PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is
a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough
fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic piezo control system. This system requires AAA batteries (provided).
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner on and off to maintain a desired room temperature. See page 15
DUAL FUEL CAPABLE
Your heater is equipped to operate on either Propane or Natural gas. The heater is shipped from the factory
ready for Propane connection. The heater can easily be changed to Natural gas by having your qualified
installer follow the instructions on page 12 and the markings on the heater.
State of Massachusetts:
The installation must be made by a licensed plumber or gas fitter in the
Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall be prohibited in
bedrooms and bathrooms.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest
edition of the National Fuel Gas Code, ANSI Z 223.1/ NFPA 54*.
*Available from:
American National Standards lnstitute, lnc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, lnc.
1 Batterymarch Park
Quincy, MA 02269
This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of
vent-free heaters.
5
In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts
requires that a flexible appliance connector cannot exceed three feet in length.
Содержание EDP200T-C