Safety

2

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see

this symbol on your pump or in this manual,

look for one of the following signal words and be
alert to the potential for personal injury.

warns about hazards that 

will 

cause

serious personal injury, death or major property
damage if ignored.

warns about hazards that 

can 

cause

serious personal injury, death or major property
damage if ignored.

warns about hazards that 

will 

or 

can

cause minor personal injury or property damage if
ignored.
The label 

NOTICE 

indicates special instructions

which are important but not related to hazards.

Carefully read and follow all safety instructions in
this manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

RULES FOR SAFE

INSTALLATION AND

OPERATION

Read the Owner’s Manual and Rules for Safe
Operation and Installation Instructions carefully.
Failure to follow these Rules and Instructions could
cause serious bodily injury and/or property dam-
age.
Install system according to local codes.
Always test water from well for purity before using.
Check your local health department for testing 
procedure.
Before installing or servicing your tank, BE SURE
pump electric power source is disconnected.
BE SURE your pump electrical circuit is properly
grounded.
Remove bleeder orifices, air volume controls or
other air charging devices in existing system.

To prevent possible serious or fatal

injury and/or damage to equipment, system pres-
sure must be less than 100 pounds per square inch
(PSI) under any circumstances. Failure to follow
this instruction can result in tank blowup. If sys-
tem discharge pressure can exceed 100 PSI, install
a relief valve capable of passing the full pump vol-
ume at 100 PSI.

Hazardous pressure. Read owner’s

manual before attempting to install, operate, or
service this tank. To avoid possible equipment fail-
ure, severe injury, and property damage, do not
allow pump, tank, or piping system to freeze.

LIMITED WARRANTY

PENTAIR WATER warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free
from defects in material and workmanship for the Warranty Period shown below.

Product

Warranty Period

Water Systems Products — jet pumps,

whichever occurs first:

small centrifugal pumps, submersible pumps

12 months from date of original installation, or

and related accessories

18 months from date of manufacture

Signature 2000

®

Fibrewound Tanks

5 years from date of original installation

Pro-Source Plus

TM

Fibrewound Tanks

5 years from date of original installation

Pro-Source

TM

Steel Pressure Tanks

5 years from date of original installation

Pro-Source

TM

Epoxy-Lined Tanks

3 years from date of original installation

Sump/Sewage/Effluent Products

12 months from date of original installation, or
18 months from date of manufacture

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper
installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power
through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient com-
pensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and PENTAIR WATER’s only duty, is that PENTAIR WATER repair or replace defective products (at PENTAIR
WATER’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service
through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the
Warranty Period has expired. This warranty is not transferable.

PENTAIR WATER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHAT-
SOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an
implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You
may also have other rights which vary from state to state.

This warranty supersedes and replaces all previous warranty publications.

PENTAIR WATER

293 Wright St., Delavan, WI  53115

TPS series tanks are identical

to PS series tanks except for

color. All parts are the same.

Содержание PS119-TR50

Страница 1: ... Steel PressureTanks 2005 1000000173 Rev 9 19 08 Installation Operation Parts For further operating installation or maintenance assistance Call 1 262 728 5551 PENTAIR WATER 293 Wright Street Delavan WI 53115 Steel Pressure Tank ...

Страница 2: ...ystems Products jet pumps whichever occurs first small centrifugal pumps submersible pumps 12 months from date of original installation or and related accessories 18 months from date of manufacture Signature 2000 Fibrewound Tanks 5 years from date of original installation Pro Source PlusTM Fibrewound Tanks 5 years from date of original installation Pro SourceTM Steel Pressure Tanks 5 years from da...

Страница 3: ...and 1B for typical installations of this kind OPERATING CYCLE 1 Tank nearly empty air expands filling area above vinyl water cell Fig 2A 2 Water begins to enter tank air is compressed above water cell as it fills with water Fig 2B 3 Pump up cycle completed air now com pressed to cut off setting of pressure switch Fig 2C 4 Water being drawn from tank compressed tank air forces water out of water ce...

Страница 4: ...eaks in the piping on the suction side of the pump 1 Lake Chemical Co Chicago Illinois TO CHECK TANK AIR CHARGE If drawdown amount of water that comes out of tank per pump cycle decreases significantly check as follows 1 To check air charge in tank shut off electric power to pump open faucet near tank and drain completely 2 At the air valve in top of tank check air pres sure with a standard tire g...

Страница 5: ...steps 2 through 5 under Testing For Water Cell Leakage above 3 Remove nuts from tank cover flange Tap cover flange to break seal and remove 4 Water cell will not come out in one piece Hold water cell with pliers and cut wherever conve nient with single edge razor blade or sharp knife Continue holding and cutting until water cell is removed 5 Clean and dry inside of tank 6 Before water cell can be ...

Страница 6: ...it on its side 6 Remove flange from tank 7 Push water cell into tank far enough so that you can get into tank with a dowel rod 8 Soap the outside of the new valve and mount it on the end of a piece of 1 4 or 5 16 dowel rod Push the valve up past the water cell into its mounting hole in the top of the tank Push it through as far as it will conveniently go leave the valve cap on to protect the threa...

Страница 7: ... Gal 19 Gal 1 Water Cell Vinyl 1 U20 7 U20 13 2 Cover Flange 1 U31 442P U31 446P 3 Flanged Nut 5 16 18 Hex 6 U36 202BT U36 202BT 4 Air Valve with Cap 1 U212 160B U212 160B 5 Air Valve Cover 1 U31 380P U31 380P REPAIR PARTS LIST Pro Source Tanks Not illustrated TPS series tanks are identical to PS series tanks except for color All parts are the same ...

Страница 8: ...BT U36 202BT U36 202BT Does not require Stand Pipe Does not require Stand Pipe Key Part No PS50 T50 PS62 T51 PS85 T52 PS119 TR50 No Description Used 50 Gal 62 Gal 85 Gal 119 Gal 1 Air Valve Cover 1 U31 380P U31 380P U31 380P U31 380P 2 Air Valve with Cap 1 U212 160B U212 160B U212 160B U212 160B 3 Water Cell Vinyl 1 U20 10 U20 14 U20 17 U20 20 4 Base 1 U31 512P U31 512P U31 512P U31 512P 5 Cover F...

Страница 9: ...r Pro Source 2005 1000000173 Rév 19 9 08 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 262 728 5551 Steel Pressure Tank PENTAIR WATER 293 Wright Street Delavan WI 53115 ...

Страница 10: ...pompes centrifuges pompes submersibles et 12 mois à compter de la date de la première installation ou tous les accessoires connexes 18 mois à compter de la date de fabrication Réservoirs en fibre de verre Signature 2000 5 ans à compter de la date de la première installation Réservoirs en fibre de verre ProSource PlusTM 5 ans à compter de la date de la première installation Réservoirs sous pression...

Страница 11: ... installations typiques de ce genre CYCLE DE FONCTIONNEMENT 1 Le réservoir est presque vide l air remplit la partie qui se trouve au dessus du membrane en vinyle Figure 2A 2 L eau commence à remplir le réservoir au fur et à mesure que le réservoir se remplit l air est com primé au dessus du membrane Figure 2B 3 Le cycle de pompage est terminé l air est com primé jusqu au réglage du manostat Figure...

Страница 12: ...té aspiration de la pompe 1 Lake Chemical Co Chicago Illinois POUR VÉRIFIER LA CHARGE D AIR DU RÉSERVOIR Si le soutirage la quantité d eau obtenue du réservoir par cycle de fonctionnement de la pompe diminue considérablement vérifier ce qui suit 1 Pour vérifier la charge d air du réservoir couper le courant électrique parvenant à la pompe ouvrir un robinet proche du réservoir et vider toute l eau ...

Страница 13: ...oser les écrous du couvercle du réservoir Taper sur le couvercle pour briser le joint puis le déposer 4 Le diaphragme sortira d un seul morceau Tenir le diaphragme avec des pinces et le couper dans un endroit pratique avec une lame de rasoir à un seul tranchant ou avec un couteau bien aiguisé Continuer à tenir le diaphragme et à le couper jusqu à ce qu il soit complètement enlevé 5 Nettoyer et séc...

Страница 14: ... le réservoir à l envers 6 Déposer la bride du réservoir 7 Pousser la vessie suffisamment loin dans le réser voir de façon à pouvoir atteindre l intérieur du résevoir avec une tige creuse 8 Enduire l extérieur de la valve neuve et la monter sur l extrémité d un morceau de tige creuse de 1 4 de pouce ou 5 16 de pouce Pousser la valve au delà de la vessie dans le trou de montage qui se trouve en hau...

Страница 15: ...inyl 1 U20 7 U20 13 2 Couronne de protection 1 U31 442P U31 446P 3 Écrou à bride 5 16 18 6 U36 202BT U36 202BT 4 Reniflard chapeau incl 1 U212 160B U212 160B 5 Bouchon de valve d air 1 U31 380P U31 380P LISTE DES PIÈCES DE RECHANGE Réservoirs Pro Source Non illustrée Les réservoirs de la série TPS sont identiques aux réservoirs de la série PS à l exception de la couleur Les pièces sont toutes les ...

Страница 16: ... 460P U231 461P U231 460P 6 Écrou à bride 5 16 18 6 U36 202BT U36 202BT U36 202BT U36 202BT No nécessite tuyau à pied No nécessite tuyau à pied Description No PS50 T50 PS62 T51 PS85 T52 PS119 TR50 Réf de la pièce utilisé 189 3 litres 234 7 litres 321 8 litres 450 5 litres 1 Bouchon de valve d air 1 U31 380P U31 380P U31 380P U31 380P 2 Reniflard chapeau incl 1 U212 160B U212 160B U212 160B U212 16...

Страница 17: ...ro Source 2005 1000000173 Rev 9 19 08 Installación Operación Repuestos Para obtener más asistencia con respecto a la operación la instalación o el mantenimiento Llamar al 1 262 728 5551 PENTAIR WATER 293 Wright Street Delavan WI 53115 Steel Pressure Tank ...

Страница 18: ...durante el Período de Garantía indicado a continuación Producto Período de Garantía Productos de sistemas de agua bombas de chorro lo que ocurra primero pequeñas bombas centrífugas bombas sumergibles 12 meses desde la fecha de la instalación inicial o y accesorios asociados 18 meses desde la fecha de fabricación Tanques de devanado de fibra de vidrio Signature 2000 5 años desde la fecha de la inst...

Страница 19: ...arán Consulte las Figuras No 1A y 1B para instala ciones típicas de este tipo CICLO DE OPERACIÓN 1 El tanque está casi vacío el aire expande el área de llenado por encima de la celda de agua vinílica Fig 2A 2 El agua comienza a entrar al tanque el aire se comprime por encima del agua a medida que se llena de agua Fig 2B 3 Se ha completado el ciclo de bombeo el aire ahora se ha comprimido a la grad...

Страница 20: ...Chicago Illinois VERIFICACIÓN DE LA CARGA DE AIRE DEL TANQUE Si la extracción la cantidad de agua que sale del tanque por ciclo de bombeo disminuye considerable mente verifique lo siguiente 1 Para verificar la carga de aire en el tanque cierre la llave de suministro de corriente eléctrica a la bomba abra el grifo cercano al tanque y drene completamente 2 A la altura de la válvula de aire en la par...

Страница 21: ...s en la celda de agua que antecede 3 Saque las tuercas de la brida de la cubierta del tanque Golpetee la brida de la cubierta para romper el sello y sacarla 4 La celda de agua no saldrá en una sola pieza Sostenga la celda de agua con alicates y corte en donde sea conveniente con una cuchilla de borde simple o con un cuchillo filoso Continúe soste niendo y cortando hasta que haya sacado la celda de...

Страница 22: ...un costado 6 Saque la brida del tanque 7 Empuje la celda de agua dentro del tanque lo sufi ciente como para poder alcanzar el interior del tanque con una barra de espiga 8 Enjabone el exterior de la nueva válvula y colóquela en el extremo de una barra de espiga de 1 4 o de 5 16 Empuje la válvula más allá de la celda de agua y dentro de su orificio de montaje en la parte superior del tanque Empújel...

Страница 23: ...ua vinilo 1 U20 7 U20 13 2 Brida de la cubierta 1 U31 442P U31 446P 3 Tuerca de reborde 5 16 18 Hex 6 U36 202BT U36 202BT 4 Válvula de aire con tapa 1 U212 160B U212 160B 5 Cubierta de la válvula de aire 1 U31 380P U31 380P LISTA DE PIEZAS DE REPUESTO Tanques Pro Source No se ilustra Los tanques de la serie TPS son idénticos a los tanques de la serie PS a excepción de su color Todas las piezas son...

Страница 24: ...2BT U36 202BT No requiere tubo ascendente Modeols PS19S T02 PS19T T02 PS32 T03 PS35 T05 PS50 T50 PS62 T51 PS85 T52 PS119 TR50 Clave Descripción Cantidad PS50 T50 PS62 T51 PS85 T52 PS119 TR50 No del repuesto usada 50 Galones 62 Galones 85 Galones 119 Galones 1 Cubierta de la válvula de aire 1 U31 380P U31 380P U31 380P U31 380P 2 Válvula de aire con tapa 1 U212 160B U212 160B U212 160B U212 160B 3 ...

Отзывы: