Operating Instructions

Swiss Precision since 1954

Design Patent Pending

Содержание PunditPL-200PE

Страница 1: ...Made in Switzerland 60 Years of Innovation Operating Instructions Swiss Precision since 1954 Design Patent Pending ...

Страница 2: ...sducer D Pundit Pulse Echo Cable E Pundit Pulse Echo Contact Tester F Power Supply G USB Cable H DVD with Software I Documentation J Carrying Strap K Calibrated Tape Part of the Pundit Pulse Echo Trans ducer package Part No 327 40 130 A F J G B H I Scope of Delivery D E C K ...

Страница 3: ...10 10 10 10 10 10 10 10 10 10 23 2 3 10 3 2 23 3 2015 Proceq SA Overview Pundit PL 200PE 1 1 2 3 4 5 6 7 8 9 10 2 ...

Страница 4: ...0 3 5 Measurement Modes 11 3 6 Measuring with Pundit PL 200PE 15 4 Explorer 16 4 1 Analysis of B Scans 17 5 Ordering Information 17 5 1 Units 17 5 2 Transducers 17 5 3 Accessories 18 6 Maintenance and Support 18 6 1 Maintenance 18 6 2 Support Concept 18 6 3 Warranty Information 18 6 4 Disposal 18 7 PL Link Software 19 7 1 Starting PL Link 19 7 2 Viewing the Data 19 7 3 Adjusting the Settings 21 7 ...

Страница 5: ...nents Serious damage resulting from the effects of foreign bodies accidents vandalism and force majeure All information contained in this documentation is presented in good faith and believed to be correct Proceq SA makes no warranties and excludes all liability as to the completeness and or accuracy of the information 1 3 Safety Instructions The equipment is not allowed to be operated by children...

Страница 6: ... Battery Lithium Polymer 3 6 V 14 0 Ah Mains 9 V 15 V 2 0 A Weight About 1525 g incl Battery Dimensions 250 x 162 x 62 mm Operating Temperature 0 C 30 C Charging running instrument 0 C 40 C Charging instrument is off 10 C 50 C Non charging Humidity 95 RH non condensing IP Classification IP54 Standards and Directives CE certification Battery Lifetime 8h in standard operating mode Pollution Degree 2...

Страница 7: ...e charging and turns to green when fully charged The other LEDs are application specific NOTE Only use the power supply provided A complete charge requires 9h Instrument not operating Charging time is much longer if the instrument is in use An optional quick charger Part No 327 01 053 can be used to charge a spare battery outside of the instrument In this case it takes 4h for a complete charge Ene...

Страница 8: ... on an item to adjust it Transducer Connected Transducer If a Pulse Echo Transducer is connected this will be recognized automatically Test Transducer Each individual dry contact transducer can be tested for correct func tionality The graphic on the right hand side of the screen indicates which trans ducer pair is to be tested blue highlight Press the Pulse Echo Contact Tester E onto the transduce...

Страница 9: ...may also be inverted by setting the maximum value lower than the minimum B Scan Distance between measurements Set the spacing between measurements For good resolution images a spacing of 1 cm is recommended For a quicker initial scan a coarser spacing may be used e g 2 5 cm corresponding to the spacing markers on the Pulse Echo Transducer When searching for larger objects such as delaminations or ...

Страница 10: ...press return Saved measure ments will be stored with this file name If several measurements are made under the same file name a suffix increments after each measure ment 2 Measurement mode Select the type of measurement to be carried out see section 3 5 Measurement Modes 3 The top right hand corner of the display shows the current trans ducer selected current time and the battery status 4 Gain Adj...

Страница 11: ...tively it is possible to estimate the pulse velocity directly on surface of the test object Tap on this button and press the transducer against the surface to make a measurement A number of measurements can be made and an average value is calculated Tap to apply the pulse velocity set ting Pulse velocity may be subsequently adjusted on saved files in the Explorer or in PL Link NOTE Typical shear w...

Страница 12: ... the tunnel shell and the rock surface Setting the result to distance allows areas of reduced thickness to be easily identified The cursor position indi cates the position of the next measurement Ensure that this aligns with a grid drawn out on the test structure You may drag the cursor to the position on the grid where you wish to start measuring Arrows indicated the direc tion of proceeding with...

Страница 13: ...to save the current B Scan Press this icon or the right button on the transducer to continue the current B Scan Use this icon to delete the last measurement made Press the to save the current series and reset the in strument for a new series The green cursor cross hairs may be moved to any point on the B Scan simply by dragging The actually cursor position is displayed on the axes The current A Sc...

Страница 14: ...Scan mode it is located in the A Scan window at the right side of the screen Press and drag on either end of the gate to adjust the range In order to find a suitable range it is advisable to first carry out an auto matic pulse velocity estimation and then to do a quick B Scan to deter mine the range of the back wall ...

Страница 15: ...0PE users are recommended by Proceq to register for the Advanced Ultrasonic Tomography Applications training Details can be found on the Proceq website Preparation Very few preparations are necessary when measuring with the Pulse Echo Transducer The dry contact transducer means that acoustic coupling is ensured without the use of any couplant The contacts are sprung and can accommodate surface irr...

Страница 16: ...elength is 50 mm This means that anomalies smaller than 25 mm will be invisible Effect of sample size The geometry of the object is very important for obtaining good results The maximum penetration depth depends on the quality of the con crete and also on the amount of rebars present Typically the maximum transmission depth lies between 50 cm 19 7 and 1m 39 4 Generally the minimum lateral dimensio...

Страница 17: ...n PL Link once the files have been downloaded to a PC 5 Ordering Information 5 1 Units PART NO DESCRIPTION 327 10 002 Pundit Touchscreen without transducers Consisting of Pundit Touchscreen BNC adapter cable power supply USB cable DVD with software docu mentation carrying strap and carrying case 327 10 001 Pundit PL 200 Consisting of Pundit Touchscreen 2 Transducers 54 kHz 2 BNC cables 1 5 m coupl...

Страница 18: ... reliable and accurate measurements the instru ment should be calibrated on a yearly basis The customer may however determine the service interval based on his or her own experience and usage Do not immerse the instrument in water or other fluids Keep the housing clean at all times Wipe off contamination using a moist and soft cloth Do not use any cleaning agents or solvents Do not open the housin...

Страница 19: ...ime format to be used Connecting to a Pundit Touchscreen Unit Connect the Pundit Touchscreen Unit to a USB port then select the fol lowing icon to download data from the Pundit Touchscreen Unit The following window will be displayed Select USB as the communica tion type Select one or more measurements and click Download Click on Next When a Pundit Touch screen Unit has been found its details will ...

Страница 20: ...etween folders by using cut and paste functionality Right click on a measurement or a folder to see the options available 7 2 1 Area Scan When the 1 1 check box is ticked it is possible to zoom in and out of the scan using the mouse wheel Click with the right mouse button to move the cursor to a new position Drag with the left mouse button pressed to move within the zoomed graphic Click on the Sym...

Страница 21: ...dragging with the left mouse button Move the A Scan in the y direction by dragging with the left mouse button Drag the cross hairs to a point of interest using the right mouse button The position is shown in the details on the right hand side The current A Scan e g 22 is indicated in the table Adjusting the date and time Right click in the Date Time column The time will be adjusted for the selecte...

Страница 22: ...bmp or jpg 7 6 Further Functions The following menu items are available via the icons at the top of the screen PQUpgrade icon Allows you to upgrade your firmware via the internet or from local files Open project icon Allows you to open a previously saved pql project Save project icon Allows you to save the current project Print icon Allows you to print out the project You may select in the printer...

Страница 23: ...Industrial Road 02 02A Morningstar Centre Singapore 536202 Phone 65 6382 3966 Fax 65 6382 3307 info asia proceq com Proceq Rus LLC Ul Optikov 4 korp 2 lit A Office 410 197374 St Petersburg Russia Phone Fax 7 812 448 35 00 info russia proceq com Proceq Middle East P O Box 8365 SAIF Zone Sharjah United Arab Emirates Phone 971 6 557 8505 Fax 971 6 557 8606 info middleeast proceq com Proceq SAO Ltd So...