troUBLe SHootinG
The following form lists the common operating system with
problem and solutions. Please read the from carefully and follow it.
WarninG: if any of the following symptoms appears during your
operating. Stop using the tool immediately, or serious personal
injury could result. only a qualified persons or an authorized
service center can perform repairs or replacement of tool.
Disconnect tool from air supply before attempting repair or
adjustment. When replacing O-rings or Cylinder lubricate with air
tool oil before assembly.
problem(s)
possible
cause(s)
Suggested solution(s)
Tool runs at
normal speed
but loses
power under
load.
Motor parts
worn.
• Have a qualified technician
replace worn parts.
Tool runs
slowly.
Air flows
slightly from
exhaust.
Motor parts
jammed with
dirt particles.
• Check air inlet filter for
blockage.
• Pour air tool lubricating
oil into air inlet as per
instructions.
• Operate tool in short bursts
quickly reversing rotation
back and forth where
applicable.
• Repeat above as needed.
If this fails return to service
center.
Air flow
blocked by dirt.