Procom FBD32RT Скачать руководство пользователя страница 20

www.usaprocom.com

200069-01A

20

OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a 

fire or  explosion may result caus-

ing property damage, personal 

injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the 

pilot, follow these instructions exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If  the  knob  will  not  push  in  or  turn 

by  hand,  don’t  try  to  repair  it,  call  a 

qualified service technician. Force or 

attempted repair may result in a fire or 

explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

 WARNING: You must oper-

ate this heater with the screen 

in  place.  Make  sure  screen  is 

installed before running heater.
NOTICE: During initial operation 

of new heater, burning logs will 

give off a paper-burning smell. 

Orange flame will also be pres-

ent. Open damper or window to 

vent smell. This will only last a 

few hours.

1.  STOP! Read the safety information above.
2.  Make sure equipment shutoff valve is fully 

open.

3.  Be sure the slide switch on the front of the 

receiver is in the REMOTE position.

4.  Push in the control knob slightly and turn 

clockwise 

 to the OFF position.

5.  Wait five (5) minutes to clear out any gas. 

Then smell for gas around heater and near 

the floor. If you smell gas, STOP! Follow 

"B" in the safety information above. If you 

do not smell gas, go to the next step.

6.  Push in the control knob slightly and turn  

counterclockwise 

  to  the  PILOT 

position. Press in control knob for five (5) 

seconds (see Figure 24).

 

Note: The first time that the heater is oper-

ated after connecting the gas supply,the 

control knob should be pressed for about 

thirty (30) seconds. This will allow air to 

bleed from the gas system. If pilot does not 

stay lit, refer to Troubleshooting, pages 26 

though 29. Also contact a qualified service 

technician or gas supplier for repairs. Until 

repairs are made, light pilot with match.

LIGHTING INSTRUCTIONS

Figure 24 - Control Knob in the OFF 

Position

Ignitor Button

Receiver

Control Knob

Содержание FBD32RT

Страница 1: ...al switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de...

Страница 2: ...irmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property d...

Страница 3: ...egnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP gas are odorless An odor mak...

Страница 4: ...e technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water 10 Turn off and unplug heater and let cool before servicing Only a...

Страница 5: ...ipped to operate on either Propane LP or Natural gas The heater is shipped from the factory ready for connect ing to Propane LP The heater can easily be changed to Natural gas by having your quali fie...

Страница 6: ...umidity atmosphere experienced during cold weather The following steps will help ensure that water vapor does not become a problem 1 Be sure the heater is sized properly for the application including...

Страница 7: ...that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusually t...

Страница 8: ...ional Fuel GasCode ANSIZ223 1 NFPA54 theInternationalFuelGasCode or applicable local codes AIR FOR COMBUSTION AND VENTILATION 30 000 26 000 56 000 Use this work sheet to determine if you have a confin...

Страница 9: ...e of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and on...

Страница 10: ...dles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor Figure 4 Minimum Clearances to Wall and Ceiling IMPORTANT Vent free heaters add moisture to the air Although...

Страница 11: ...der it inoperable The installer shall replace the access cover before completing the installation and operat ing this appliance For changing from propane to natural gas supply 1 Remove 2 screws from c...

Страница 12: ...installing a built in mantel above the fireplace you must follow the clearances shown in Figure 7 NOTICE Surface temperatures of adjacent walls and mantels become hot during operation Walls and mantel...

Страница 13: ...nce to the sides and top of the firebox Combustible materials should never overlap the firebox front Figure 10 Rough Opening for Corner Installation CAUTION Do not operate fireplace without hood in pl...

Страница 14: ...include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 12 page 15 IMPORTANT Install an equi...

Страница 15: ...External Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Conne...

Страница 16: ...ystem by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply...

Страница 17: ...lve see Figure 16 or 17 page 16 Apply a noncorrosive leak detection fluid to all joints Bubbles form ing show a leak 5 Correct all leaks at once INSTALLATION FOR DECORATIVE TRIM 6 Light heater see Lig...

Страница 18: ...in this manual Flames contact ing logs will create soot Each log is marked with a number This number will help you to identify the logs when installing After installing logs add decorative cinders ar...

Страница 19: ...tery life by turning off the receiver when it is not in use For long periods of non operation remove batteries from all components for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control...

Страница 20: ...gas control which has been under water WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperation of new heater bu...

Страница 21: ...lit refer to Troubleshooting pages 26 though 29 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Man...

Страница 22: ...tting the desired temperature in the thermo operation OPERATION LEARN REMOTE OFF ON Figure 25 Receiver Slide Switch Learn Button REMOTE CONTROL SYSTEM Programming the Remote and Receiver The remote an...

Страница 23: ...will be activated The transmitter has ON and OFF manual functions that are activated by pressing either button on the face of the transmitter When a button on the transmitter is pressed the word ON o...

Страница 24: ...26 through 29 WARNING If yellow tipping occurs your heater could pro duce increased levels of carbon monoxide If the burner flame pattern shows yellow tipping follow instructions at bottom of this pa...

Страница 25: ...ary Air Inlet Holes CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube and...

Страница 26: ...ay mix with combustion air and create odors Note All troubleshooting items are listed in order of operation Use a vacuum cleaner pressurized air or a small soft bristled brush to clean A yellow tip on...

Страница 27: ...control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 25 or replace ODS pilot...

Страница 28: ...r for dirt and debris If found clean burner see Care and Maintenance page 25 2 Replace gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and...

Страница 29: ...in OFF position 1 Gas leak See Warning Statement at top of page 26 2 Control valve is defective 1 Locate and correct all leaks see Checking Gas Connec tions page 16 2 Contact customer service Moisture...

Страница 30: ...www usaprocom com 200069 01A 30 PARTS MODEL FBD32RT RE MO TE OF F ON LE AR N TEMP 18 20 24 22 25 19 21 26 23 11 12 14 16 17 15 15 8 4 13 5 6 7 2 3 9 10 1...

Страница 31: ...01 Ignitor 1 9 RV83FI 4 9 Regulator 1 10 PF120820 Regulator Plug 2 11 RG04 1M Receiver 1 12 RG04 1T Remote Control 1 13 FB32D201 Hood 1 14 FB32D104 Upper Decorative Trim 1 15 FB32D121 Left Right Deco...

Страница 32: ...ller in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and...

Отзывы: