background image

 

To deflate the unit a valve is so equipped to release the air in the structure, 
allowing the shelter to deflate.    We suggest using the inflator/deflator 
to empty the air berm to minimize the packing volume. The unit can then 
be carefully folded and packed into the carrying bag supplied for safe 
transportation and storage.   
 

SHELTER DIAGRAMS 

 

 

 

AUXILIARY INFLATION 
VALUE (for air cylinder & air 
guard) 

ELECTRIC INFLATOR / 
DEFLATOR INLET AND DUMP 
VALVE:          push in and quarter 
turn clockwise to lock valve open. To 
deflate, push in and quarter turn 
counter clockwise to allow valve to pop 
up and close. 

SAFETY OVER PRESSURE 
VALVE 

REMOVABLE CANOPY

 

TIE DOWNS FOR FASTENING 
ROPES TO TIE SHELTER 
DOWN IN STRONG WINDS

 

SIDE DOOR

 

ENTRANCE / EXIT DOOR

 

INFLATABLE 
STRUCTURE

 

REMOVABLE FLOOR

 

Содержание 31238165

Страница 1: ...LY BEFORE ASSEMBLING YOUR PRO SAFE SHELTER CONTENTS INTRODUCTION 1 SAFETY INSTRUCTIONS 2 PRINCIPLES OF OPERATION 4 SHELTER PACKING LIST 6 SET UP SHELTERS 7 CONNECTING MULTIPLE SHELTERS 10 PRO SAFE SHO...

Страница 2: ...his is your first air inflatable Shelter for your own comfort and safety please ensure that you obtain handling and operation experience before assuming command of the unit Your PRO SAFE authorized di...

Страница 3: ...ay from landslides fire sources floods and other dangerous environments 4 When removing shelters from the carrying bag ensure there are no sharp objects or glass on the floor that might tear or punctu...

Страница 4: ...to inflate unit an operator must stand by at all times and immediately turn off compressed air source when the over pressure valve is activated as noted by the hissing sound of escaping air 9 When def...

Страница 5: ...t tear or puncture the inflatable structure Avoid dragging the unit over rough surfaces The use of a tarp groundsheet is strongly recommended for inexpensive protection and maximum longevity of the fl...

Страница 6: ...plied for safe transportation and storage SHELTER DIAGRAMS AUXILIARY INFLATION VALUE for air cylinder air guard ELECTRIC INFLATOR DEFLATOR INLET AND DUMP VALVE push in and quarter turn clockwise to lo...

Страница 7: ...ing bag 2 Electric inflator deflator 3 Air guard 4 Stakes bag 5 Stake qty Depending on the shelter size 6 Hammer 7 SCBA High Pressure Air inlet hose 8 Repair material swatches sliver blue white for ca...

Страница 8: ...on ground C The carrying bag is not to be dragged but lifted and carried by the number of personnel on sight coordinators deem appropriate D Place the unit to suit all site and incident requirements e...

Страница 9: ...g in the close position at this point Extend the hose of the inflator deflator so that it is straight Insert the sharp head nozzle of the inflator deflator into the valve opening press down and turn r...

Страница 10: ...LY turn off compressed air supply The pressure relief valve will close automatically when excess air has escaped from unit NOTE Never cover block the pressure relief valve as the unit may burst Allow...

Страница 11: ...ehicles CONNECTING MULTIPLE SHELTERS Position and unpack all the shelters in the selected configuration Inflate and secure each shelter Locate the Velcro attachments at the end of each entrance and co...

Страница 12: ...hould be in a straight line 3 Roll up the zipper door and fasten it by the door webbing 4 Pull the Velcro flag off the door 5 Locate the stitching line vertically which shows the center of the flag Co...

Страница 13: ...ng personnel On the outside of the shower two small holes will be found which are used for sprinkler and sewage fittings After the shower is inflated pay attention to the removable independent pool in...

Страница 14: ...ories such as air water heaters decon showers disconnect and remove all showers heating air cooling units and so forth from inside the shelter or in close proximity to 2 Wipe up any residual water ins...

Страница 15: ...2 Allow your air shelter to dry thoroughly in the shade before storing never in bright sunlight Store your air shelter in a cool flat and dry place with some air in the air chambers if possible 3 It i...

Страница 16: ...it all is as originally left Use the enclosed repair kit for small punctures Clean the fabric around the area to be repaired using MEK or acetone then re clean as before Apply a coat of glue to the da...

Страница 17: ...N VALVE LEAKS Valve may have dirt or dust contamination preventing valve spring from closing the valve completely Carefully LIFT center of valve with small blunt object and clean with high pressure co...

Страница 18: ...ours before fully re inflating and using the unit SEE DETAILS BELOW SMALL TEARS CUTS AND PUNCTURE REPAIRS DESCRIPTION Use the enclosed repair kit for small punctures Clean the fabric around the area t...

Страница 19: ...direct damages including any damages and loss of profits from any cause whatsoever No person has authority to change this warranty PRO SAFE warrants all new PRO SAFE products for a period of two 2 yea...

Страница 20: ...laim PRO SAFE shelters are offered with carrying bags designed to offer a basic method to move and transport the product from point A to B The bags may also provide basic product protection In such a...

Отзывы: