Depósito legal y copyright 2015. Todos los derechos reservados.
11
PRO LIFTS S.L.
Quick operation guide
ENGLISH
spiral of the crank, and the sections.
5.3 -
All lifts should undergo an annual
technical inspection carried out by an
authorized VMB dealer to check the cer
-
tifications and general condition of all the
lift’s elements and security systems invol-
ved in the lift’s use.
5.4 -
Only use original spare parts to gua-
rantee a continued security level. The
user loses all rights to warranty if any spa-
re parts other than originals are used or
carries out any modification or alteration
to the towerlift.
5.5 -
To request a spare part please in-
dicate the corresponding code which can
be found in this manual together with the
lift’s serial number and year of manufac-
ture.
6. GUARANTEE.
The warranty period for this lift is 2 years
from the date of purchase.
PRO LIFTS S.L. promises, that from the
date of purchase and during the warranty
period to resolve any faults that may oc-
cur, produced through defect material or
fabrication. Damage caused by improper
use, product modification, third party ma
-
nipulation or accidental fire are not cove
-
red by this warranty.
If you release your finger from the ALS
lock it will automatically block. In this
case, repeat the first operation by turning
slightly clockwise (
N
1
) and then anti-cloc-
kwise (
N
2
) whilst always pulling the red
ALS lock out. It is necessary to completely
lower each profile before starting to lower
the next.
DO NOT
pull another red ALS
lock without having completely lowered
the previous profile.
4.10 - Transport:
For the transport of the tower is necessary
to fold the machine lowering every profile
completely. Once the towerlift is comple-
tely folded, place the legs and the struts
(
A
) in their transport compartment (
S
),
and tighten the transport knobs (
K
), then
the lift will be ready to be transported.
5. MAINTENANCE.
5.1 -
Regularly check the state of the ca
-
ble. If the cable has broken threads, or if
it shows any signs of crushed/flattened
areas, it should be changed and replaced
immediately with a new one. Do not use
the lift if the cables are in bad condition.
Only use VMB steel cables reference: DIN
3060 torsion resistant.
5.2 -
The lift is supplied from the factory
completely greased. However, it is recom-
mended to periodically grease according
to use, the gearing, the axis bearings, the