M-43-25
LUF-Series Lufran Manual
Revision - Date 03-01-04-18 Standard outlet, Standard Interface
Engineering Information (Continued):
Facility Requirements:
Before installing the Lufran fluoropolymer inline water heater confirm the facility requirements listed
below.
Space Requirements:
The Lufran fluoropolymer inline water heater is constructed in a freestanding enclosure. This cabinet
includes the common framework for the heating column(s) as well as the electrical components. No
additional support is required.
The dimensions of the specific model are based upon the unit wattage. The cabinet assembly requires
ventilation. Locate equipment so that ventilation fans on the top and bottom of the enclosure and louvers
on the sides are not obstructed. The ventilation fan exhausts through these openings, preventing
overheating of the unit. Be sure to provide adequate clearance for normal operation and maintenance of
this heater.
Typical Cabinet Dimensions
Heater Wattage
(kW)
Number of Heating
Columns
Width
Depth
Height
24-78
1
508mm (20-in)
769mm (30.25-in) 2123mm (83.57-in)
105-156
2
712mm (28-in)
769mm (30.25-in) 2123mm (83.57-in)
195-312
3-4
1220mm (48-in)
769mm (30.25-in) 2123mm (83.57-in)
Figure 3: Clearance Dimensions (24-78kW units shown)