1 1
Clean the pilot assembly also . A
y e l l o w t i p o n t h e p i lo t f l a m e
indicates dust and dirt in the pilot
assembly. There is a small pilot air
inlet hole about two inc hes from
where the pilot flame comes out of
the pilot assembly (see Figure 18).
W ith the unit off, lightly blow air
through the air inlet hole. You may
blow through a drinking straw if
c o mpressed air is not available.
Figure 18-Pilot Air Inlet Hole
REMEDY
CLEANING AND MAINTENANCE
Continued
CABINET
Air Passageways
Use a vacuum cleaner or pressur-
ized
air to clean.
EXTERIOR
Use a soft cloth dampened with a
mild soap and water mixture. W ipe
t h e c a b i n et t o r em o v e d u s t .
LOGS
If you remove logs for cleaning,
r ef er t o
I n s t a l l in g L og s
, pag e
19, to properly replace logs.
Replace log(s) if broken or chipped
(dime-sized or larger).
MAIN BURNER
Periodically inspect all burner flame
holes with the healer runn ing. All
slotted burner flame holes should
be open with yellow flame present.
All round burner flame holes should
be op en with a small blue flame
present. Some burner flame holes
may become blocked by debris or
rust, with no flame present. If so,
turn off heater and let cool. Either
remove blockage or replace burner.
Blocked burner flame ho les will
create soot.
TROUBLE SHOOTING
Note
:
All troubleshooting items
are listed in order of operation.
WARNING:
Turn off heater and
let cool before servicing. Only a
qualified service person should
service and repair heater.
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.
W hen ignitor button is
pressed, there is a spark at
ODS/pilot but no ignition.
OBSERVED PROBLEM
POSSIBLE CAUSE
1. Gas supply turned off or equipment
shutoff valve closed.
2. Control knob not in PILOT position.
3. Control knob not pressed in while in
PILOT position.
4. Air in gas lines when installed.
5. Depleted gas supply.
6. ODS/pilot is clogged.
7. Gas regulator setting is incorrect.
1. Turn on gas sup ply or o p en
equipment shutoff valve.
2. Turn control knob to PILOT position.
3. Press in control knob while in PILOT
position.
4. Continue holding down co ntro l
knob. Repeat igniting operation
until air is removed.
5. Contact local propane/LP gas
company.
6. Clean ODS/pilot (see Cleaning
and Maintenance,page 10 ) or replace
ODS/pilot assembly.
7.
Replace gas control.
10
Содержание EL250TYLA-B
Страница 17: ...1 7 16 ILLUSTRATED PARTS BREAKDOWN EL250TYLA B EL250TYLA W EN250TYLA B EN250TYLA W...
Страница 18: ...1 8 12 17 PARTS LIST EL250TYLA B EL250TYLA W EN250TYLA B EN250TYLA W...
Страница 19: ...1 9 18 ILLUSTRATED PARTS BREAKDOWN EL250TYLB O EN250TYLB O EN250TYLB C EL250TYLB C EN250TYLB DO EL250TYLB DO...
Страница 20: ...2 0 19 PARTS LIST EL250TYLB O EN250TYLB O EN250TYLB C EL250TYLB C EN250TYLB DO EL250TYLB DO...