16
For technical questions call 1-800-665-8685
V 3.0
Reciprocating Air Saw
8344129
problem(s)
possible
cause(s)
Suggested solution(s)
Tools will not
run.
Air flows
freely from
exhaust.
O-rings throttle
valve dislodged
from seat inlet
valve.
• Pour air tool lubricating
oil into air inlet as per
instructions.
• Operate tool in short bursts
of forward and / or reverse
rotation where applicable.
• Tap motor housing gently
with plastic mallet.
• If tool remains jammed return
to service centre.
Tool will not
shut off.
O-rings throttle
valve dislodged
from seat inlet
valve.
• Have a qualified technician
replace the O-ring.
Loss of power
or erratic
performance.
Excessive drain
on the air line.
Moisture or
restriction in
the air hose.
Incorrect size
or type of hose
connectors.
• Check the air supply.
• If tool is not corrected to
a 1/4 in. line, connect it
properly.
note:
Repairs should be carried out by a qualified person