plate This appliance is not convertible for use with other gases CUSTOMER CARE 1 877 866 5989 FBN400RHA Series Remote Control Fireplace FBL400RHA Series Remote Control Fireplace FBN400TYLA Series Thermostat Control Fireplace FBL400TYLA Series Thermostat Control Fireplace Continental Appliance Inc U S Office 5 Musick 4600 Highlands Parkway S E Irvine Suite D E CA 92618 Smyrna GA 30082 WARNING ...

Страница 2: ...and free from combustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rat ing plate This appliance is not con vertible for use with other gases 2 Do not place Propane LP supply tank s inside any structure Locate Propane LP supply tank s outdoors 3 If you smell gas l Shut off gas supply l Do not try to light any ap...

Страница 3: ...he connection installation testing repair or servicing of equipment that is experienced in such work that is familiar with all pre cautions required and that has com plied with all the requirement of the authorty having jurisdiction 15 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater 16 Operating heater above elevations 18 To...

Страница 4: ...tal heat applications the water vapor does not creat a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help insure that water vapor does not become a problem 1 Be sure the heater is a sized properly for the application including ample combustion air and circulation air 2 If high humidity is experienced dehum...

Страница 5: ...ATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume of the space length width height Length Width Height cu ft volume of space Example Space size...

Страница 6: ...ure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr This fresh air would come from an adjoining uncon fined space When ventilating to an adjoining uncon fined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 an...

Страница 7: ... smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 5 through 6 CHECK GAS TYPE Use only the type of gas indicated on th...

Страница 8: ...ure for purpose of input adjustment NG Models 5 to 10 5 W C Gas supplier provide external regulator for natural gas INSTALLATION Continued WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas CAUTION Only use a new black iron or steel pipe Internally tinned copper tubing may be used in certain areas Check you local codes Use pipe of 1 2 diameter ...

Страница 9: ...heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 8 Figure 9 Checking Gas Joints CHECKING GAS CON NECTIONS WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks immediately INSTALLATION Continued 2 Open gas supply tank valve 3 Make su...

Страница 10: ...all the logs exactly as instructed Do not modify logs Only use logs supplied wall heater IMPORTANT Make sure log does not cover any burner ports see Figure 10 Figure 10 Installing Log Set FIG 1 FIG 2 STEP 1 Install log 1 onto the two slots in the rear plate as shown STEP 2 Install log 2 onto the two slots in the left middle plate Install log 3 onto the two slots in the right middle plate STEP 3 In...

Страница 11: ... Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in control knob Never use tools If the the appli ance could not operate don t try to repair it Call a qualified service technician or gas supplier Forced or at tempted re pair may result in a fire or explosion D Do not use this appliance if any part has been under wat...

Страница 12: ...t thirty 30 seconds This will allow air to bleed from the gas system 7 With Control Knob pressed in push ignitor button This will light the pilot If needed keep ignitor button until pilot lights MANUAL OVERRIDE CONTROL SYSTEM OPERATING INSTRUCTIONS 8 Keep Control Knob depressed for ten 10 seconds after lighting pilot If pilot goes out repeat steps 6 7 and 8 9 Turn counterclockwise to ON position D...

Страница 13: ...en disconne ct two wires free to fan 2 Mark or tag each wire removed for its exact reconnection Remove the four screws from the fan when installing reverse the steps above See Figure 20 and Figure 23 Figure 20 Fan WARNING Disconnect power be fore attempting any maintenance or cleaning to reduce the risk of fire elec tric shook or personal injury Turn off heater and let cool before cleaning CLEANIN...

Страница 14: ...k the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 Figure 21 Injector Holder On Outlet Burner Tube Exterior l Use a soft cloth damp...

Страница 15: ...2 25 1 2 Weight lbs Stove 276 276 Shipping 308 308 Mantel A5 Dimensions Inches H W D Heater 44 3 16 46 7 8 16 5 8 44 3 16 46 7 8 16 5 8 Carton 44 7 8 51 20 7 8 44 7 8 51 20 7 8 Weight lbs Stove 265 265 Shipping 295 295 Mantel A Dimensions Inches H W D Heater 45 5 8 50 16 7 8 45 5 8 50 16 7 8 Carton 46 1 2 54 1 2 25 1 2 46 1 2 54 1 2 25 1 2 Weight lbs Stove 276 276 Shipping 308 308 For purposes of ...

Страница 16: ...lot unit Spark at ODS pilot but no ignition 1 Gas supply turned off or equip ment shut off valve closed 2 Air in gas lines when installed 3 Depleted gas supply 4 ODS pilot is clogged 5 Gas regulator setting is not correct 6 Pilot electrude position is not correct 7 Wire is not correct or loosen 8 Gas valve is damage 1 Turn on gas supply or open equip ment shutoff valve 2 Press ON OFF button again ...

Страница 17: ...r name l Your address l Model and serial numbers of your heater l How heater was malfunctioning l Type of gas used propane LP or NG l Purchase date REPLACEMENT PARTS l Warranty card Usually we will ask you to return the defective part to the factory REPLACEMENTPARTS NOTE Use only original replace ment parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARR...

Страница 18: ... ASSEMBLY 1 ND1703X400X4 ODS 1 ND1908X400X4 ODS 1 6 FBB504 ODS INLET TUBE ASSEMBLY 1 1 7 FBB502 INLET TUBE ASSEMBLY 1 1 8 FBB503 OUTLET TUBE ASSEMBLY 1 1 QUALITY KEY NO PART NUMBER DESCRIPTION 5 1 2 3 4 SIT545 T STAT VALVE 1 This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 17 of this manual 18 ...

Страница 19: ... 4 FB 05A5M SIDE PANEL 1 1 5 FB 03A5M BASE 1 1 6 FB 02A5M UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FHL008 02 BAFFLE 1 1 10 FHL021 022 02 SIDE REFLECTOR 2 2 11 FHL007 02B FIREBOX FLOOR 1 1 12 FBB102 LOUVER ASSEMBLY 1 1 13 FHL001 03 BODY BOTTOM COVER 1 1 14 FBB104 SCREEN 1 1 15 FHL015 01T T STAT VALVE BRACKET 1 1 16 PF06 YJLF F FAN 1 1 17 FBB501 BURNER 1 1 18 BL...

Страница 20: ...M SIDE PANEL 1 1 5 FB 03AM BASE 1 1 6 FB 02AM UPPER PANEL 1 1 7 FHL001 01 BODY TOP COVER 1 1 8 FHL001 02 BODY BOARDING 1 1 9 FhL008 02 BAFFLE 1 1 10 FhL021 022 02 SIDE REFLECTOR 1 1 11 FhL007 02B FIREBOX FLOOR 1 1 12 FBB102 LOUVER 1 1 13 FHL001 03 BODY BOTTOM COVER 1 1 14 FBB104 SCREEN 1 1 15 FHL015 01T T STAT VALVE BRACKET 1 1 16 PF06 YJLF F BLOWER 1 1 NB40 140H BURNER ASSEMBLY 1 NB40 032H BURNER...

Страница 21: ...GULATOR 1 NRV82FB 9 REGULATOR 1 ND4703X400 RHN ODS 1 ND4908X400 RHN ODS 1 NB40 032H BURNER ASSEMBLY 1 NB40 140H BURNER ASSEMBLY 1 HL036 02 INJECTOR 1 HL036 01 INJECTOR 1 9 FBB320RH OUTLET TUBE ASSEMBLY 1 1 QUALITY KEYNO PART NUMBER DESCRIPTION 8 5 6 7 This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 17 of th...

Страница 22: ... SIDE PANEL 1 1 6 FhL001 01 BODY TOP COVER 1 1 7 FhL001 02 BODY BOARDING 1 1 8 FhL021 022 02 SIDE REFLECTOR 2 2 9 FhL007 02B FIREBOX FLOOR 1 1 10 FhL001 03 BODY BOTTOM COVER 1 1 11 BL016 01 BLOWER MOUNT PANEL 1 1 12 PF06 YJLF F BLOWER 1 1 13 GCRMA1 CONTROL CABINET ASSEMBLY 1 1 14 GCRTA1 REMOTE 1 1 15 GCRRA1 REMOTE ASSEMBLY 1 1 16 FBB104 SCREEN 1 1 17 FBL015 02HR CONTROL PANEL 1 1 NB40 032H BURNER ...

Страница 23: ......