Displacement 163
cm
3
Max. power:
4,77 KW / 6,5 hp
Fuel:
normal unleaded petrol
Tank capacity:
15,0 l
Weight: 44
kg
LWA sound power level:
97 dB(A)
Sound pressure level LWM:
92 dB(A)
Spark plug:
NGK BPR5ES
STE 3500
Generator Synchronous
Protection type:
IP 23
Continuous power S1:
2800 W
Maximum power S2 5 min.:
3100 W
Rated voltage:
2x230 V / 1
Rated current:
Frequency: 50
Hz
Drive engine design
4-stroke, air-cooled
Displacement 173
cm
3
Max. power:
5,88 KW / 8 hp
Fuel:
normal unleaded petrol
Tank capacity:
25,0 l
Weight: 72
kg
LWA sound power level:
97 dB(A)
Sound pressure level LWM:
92 dB(A)
Spark plug:
NGK BPR5ES
12. Changing and checking the oil level
The engine oil is best changed when the engine is at
working temperature.
Use only engine oil (15W40).
Place the generator on a slightly inclined surface
so that the oil drain plug is at the lower end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine oil
drain out.
After the old oil has drained out, close the oil drain
plug and place the generator on a level surface
again
Fill in engine oil up to the top mark on the oil dip
stick
Important: Do not screw in the oil dip stick – only
insert it.
Dispose of the old oil properly.
13. Cleaning the air filter
Remove the cover from the air filter.
Now you can remove the filter elements.
Do not use abrasive cleaning agents or petrol to
clean the elements.
Clean the elements by tapping on a flat surface.
14. Troubleshooting
Fault
Engine does not start
Generator has too little or no
voltage
Cause
Automatic oil cut-out has not res-
ponded
No fuel
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air filter dirty
Remedy
Check the oil level, top up with
engine oil
Refuel
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter
GB
8
Anleitung PS 2300 SPK 1 28.07.2004 14:50 Uhr Seite 8