background image

 

 

 

                                                                                                                                        

 PRODMHD11 Manual V1.1

 

SAFETY PRECAUTIONS

 

 

The presence of this symbol is to alert the installer and user to the presence of uninsulated 
dangerous voltages within the product’s enclosure that may be of sufficient magnitude to produce 
a risk of electric shock. 

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS DEVICE TO RAIN OR 
MOISTURE. DO NOT OPEN THE UNIT. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. 

 

 

DO NOT apply power to the unit until all connections have been made, all components have been installed and 
all wiring has been properly terminated. 

 

DO NOT terminate, change or uninstall any wiring without first disconnecting the unit’s power adapter from the 
device. 

 

This device is supplied with the appropriately rated 12VDC power supply with the centre pin positive.  The use of 
any other power supply could cause damage and invalidate the manufacturer’s warranty. 

 

DO NOT power on the unit until all cables and connections to the device have been properly connected.  

 

The  device  should  be  installed  in  an  environment  consistent  with  its  operating  temperature  specifications. 
Placement next to heating devices and ducts is to be avoided as doing so may cause damage. The device should 
not be placed in areas of high humidity. 

 

DO NOT cover any of the device’s ventilation openings. 

 

If the device has been in a cold environment allow it to warm to room temperature for at least 2 hours before 
connecting power

.  

 

 

 

 

PACKAGE CONTENTS

 

This package contains: 

 

 

One PRODMHD11 HD Encoder/Modulator 

 

One Adapter 

 

One installation/configuration manual 

 

Inspect the package before starting installation to ensure there is no damage and all supplied contents are present. 
Contact your distributor or dealer should the device be damaged or package contents are incomplete.

 

Содержание PRODMHD11

Страница 1: ...INSTALLATION CONFIGURATION MANUAL PRODMHD11 Single HD Encoder Modulator BLAKE U K LTD 177 187 Rutland Road Sheffield S3 9PT UK TEL 0114 275 9729 FAX 0114 275 6061 https www blake uk com...

Страница 2: ...ESCRIPTION 4 FEATURES 4 SPECIFICATIONS 5 INSTALLATION 6 UNPACKING and INSPECTION 6 HARDWARE INSTALLATION and CONNECTIONS 6 MODULATOR SETUP AND CONFIGURATION 7 INITIAL SETUP TO FACTORY DEFAULT 7 MODULA...

Страница 3: ...tive The use of any other power supply could cause damage and invalidate the manufacturer s warranty DO NOT power on the unit until all cables and connections to the device have been properly connecte...

Страница 4: ...signal into a flexible DVB T Multiplex HDMI inputs with HDMI loop through Video resolution up to 1080p Clean and clear picture of high motion video sports and text crawls rolls etc Programmable via LC...

Страница 5: ...p Video Compression H 264 AVC Audio Compression MPEG1 Layer II AAC LCN Yes Carrier OFDM Mode 2K 8K Guard Intervals 1 32 Code Rate FEC 7 8 Constellations QAM64 GENERAL Power Supply 12 VDC 1 5 Amp Consu...

Страница 6: ...if there is any indication of defect or damage HARDWARE INSTALLATION and CONNECTIONS 1 Use a HDMI cable to connect the video source e g CATV DVD VCR Camera to the unit s HDMI IN port It is highly rec...

Страница 7: ...tup Channel number and LCN For switching between the two parameters press OK button until the arrow flashes Press UP DOWN button to select the desired setup parameter Then press OK again to confirm Ou...

Страница 8: ...same time turn ON the unit Release the UP and DOWN buttons when the LCD shows Reset To Default The unit will reset to factory default Caution Once this process is complete the unit will automatically...

Страница 9: ...ed LAN setup 1 Power up the Encoder Connect each encoder using a standard CAT5e cable from the Web Management port located on the rear panel of the encoder to a switch Connect a CAT5e cable from the s...

Страница 10: ...al V1 1 10 4 Select Local Area Connection Icon Then Right Click Select Properties Internet Protocol Version 4 TCP IPv4 Properties 5 Select Obtain an IP address automatically Obtain DNS server address...

Страница 11: ...automatically Select Start Computer Network 7 After selecting Network the encoders will show up on the right side under Media Devices Each device will show up by Device Address ex PROCEPTION 001 002 0...

Страница 12: ...8 Welcome page will be displayed as shown figure for example 9 Select the Common Setup tab User will be presented with encoders Authentication Required screen 10 Enter User Name and Password User Name...

Страница 13: ...PRODMHD11 Manual V1 1 13 11 Common Setup Remark The Attenuation in the Common Setup is reserved Please adjust the attenuation by adjusting the Gain control from the unit...

Страница 14: ...PRODMHD11 Manual V1 1 14 12 RF Setup...

Страница 15: ...PRODMHD11 Manual V1 1 15 13 Encoder Setup...

Страница 16: ...PRODMHD11 Manual V1 1 16 14 Network Setup...

Страница 17: ...PRODMHD11 Manual V1 1 17 15 Administration...

Страница 18: ...WS 8 SETTINGS Windows 8 Settings If using Windows 8 PC move the mouse to the bottom or top right corner of the screen and select Settings Select Control Panel In the Control Panel window select Catego...

Страница 19: ...PRODMHD11 Manual V1 1 19 Select Network and Sharing Centre Select Change Adapter Settings Right click on your connected network and select Properties...

Страница 20: ...Properties Select Use the following IP address and Use the following DNS server addresses to change your computer s IP address and or DNS server addresses To get IP settings automatically using DHCP...

Страница 21: ...PRODMHD11 Manual V1 1 21 PRODMHD11 HD Encoder Modulator Notes PRODUCT NOTES ITEM VALUE DEVICE NAME PURCHASE DATE INSTALLATION DATE SERIAL NUMBER FIRMWARE VERSION...

Отзывы: