20
PBN5018b
E
N
G
L
IS
H
FUNCTIONAL DESCRIPTION
A Nail aperture
B Trigger
C Exhaust air opening
D Rubber hand grip sleeve
E Fixed magazine
F Quick-connect air fitting
G Magazine lock
H Sliding magazine
I
Magazine sight gauge
OPERATING PROCEDURES
UNPACkING THE TOOL
Check and make sure each of the following is included.
Tool case
Nailer
2 hexagonal (Allen) keys
Small bottle of air tool oil
Air fitting
Operating instructions
SETUP
AIR SOURCE
The PRO-PULSE nailer is designed to operate on clean, dry, compressed
air, regulated at 60-100 PSI. The preferred system would include a filter (M,
fig.2), a pressure regulator (O, fig.2), and an automatic oiler (L, fig.2) located
as close to the tool as possible. Within 15 feet (5 metres) is ideal. The air
compressor must be able to maintain a minimum of 60 PSI kPa) when the
tool is being used. An inadequate air supply may cause a loss of power and
inconsistent driving
Use 3/8” (10 mm) I.D. air hoses. Use 1/2” (13 mm) I.D. air hoses for 50’
(15 m) runs or longer.