Operation
13 / 14
58500009/58500010/58500011
V3
GB
4.3.6
Starting up
•
Slide the ON-OFF switch
①
to the ON position to turn on the unit (FXAH-120).
•
The battery status indicator
②
below the power switch lights up to indicate the battery charge level.
•
If the battery status indicator
②
flashes, the battery
⑥
is not sufficiently charged and should be
recharged before using the device, or replaced with a charged battery.
•
Working with the device when the battery is low can lead to injuries and damage to materials!
•
Position the device (FXAH-120) on the surface to be lifted.
•
To switch on the vacuum pump and trigger surface suction, the green button
③
must be pressed.
Suction is performed in a matter of seconds.
•
If the sucked material is to be released again, the red button
④
must be pressed to release it.
•
The manometer
⑤
must be constantly in the operator's field of vision, especially with slightly porous
materials. If the display shows less than - 0.7 bar (- 10 psi), discard material immediately!