Procom EL250TYLA-B Скачать руководство пользователя страница 22

  2 2

21

      INSTALLING BLOWER  ACCESSORY

BLOWER ACCESSORY MODEL NFHTX186

1.From back of heater remove the knock

   out center panel with two brackets at the

   four sides with a Philips head screwdriver

   (see Figure 1).

2. Attach the two brackets to blower hous

    ing using four white screws provided in

    blower kit (2 for each bracket) (see Fig

    ure 2). Tighten screws securely. Then

    guide the green grounding means wire

    and downlead of motor through the panel

    capped hole.

3. Guide the four strand wire of downlead

    through the panel hole. Connect the two

    yellow leads and the temperature control

   switch on the temperature controlled

   bracket togther. Secure the temperature

   controlled bracket on the reflective panel

   of firebox using two self-tapping screws

   (See Figure 3-A).

4. Using the previously removed screws,

    mount blower assembly to stove by reat

    taching the knock-out center panel to rear

   panel. Draw the four strand cable back-

ward so as to expose the three black,

green, white lines on the four strand

cable at the back of rear panel.Be sure

not to drop the temperature controlled

wire off the reflective panel. Connect the

green grounding means wire and four

strand cable together.Connect the two

black motor downleads respectively

and the remaining two black and white

wires together by the same means (see

Figure 3-A). 

(Note: the three

 

wires

must be connected at the rear panel)

   5. Using the thread that previously bond

the electrical wire to collect and pack

the outside connection wire of the

cable.

   6.  A . EN(L)250TYLA model Guide the

        operating control housing through the

        bottom hole of rear  panel, and place

         it on the mounting bracket in the door.

       Mounting operating control housing to

      the mounting bracket with two screw.

      (see figure 4)

     B.  EN(L)250TYLBmodel Insert  opera-

         tion control housing at the back bot-

        tom of stove.Use two black screws

       provided in blower kit. Mount blower

      operation control housing to the

       bracket at the bottom of stove (see Fig

       ure 5).

7.

Check to make sure that the power

cord is c ompletely clear of blower

wheel and there are no foreign objects

in blower wheel.

8. Use screws provided in blower

    kit to as semble the plate which

    assembled with strain relief

   bushing and power cord on the

   knock-out center panel.

9.Peel off the backing paper and

   stick the supplied wiring diagram

  decal on the back panel as show

  in Figure 4-B.

ACCESSORY 

NFHTX186

Tools  required: Philips screwdriver

NOTICE: Shut off gas heater dur-

i n g   t h e   f o l l o w i n g   b l o w e r

installation.

Figure 1  Removing Knock-out Panel

Figure 2  Attaching Brackets To Blower

P

10.Plug power cord into a conve

    nient 3-prong grounded wall

    recep tacle near the stove.

WARNING

:

 1. ELECTRICAL

GROUNDING INSTRUCTIONS:

This appliance is equipped

with a three-prong (grounding)

pl ug   fo r  you r  p ro tec ti on

agains t shock hazard and

should be plugged directly into

a properly grounded three-

prong receptacle.

2. Do not let the wires touch

the reflective panel of the

firebox.

 

Feed the wires of the

motor and green wire through

the hole of the knock-out

panel.

11. Using Auto/O/man switch. Turn

b lo wer   o n   an d   c h ec k   f o r

operation. Turn on Auto/O/Man

switch to the desired position.

Man position will remain con-

stantly on. Auto position will be

controlled by the thermostat on

fan blower unit. To stop the

operation, turn unit switch to the

O position.

12. A l l  r e m ain in g   p a r t s   f r o m

blower kit  may be discarded.

Содержание EL250TYLA-B

Страница 1: ...f sale not for pur pose of resale from the manufacturer Safety Information Warnings 2 Air for Combustion and Ventilation 4 Installation 6 Operating heater 9 Cleaning Maintenance 10 Trouble Shooting 11...

Страница 2: ...d in a bedroom or bathroom erating heater 5 Do not use this heater as a wood burning heater Use only the logs pro vided with the heater 6 Do not add extra logs or ornaments such as pine cones vermicul...

Страница 3: ...ct of gas combustion An unvented room heater productes approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as supplemental h...

Страница 4: ...ining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining...

Страница 5: ...Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr This fresh air would come from an adjoining uncon fined space Wh...

Страница 6: ...vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may dis color walls IMPORTANT Vent...

Страница 7: ...1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur Installation must include an equip ment shutoff valve union and plugged 1 8 NPT tap...

Страница 8: ...xture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for lea...

Страница 9: ...sition 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on page 2 If you don t smell gas go to the next s...

Страница 10: ...e To Turn Off Gas to Appliance page 9 see Troubleshooting pages 11 through 12 CLEANING AND MAINTENANCE WARNING Turn off heater and let cool before cleaning CAUTION You must keep c o n t r o l a r ea s...

Страница 11: ...may become blocked by debris or rust with no flame present If so turn off heater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot TROUBLE SHOOTING Not...

Страница 12: ...1 C l e a n b u r n e r s e e C l e a n i n g and Maintenance page 10 or replace burner orifice 2 Contact local propane LP gas company 3 Replace burner orifice 4 Reconnect leads Delayed ignition burne...

Страница 13: ...mensions Inches H W D Stove 38 3 16 26 3 8 14 1 8 Carton 37 29 5 16 15 5 16 41 3 8 x29 5 16 x17 3 8 Weight lbs Stove 73 78 73 78 Shipping 89 94 89 94 For purposes of input adjustment The carton dimens...

Страница 14: ...e will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product Call PRO COM at 877 886 5989 for referral information When calling PRO CO...

Страница 15: ...1 5 14 ILLUSTRATED PARTS BREAKDOWN EL250TYLA B EL250TYLA W EL250TYLB O EL250TYLA C EL250TYLB DO EN250TYLA B EN250TYLA W EN250TYLB O EN250TYLA C EN250TYLB DO...

Страница 16: ...e parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 14 of this manual EL250TYLA B EL250TYLA W EL250TYLB O EL250TYLA C EL250TYLB DO EN250TYLA...

Страница 17: ...1 7 16 ILLUSTRATED PARTS BREAKDOWN EL250TYLA B EL250TYLA W EN250TYLA B EN250TYLA W...

Страница 18: ...1 8 12 17 PARTS LIST EL250TYLA B EL250TYLA W EN250TYLA B EN250TYLA W...

Страница 19: ...1 9 18 ILLUSTRATED PARTS BREAKDOWN EL250TYLB O EN250TYLB O EN250TYLB C EL250TYLB C EN250TYLB DO EL250TYLB DO...

Страница 20: ...2 0 19 PARTS LIST EL250TYLB O EN250TYLB O EN250TYLB C EL250TYLB C EN250TYLB DO EL250TYLB DO...

Страница 21: ...g logs Fasten decorating logs 1 2 3 onto the correspondent angle iron Figure 4 Insert the pinhole on the upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roo...

Страница 22: ...ear panel and place it on the mounting bracket in the door Mounting operating control housing to the mounting bracket with two screw see figure 4 B EN L 250TYLBmodel Insert opera tion control housing...

Страница 23: ...Power Cord WiringDiagram Decal INSTALLING BLOWER ACCESSORY BLOWER ACCESSORY MODEL NFHTX186 Figure 3 A Routing Power Cord Figure 5 Mounting Control Housing MODEL EL N 250TYLB Figure 4 Mounting Control...

Отзывы: