background image

33

Operations

Water Pumping And Heat Transfer System

Cold water enters the console through the water inlet. 
When the water box is full the valve will automatically 
shut off.

Water then flows from the water box, through the 
strainer, into the solution pump. The water is pumped to 
the pressure regulator manifold, which provides and 
maintains the desired pressure setting.

A certain amount of water is by-passed from the 
pressure regulator due to over pumping capacity of the 
solution pump.  Water that is not called for in the 
cleaning process is channeled through a copper heater 
core in the front of the heat exchanger box. This bypass 
water circulates several times through the heater core, 
pre-warming the water.

The next stage of heating and water flow is to the 
helicoil, when water is called for in the cleaning process 
it flows to the helicoil under pressure.  Heat from the 
engine coolant is exchanged to the cleaning water 
through a series of coiled copper tubing. This allows the 
engine coolant to travel in a counter rotating direction to 
the cleaning water during the exchange process 
creating a very efficient transfer of heat out of the 
engine and into the cleaning water.

 

The third stage of plumbing and heat exchange takes 
place in the 2nd and 3rd heater cores located in the 
heat exchanger box.   This is the hottest point of the 
gases coming from the vac pump and the engine 
exhaust. These hot gases are forced through the 
heater cores creating the third stage of heat transfer to 
the cleaning water.

Finally, the hot cleaning water passes to the solution 
outlet manifold where cleaning chemicals are injected 
from the chemical pulse pump.  This manifold serves as 
a temperature sensing point and a connecting point for 
the solution hoses.  Also a check valve is located in this 
outlet manifold prohibiting chemicals from backing up 
into the system.

The cleaning solution then passes through high 
pressure solution hoses and is distributed by the 
cleaning tool to a surface that is being cleaned, 
completing the water pumping and heating cycle of the 
cleaning unit.

In the optional high-pressure model, water is routed 
directly to the high-pressure outlet through the 
regulator when the solution pressure lever is in the up 
position.

86411100 Manual Operators - Everest E-Idle Prochem

Содержание EVEREST 408

Страница 1: ...146 0 EVEREST 408 HIGH PRESSURE 1 001 151 0 EVEREST 408 LOW PRESSURE 1 001 152 0 EVEREST 650 E IDLE HIGH PRESSURE 1 001 158 0 EVEREST 650 E IDLE LOW PRESSURE 1 001 159 0 EVEREST 408 E IDLE HIGH PRESS...

Страница 2: ......

Страница 3: ...choice of procedure the skill of the mechanic and the tools or parts available Before attempting any repair make certain that you are thoroughly familiar with this equipment and are equipped with the...

Страница 4: ...rements 22 Fuel Requirements 23 Engine Oil Requirements 23 Chemical Requirements 23 Electronic Fuel Injection System 23 Emission Control Information 24 Date Stamp Location 24 Fuel Pump And Filter 24 T...

Страница 5: ...e Water Box 50 Pre filter Strainer 50 Waste Tank Vacuum Inlet Filter 50 Solution Screen Outlet 50 Temperature Balance Orifice 50 Check Valve Outlet 51 Chemical Pump 51 Pressure Regulator 51 Vacuum Hos...

Страница 6: ...ng items unless otherwise specified and any optional accessories which were ordered NOTE Do not modify unit without written permission from manufacturer Equipment List 1 Console 2 Waste tank 3 Fuel Pu...

Страница 7: ...product damage personal injury or severe injury resulting in death The INSTALLATION section contains information on how to properly install the unit in your vehicle The OPERATIONS section is to famil...

Страница 8: ...gh speed moving parts such as belts and pulleys should be avoided while this unit is running Severe injury damage or fatality may result DO NOT service this unit while it is running The high speed mec...

Страница 9: ...ns We require high back seats on all vehicles in which units are to be installed for head and neck protection We recommend using a metal partition between the seats and equipment DO NOT operate this u...

Страница 10: ...roies et les poulies devraient tre vit es durant le fonctionnement de cet appareil Cela pourrait causer des blessures graves des dommages ou la mort NE PAS r parer cet appareil pendant qu il est en ma...

Страница 11: ...es baquets dans tous les v hicules dans lesquels des appareils sont install s pour une meilleure protection de la t te et du cou Nous recommandons d utiliser une cloison m tallique entre les si ges et...

Страница 12: ...hine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentially dangerous conditions to the operato...

Страница 13: ...d une d t rioration de la machine Ne pas utiliser la machine si celle ci ne fonctionne pas correctement Lire soigneusement les informations ci dessous signalant certains dangers potentiels pour l op r...

Страница 14: ...labels NOTE If at any time the labels become illegible promptly replace them REMARQUE Les sch mas ci dessous indiquent l emplacement des plaques de s curit Si les plaques deviennent illisibles les re...

Страница 15: ...13 86411100 Manual Operators Everest E Idle Prochem Notes...

Страница 16: ...ing in a trailer make certain that trailer is rated for the total weight of UNIT AND TRAILER Electric or hydraulic brakes should be provided and a strict compliance with any State and Federal vehicle...

Страница 17: ...illustrations for waste tank and console dimensions Bolting Down Unit And Waste Tank When positioning waste tank with respect to console hook up the vacuum hose from blower to waste tank This will ens...

Страница 18: ...16 Installation Layout with 100 Gallon Waste Tank 2 81 2 3 43 4 3 111 8 4 31 8 4 41 8 1 15 8 105 8 5 5 16 5 61 2 3 2 1 16 4 513 16 11 2 1 91 2 65 8 86411100 Manual Operators Everest E Idle Prochem...

Страница 19: ...compo nents near the catalytic converter exhaust or any areas of high temperature Avoid any contact with moving parts areas of high temperature brake lines fuel lines muffler catalytic converter or s...

Страница 20: ...the vehicle floor at the installation point chosen for the bulkhead 3 Install the 1 8 NPT bulkhead adapter by inserting the adapter and tightening the nut on the opposite side of the van floor 4 Insta...

Страница 21: ...ing supplied hose clamps 3 Install 1 1 8P x 5 16 push on hosebarb fitting on to the bulkhead adapter 4 Measure and cut a length of 5 16 fuel hose and connect between the outlet side of the electronic...

Страница 22: ...entil s Garder la batterie l cart des tincelles de la flamme nue et de toute autre source d inflammation en tout temps Garder les batteries hors de la port e des enfants Enlever tous les bijoux au mom...

Страница 23: ...pressure Optional 3000 PSI maximum Vacuum relief valve 13 Hg Waste tank capacity 100 gallons Console weight Model 408 HP 408 1065 lbs Console weight Model 650 HP 650 1150 lbs Console weight with waste...

Страница 24: ...are operating this unit in an area where the unit will be using water in which the hardness exceeds 3 1 2 grains we highly recommend a suitable water softener be installed If using a water softener i...

Страница 25: ...and 20W 50 Higher viscosity oils should be used in high temperature operating conditions and lower viscosity oils should be used in cooler tempera ture operating conditions Chemical Requirements This...

Страница 26: ...back of the engine block approximately where indi cated Fuel Pump And Filter Your Everest console was shipped to the dealer with a specific fuel pump and fuel filter Ensure that ONLY these items are...

Страница 27: ...matically after 20 start run stop cycles if the fault has not been detected DTC Pcode Fault Description CAN SPN CAN FMI Turnson MIL MIL Flash Code Leader Trailer Code 111 1 P0016 CRANK or CAM could no...

Страница 28: ...2 41 P0420 Catalyst inactive on gasoline 520211 10 Yes 421 42 P0524 Engine Oil Pressure Too Low 100 1 Yes 524 43 P0562 Battery Voltage Low 168 17 Yes 562 44 P0563 Battery Voltage High 168 15 Yes 563 4...

Страница 29: ...P0031 Yes 714 97 P1615 Microprocessor failure A D P0629 P0031 Yes 715 98 P1616 Microprocessor failure Interrupt P0629 P0031 Yes 716 99 P1644 MIL control short to GND P1213 P0004 No 644 100 P1645 MIL...

Страница 30: ...CONTROL PANEL PANEL LOWER CONTROL FILTER BOX 12 11 10 9 8 7 6 5 4 3 2 1 Operation High Pressure closed prior to valve must be pump isolation pump Chemical damage chemical system will High pressure 13...

Страница 31: ...igh Pressure Solution Outlet Option The high pressure solution outlet is the connecting point for the high pressure washing hose This outlet is a quick disconnect that allows the pressure washing hose...

Страница 32: ...30 Operations Upper Control Panel 15 20 3 10b 1 2 4 18 5 17 6 16 15 14 7 13 8 12 11 10a 9 86411100 Manual Operators Everest E Idle Prochem...

Страница 33: ...ll continue to run To turn power off rotate key counter clockwise to stop position engine will then stop 8 Circuit Breakers These serve to protect the circuits from electrical spike and over loads and...

Страница 34: ...nergize the magnetic clutch to turn the solution pump on or off Turn clockwise for activating the pump and counter clockwise for deacti vating the pump Filter Box 1 Vacuum Inlets The vacuum inlets ser...

Страница 35: ...the cleaning water during the exchange process creating a very efficient transfer of heat out of the engine and into the cleaning water The third stage of plumbing and heat exchange takes place in the...

Страница 36: ...34 Operations 86411100 Manual Operators Everest E Idle Prochem...

Страница 37: ...35 Operations 86411100 Manual Operators Everest E Idle Prochem...

Страница 38: ...hemical can be directed to the metering valve The metering valve controls the amount of chemical that enters the solution outlet manifold The manifold assembly s check valve will not allow the chemica...

Страница 39: ...s of changes in direction and velocity The air is then filtered and rushes into the vacuum pump The vacuum pump compresses and heats the incoming air The hot discharged air is forced down stream into...

Страница 40: ...se to the water supply faucet NOTE Never use your waste pump outlet hose as a water inlet hose Use only clean hoses for water inlet 2 Turn the water supply faucet on The water will fill the water box...

Страница 41: ...ete NEVER dispose of waste in storm drains water ways or on ground areas Always dispose of waste in accordance with Local State and Federal laws NE JAMAIS liminer les r sidus dans les collec teurs d e...

Страница 42: ...he high pressure system NEVER use your low pressure system hoses with the high pressure system Prochem offers a special high pressure hose rated for pressure washer activities Only use Prochem approve...

Страница 43: ...eaning operations in that no water or solution is required An automatic waste pump out is highly recommended for all de flooding operations due to the large amount of water removal often required 1 Mo...

Страница 44: ...hment P N 86260700 to the bottom solution outlet connection and the water inlet connection Turn the solution pump switch ON Allow the unit to run for approximately 3 minutes with the winterizing loop...

Страница 45: ...flow into the other side of the system High Pressure Optional Close ball valve between chemical pump and solution pump Move pressure system valve to high pressure position Open the tool valve and drai...

Страница 46: ...perature Balance Orifice Weekly Remove clean and check screen Battery Weekly Check for proper fluid level Fill with distilled water only Solution Outlet Screen Bi Weekly Inspect and remove any debris...

Страница 47: ...rque values Re torque if required Drive Pulley 500 hrs Inspect clean and check for pulley groove wear Drive Pulley 500 hrs Check pulley alignment Drive Belts 500 hrs Replace Drive Belts 500 hrs Check...

Страница 48: ...o keep your chemical system functioning properly follow the chemical pump and solution outlet maintenance in the Maintenance Schedule in this manual Refer any additional questions to your dealer Heat...

Страница 49: ...ican Petroleum Institute service class SH The recommended SAE viscosity grades are 10W 40 or 15W 40 for regular oil Recommended viscosity grades for synthetic oil are 10W 30 10W 40 15W 50 and 20W 50 N...

Страница 50: ...the unit at least 1 minute to remove any moisture from the vacuum pump 3 Fill the lubrication cup with water displacing lubri cant for 5 seconds while the unit is running and the vacuum inlets are se...

Страница 51: ...Check for pulley groove wear clean belts and pulley grooves check for worn belts proper belt tension and pulley alignment after the first 25 hours and then again at 100 hours Check for belt ride in th...

Страница 52: ...eplace if needed See the Illus trated Parts Listing for a parts break down Pre filter Strainer The strainer basket located inside the pre filter box should be removed and cleaned whenever it is full o...

Страница 53: ...rated at 4000 PSI NE PAS tenter de r parer les flexibles solution haute pression Tenter de r parer des flexibles solution haute pression pourrait causer des br lures et des blessures graves All high...

Страница 54: ...f the check valve poppet damaged spring or o rings will cause poor operation of the chemical system 6 Lubricate the o rings with o ring lubricant and rein stall Chemical Pump The only repairs that the...

Страница 55: ...h your unit running tool valve open and solution pump on check the pressure gauge We recommend setting the pressure regulator so that the pressure gauge reads 450 PSI with the tool valve closed When t...

Страница 56: ...fill a gallon container about every 17 seconds at high speed Examine the check valves plunger cups and cylinder head on the solution pump Repair whenever required refer to the solution pump service ma...

Страница 57: ...clog the strainer If damaged replace Suction leak in the inlet tube leading into the chemical pump Inspect inlet tube and flow meter for damage and replace if required Chemical pump check valve s is c...

Страница 58: ...e starter motor If necessary replace Vacuum pump seized Refer to Gardner Denver Service Repair Manual or dealer Starter turns over engine but will not start Waste tank is full Empty the waste tank Def...

Страница 59: ...et Adjust lever Automatic waste pump is malfunctioning or not operating normally NOTE When replacing the pump or float switch on internal in tank pumpout use new electrical connectors and heat shrink...