Procom FBD32RT Скачать руководство пользователя страница 1

VENT-FREE GAS

FIREPLACE INSERT

OWNER’S OPERATION AND 

INSTALLATION MANUAL

MODEL FBD32RT

PFS

®

US

 

WARNING: If the information in this manual is not 

followed exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life.
—  Do not store or use gasoline or other  flammable va-

pors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

 

WARNING: This appliance is equipped for Natural and 

Propane gas. Field conversion is not permitted other than 

between natural or propane gases.

Questions, problems, missing parts?

 Before returning to your retailer, call 

our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST, 

Monday through Friday or email

 [email protected]

Содержание FBD32RT

Страница 1: ...al switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de...

Страница 2: ...irmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property d...

Страница 3: ...egnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP gas are odorless An odor mak...

Страница 4: ...e technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water 10 Turn off and unplug heater and let cool before servicing Only a...

Страница 5: ...ipped to operate on either Propane LP or Natural gas The heater is shipped from the factory ready for connect ing to Propane LP The heater can easily be changed to Natural gas by having your quali fie...

Страница 6: ...umidity atmosphere experienced during cold weather The following steps will help ensure that water vapor does not become a problem 1 Be sure the heater is sized properly for the application including...

Страница 7: ...that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusually t...

Страница 8: ...ional Fuel GasCode ANSIZ223 1 NFPA54 theInternationalFuelGasCode or applicable local codes AIR FOR COMBUSTION AND VENTILATION 30 000 26 000 56 000 Use this work sheet to determine if you have a confin...

Страница 9: ...e of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling and on...

Страница 10: ...dles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor Figure 4 Minimum Clearances to Wall and Ceiling IMPORTANT Vent free heaters add moisture to the air Although...

Страница 11: ...der it inoperable The installer shall replace the access cover before completing the installation and operat ing this appliance For changing from propane to natural gas supply 1 Remove 2 screws from c...

Страница 12: ...installing a built in mantel above the fireplace you must follow the clearances shown in Figure 7 NOTICE Surface temperatures of adjacent walls and mantels become hot during operation Walls and mantel...

Страница 13: ...nce to the sides and top of the firebox Combustible materials should never overlap the firebox front Figure 10 Rough Opening for Corner Installation CAUTION Do not operate fireplace without hood in pl...

Страница 14: ...include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 12 page 15 IMPORTANT Install an equi...

Страница 15: ...External Regulator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Conne...

Страница 16: ...ystem by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply...

Страница 17: ...lve see Figure 16 or 17 page 16 Apply a noncorrosive leak detection fluid to all joints Bubbles form ing show a leak 5 Correct all leaks at once INSTALLATION FOR DECORATIVE TRIM 6 Light heater see Lig...

Страница 18: ...in this manual Flames contact ing logs will create soot Each log is marked with a number This number will help you to identify the logs when installing After installing logs add decorative cinders ar...

Страница 19: ...tery life by turning off the receiver when it is not in use For long periods of non operation remove batteries from all components for safety Component Type of Battery Qty Ignitor AAA 1 Remote Control...

Страница 20: ...gas control which has been under water WARNING You must oper ate this heater with the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperation of new heater bu...

Страница 21: ...lit refer to Troubleshooting pages 26 though 29 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Man...

Страница 22: ...tting the desired temperature in the thermo operation OPERATION LEARN REMOTE OFF ON Figure 25 Receiver Slide Switch Learn Button REMOTE CONTROL SYSTEM Programming the Remote and Receiver The remote an...

Страница 23: ...will be activated The transmitter has ON and OFF manual functions that are activated by pressing either button on the face of the transmitter When a button on the transmitter is pressed the word ON o...

Страница 24: ...26 through 29 WARNING If yellow tipping occurs your heater could pro duce increased levels of carbon monoxide If the burner flame pattern shows yellow tipping follow instructions at bottom of this pa...

Страница 25: ...ary Air Inlet Holes CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube and...

Страница 26: ...ay mix with combustion air and create odors Note All troubleshooting items are listed in order of operation Use a vacuum cleaner pressurized air or a small soft bristled brush to clean A yellow tip on...

Страница 27: ...control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 25 or replace ODS pilot...

Страница 28: ...r for dirt and debris If found clean burner see Care and Maintenance page 25 2 Replace gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and...

Страница 29: ...in OFF position 1 Gas leak See Warning Statement at top of page 26 2 Control valve is defective 1 Locate and correct all leaks see Checking Gas Connec tions page 16 2 Contact customer service Moisture...

Страница 30: ...www usaprocom com 200069 01A 30 PARTS MODEL FBD32RT RE MO TE OF F ON LE AR N TEMP 18 20 24 22 25 19 21 26 23 11 12 14 16 17 15 15 8 4 13 5 6 7 2 3 9 10 1...

Страница 31: ...01 Ignitor 1 9 RV83FI 4 9 Regulator 1 10 PF120820 Regulator Plug 2 11 RG04 1M Receiver 1 12 RG04 1T Remote Control 1 13 FB32D201 Hood 1 14 FB32D104 Upper Decorative Trim 1 15 FB32D121 Left Right Deco...

Страница 32: ...ller in accordance with all local codes and instructions furnished with the unit WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and...

Отзывы: