Maintenance
52400046 / 52400048
49 / 58
Maintenance task
Daily
Weekly
Monthly
Every six
months
Yearly
ble, and can be accessed by personnel.
Check the charge level of the battery.
X
X
Check the condition of the battery.
See the operating instructions for the battery in the appendix.
Check that the charging device is working
properly.
See the charging
device’s operating instructions in the appendix.
Check the electrical installation and cable
screw unions.
X
Check electrical vacuum generation.
See the vacuum generator operating instructions in the appendix.
9.4 Inspecting Safety Features
CAUTION
Risk of injury from falling objects!
During all suction tests, only apply suction to the load. Do not lift it.
•
If operation is interrupted, check the safety features at the beginning of each shift.
•
For continuous shift operation, check the safety features once a week.
9.4.1 Inspecting the gauge
Switch on the vacuum generator.
A warning signal sounds.
When the minimum required vacuum of -0,6 bar is reach, the warning signal shuts off.
The safety feature is working correctly.
9.4.2 Testing the Warning Device
1. Switch on the vacuum generator.
2. Place the lifting device on a load with a smooth, airtight surface, e.g. a metal sheet.
A warning signal sounds until the working vacuum of -0,6 bar is reached.
3. Press the
Pick up load
(12.2) button.
4. Once the vacuum is established, create a leak on the sealing lip.
The vacuum shown on the gauge will decrease.
When the vacuum falls below the minimum vacuum of -0,6 bar, the warning signal must sound.
•
If the lifting device has a second vacuum circuit, repeat this test on the second vacuum circuit.
•
The alarm threshold of the warning device is set for the lifting device at the factory. Never adjust the alarm thresh-
old.
9.4.3 Checking Vacuum Hoses and Hose Clamps
1. Check the vacuum hoses for wear.
2. Replace damaged vacuum hoses (chafe marks, breaks, kinks, etc.).
Содержание SH-2500-UNI-GL
Страница 1: ...52400046 52400048 V2 DE GB Betriebsanleitung Operating Instructions SH 2500 UNI GL SH 2500 UNI GL FFS...
Страница 3: ......
Страница 4: ......
Страница 58: ...5240 0046 5240 0048 54 54...
Страница 78: ......
Страница 101: ...Transport and storage 52400046 52400048 23 58 See the operating instructions for the battery in the appendix...
Страница 134: ...52400046 52400048 56 58...
Страница 135: ...57 58 52400046 52400048...
Страница 136: ...52400046 52400048 58 58...
Страница 140: ......
Страница 141: ...Ersatz und Verschlei teile...