background image

4

External Interfaces

• This ST unit’s serial interface is not isolated.When the host (PLC) unit is also not iso-

lated, and to reduce the risk of damaging the RS232C/RS422/RS485 circuit, be sure 
to connect pin #5 SG (Signal Ground) terminal.

• Similarly shaped connectors are used for COM1 and COM2 of the ST. Therefore, be 

sure to connect the correct connectors. Communication is not available unless the 
connectors are connected correctly.

• When isolation is necessary, you can use the RS232C isolation unit (CA3-ISO232-01) on 

COM1.

„

COM1

Recommended Cable Connector XM2D-0901 <made by OMRON Corp.>

Recommended Jack Screw

XM2Z-0073 <made by OMRON Corp.>

Recommended Cable Cover

XM2S-0913 <made by OMRON Corp.>

Interfit Bracket

#4-40 inch screws are used.

Pin #

RS232C

Signal Name

Meaning

1

CD

Carrier Detect

2

RD(RXD)

Receive Data

3

SD(TXD)

Send Data

4

ER(DTR)

Data Terminal Ready

5

SG

Signal Ground

6

DR(DSR)

Data Set Ready

7

RS(RTS)

Request to Send

8

CS(CTS)

Clear to Send

9

CI(RI)/VCC

Called status display/
+5V±5% Output 0.25A

*1

*1 The RI/VCC selection for Pin #9 is switched via software. The VCC output is not protected against 

overcurrent. To prevent damage or unit malfunctions, use only the rated current.

Shell

FG

Frame Ground 
(Common with SG)

Содержание ST-3400 Series

Страница 1: ...with special attention to quality However should you find anything damaged or missing please contact your local ST distributor immediately About the Manual For the detailed information on ST3000 serie...

Страница 2: ...tion distance 5m E Serial Interface COM1 Dsub 9 pin plug type RS232C is supported F Serial Interface COM2 Dsub 9 pin plug type RS422 RS485 1 is supported 1 RS485 is compliant with ST 3400 series units...

Страница 3: ...mA for 1minute between charging and FG terminals Insulation Resistance DC500V 10M min between charging and FG terminals Physical Surrounding Air Temperature 0 to 50 C Storage Temperature 20 to 60 C Am...

Страница 4: ...2 01 on COM1 COM1 Recommended Cable Connector XM2D 0901 made by OMRON Corp Recommended Jack Screw XM2Z 0073 made by OMRON Corp Recommended Cable Cover XM2S 0913 made by OMRON Corp Interfit Bracket 4 4...

Страница 5: ...inch screws are used Pin RS422 RS485 1 1 RS485 is compliant with ST 3400 series units with revision code A or later Revision page 11 Signal Name Meaning 1 RDA Receive Data A 2 RDB Receive Data B 3 SDA...

Страница 6: ...tallation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the ST unit and then place the ST unit into the Panel from the front I...

Страница 7: ...ble Power Cord Specifications Use copper conductors only Power Connector Plug Specifications The power connector plug is CA5 DCCNM 01 made by Pro face or MSTB2 5 3 ST 5 08 made by Phoenix Contact Inse...

Страница 8: ...e bundled with or kept close to main circuit lines high voltage high current or input output signal lines To reduce noise make the power cord as short as possible If the supplied voltage exceeds the S...

Страница 9: ...ire with a thicker wire and place it in a duct 4 Input Output Signal Line Cautions All ST Input and Output signal lines must be separated from all operating circuit power cables If this is not possibl...

Страница 10: ...wing items when building the ST into an end use product The ST unit s rear face is not approved as an enclosure When building the ST unit into an end use product be sure to use an enclosure that satis...

Страница 11: ...o higashi Suminoe ku Osaka 559 0031 JAPAN TEL 81 0 6 6613 3116 FAX 81 0 6 6613 5888 http www pro face com Copyright 2007 Digital Electronics Corporation All rights reserved 085893E AST3400 MT01E BTH 2...

Отзывы: