background image

8

When connecting the Power Cord, use the 
following items when performing wiring. 
(Items are made by Phoenix Contact.)

„

Connecting the ST Power Cord

(1) Confirm that the ST unit’s Power Cord is 

unplugged from the power supply.

(2) Strip the power cord, twist the 

conductor’s wire ends, insert them into 
the pin terminal and crimp the terminal. 
Attach the terminal to the power 
connector.

• Use a flat-blade screwdriver (Size 0.6 

X 3.5) to tighten the terminal screws.
The torque required to tighten these 
screws is 0.5 to 0.6 N

m [5-7Lb

In.].

• Do not solder the cable connection.

(3) Attach the Power connector (Plug) to the 

Power Connector.

2.

Power Supply Cautions

• Input and Output signal lines must be sepa-

rated from the power control cables for 
operational circuits.

• To improve the noise resistance, be sure to 

twist the ends of the power cord wires 
before connecting them to the Power con-
nector (Plug).

• The ST unit’s power supply cord should 

not be bundled with or kept close to main 
circuit lines (high voltage, high current), or 
input/output signal lines.

• To reduce noise, make the power cord as 

short as possible.

• If the supplied voltage exceeds the ST 

unit’s range, connect a voltage transformer.

• Between the line and the ground, be sure to 

use a low noise power supply. If there is an 
excess amount of noise, connect a noise 
reducing transformer.

• The temperature rating of field installed 

conductors: 75°C only.

• Use voltage and noise reducing trans-

formers with capacities exceeding 
Power Consumption value.

• Must be used with a Class 2 Power Supply. 

(24VDC)

• Connect a surge absorber to handle power 

surges.

• Be sure to ground the surge absorber 

(E1) separately from the ST unit (E2).
Select a surge absorber that has a 
maximum circuit voltage greater then 
that of the peak voltage of the power 
supply.

Recommended 
Driver

SZF 1-0.6x3.5 
(1204517)

Recommended 
Pin Terminals

AI 0.75-8GY (3200519)
AI 1-8RD (3200030)
AI 1.5-8BK (3200043)
AI 2.5-8BU (3200522)

Recommended 
Pin Terminal 
Crimp Tool

CRIMPFOX ZA 3 
(1201882)

Power Connector (Socket)

Power Connector (Plug)

FG

+

-

Lightening Surge Absorber

E1

E2

FG

ST

Содержание ST-3400 Series

Страница 1: ...with special attention to quality However should you find anything damaged or missing please contact your local ST distributor immediately About the Manual For the detailed information on ST3000 serie...

Страница 2: ...tion distance 5m E Serial Interface COM1 Dsub 9 pin plug type RS232C is supported F Serial Interface COM2 Dsub 9 pin plug type RS422 RS485 1 is supported 1 RS485 is compliant with ST 3400 series units...

Страница 3: ...mA for 1minute between charging and FG terminals Insulation Resistance DC500V 10M min between charging and FG terminals Physical Surrounding Air Temperature 0 to 50 C Storage Temperature 20 to 60 C Am...

Страница 4: ...2 01 on COM1 COM1 Recommended Cable Connector XM2D 0901 made by OMRON Corp Recommended Jack Screw XM2Z 0073 made by OMRON Corp Recommended Cable Cover XM2S 0913 made by OMRON Corp Interfit Bracket 4 4...

Страница 5: ...inch screws are used Pin RS422 RS485 1 1 RS485 is compliant with ST 3400 series units with revision code A or later Revision page 11 Signal Name Meaning 1 RDA Receive Data A 2 RDB Receive Data B 3 SDA...

Страница 6: ...tallation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the ST unit and then place the ST unit into the Panel from the front I...

Страница 7: ...ble Power Cord Specifications Use copper conductors only Power Connector Plug Specifications The power connector plug is CA5 DCCNM 01 made by Pro face or MSTB2 5 3 ST 5 08 made by Phoenix Contact Inse...

Страница 8: ...e bundled with or kept close to main circuit lines high voltage high current or input output signal lines To reduce noise make the power cord as short as possible If the supplied voltage exceeds the S...

Страница 9: ...ire with a thicker wire and place it in a duct 4 Input Output Signal Line Cautions All ST Input and Output signal lines must be separated from all operating circuit power cables If this is not possibl...

Страница 10: ...wing items when building the ST into an end use product The ST unit s rear face is not approved as an enclosure When building the ST unit into an end use product be sure to use an enclosure that satis...

Страница 11: ...o higashi Suminoe ku Osaka 559 0031 JAPAN TEL 81 0 6 6613 3116 FAX 81 0 6 6613 5888 http www pro face com Copyright 2007 Digital Electronics Corporation All rights reserved 085893E AST3400 MT01E BTH 2...

Отзывы: