www.usaprocom.com
200069-01A
22
Key Settings
ON
- Operates unit to on position, manually
operated solenoid ON.
OFF
- Operates unit to off position, manually
operated solenoid OFF.
MODE
- Changes unit from manual mode to
thermo mode.
SET
- Sets temperature in thermo mode.
TEMP
ROOM SET TEMP
1
4
6
2
3
5
Figure 26 - Remote Control
Figure 27 - Remote Control Display
LCD Liquid Crystal Display
1.
DISPLAY
Indicates CURRENT room
temperature.
2.
°F or °C
Indicates degrees Fahrenheit or
Celsius.
3.
FLAME
Indicates burner/valve in operation.
4.
ROOM
Indicates remote is in THERMO
operation.
5.
TEMP
Appears during manual operation.
6.
SET
Appears during time the of setting
the desired temperature in the thermo
operation.
OPERATION
LEARN
REMOTE OFF
ON
Figure 25 - Receiver
Slide Switch
Learn Button
REMOTE CONTROL SYSTEM
Programming the Remote and Receiver
The remote and receiver must be “learned”
to one another.
1. Turn control knob on the heater to the ON
position.
2. Place the slide switch on the receiver in
the remote position (see Figure 25).
3. Use a pen or small screwdriver to gently
press and release the recessed LEARN
button on the face of the receiver. You will
hear a beep.
4. Press the ON button on the remote (see
Figure 26). You will hear a series of beeps.
Your appliance should come on.
Remote Control Operation
This appliance must not be used with glass
doors in the closed position. This can lead
to pilot outages and severe sooting outside
the fireplace.
The transmitter operates on 2 AAA batteries.