33
I nspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in. If lines appear in the
console display, see HOW TO CHANGE CONSOLE
SETTINGS on page 30 and adjust the contrast level
of the display.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 26.
If the console does not display your heart rate
when you use the chest heart rate monitor, see
TROUBLESHOOTING on page 18.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, press and
hold the fan decrease button for several seconds until
the test mode appears in the display.
Press the fan decrease button again. Then, press the
Quick Ramp increase or decrease button to calibrate
the ramp. The ramp will move upward and downward
as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the fan decrease button repeatedly to exit
the calibration mode.
HOW TO GREASE THE ROLLERS
See the EXPLODED DRAWING near the end of this
manual. If the Rollers (51) squeak when moving on
the Tracks (16), apply a small amount of white marine
grease equally to each Roller. Spread the grease
evenly around the Rollers. Pedal the elliptical until a
thin
lm of grease is distributed along the Tracks; then,
wipe off any excess grease.
MAINTENANCE AND TROUBLESHOOTING
FCC INFORMATION
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC CAUTION: To assure continued compliance, use only shielded interface cables when connecting to
computer or peripheral devices. Changes or modifications not expressly approved by the party respon-
sible for compliance could void the user’s authority to operate this equipment.
Содержание 1110 E Elliptical
Страница 4: ...4 ...
Страница 5: ...5 all STANDARD SERVICE PLANS ...